Effect of sampling density and location on airflow rate measurements in a naturally ventilated pig barn with an outdoor exercise yard: A boundary layer wind tunnel study
Xuefei Wu , Sabrina Hempel , David Janke , Barbara Amon , Guoqiang Zhang , Jürgen Zentek , Thomas Amon , Qianying Yi
{"title":"Effect of sampling density and location on airflow rate measurements in a naturally ventilated pig barn with an outdoor exercise yard: A boundary layer wind tunnel study","authors":"Xuefei Wu , Sabrina Hempel , David Janke , Barbara Amon , Guoqiang Zhang , Jürgen Zentek , Thomas Amon , Qianying Yi","doi":"10.1016/j.biosystemseng.2025.104275","DOIUrl":null,"url":null,"abstract":"<div><div>An accurate ventilation rate estimation is the basis for developing ventilation strategies, optimising indoor air quality and determining pollutant emissions from livestock buildings. To accurately quantify the airflow rate of a novel naturally ventilated pig barn with an outdoor exercise yard, the influence of sampling density and location on the airflow rate measurement was studied. The experiment was conducted in a large atmospheric boundary layer wind tunnel by measuring the airflow velocity at the openings (the yard opening and the window of the indoor room) of a scaled pig barn model. Under four wind directions (0 <span><math><mrow><mo>°</mo></mrow></math></span>, 60 <span><math><mrow><mo>°</mo></mrow></math></span>, 120 <span><math><mrow><mo>°</mo></mrow></math></span>, and 180 <span><math><mrow><mo>°</mo></mrow></math></span>), the study evaluated four sampling densities distributed separately along the vertical or the lateral directions of the opening, different mesh-like sampling strategies, and airflow rate measurement with or without considering the edge effects of the opening. The results showed that: 1) Sampling densities distributed vertically and laterally along the yard opening, as well as those distributed vertically along the window, were significantly affected by wind directions (p < 0.05). 2) The mesh-like sampling strategy can ensure accurate measurement results with a difference ratio of less than 5 %. 3) Suitable sampling densities without considering the wall effect caused by the vertical edge of the opening can still support reliable airflow rate measurement. The results of this study contribute to developing the direct method of airflow rate measurements in naturally ventilated livestock buildings.</div></div>","PeriodicalId":9173,"journal":{"name":"Biosystems Engineering","volume":"259 ","pages":"Article 104275"},"PeriodicalIF":5.3000,"publicationDate":"2025-09-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biosystems Engineering","FirstCategoryId":"97","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1537511025002119","RegionNum":1,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"AGRICULTURAL ENGINEERING","Score":null,"Total":0}
引用次数: 0
Abstract
An accurate ventilation rate estimation is the basis for developing ventilation strategies, optimising indoor air quality and determining pollutant emissions from livestock buildings. To accurately quantify the airflow rate of a novel naturally ventilated pig barn with an outdoor exercise yard, the influence of sampling density and location on the airflow rate measurement was studied. The experiment was conducted in a large atmospheric boundary layer wind tunnel by measuring the airflow velocity at the openings (the yard opening and the window of the indoor room) of a scaled pig barn model. Under four wind directions (0 , 60 , 120 , and 180 ), the study evaluated four sampling densities distributed separately along the vertical or the lateral directions of the opening, different mesh-like sampling strategies, and airflow rate measurement with or without considering the edge effects of the opening. The results showed that: 1) Sampling densities distributed vertically and laterally along the yard opening, as well as those distributed vertically along the window, were significantly affected by wind directions (p < 0.05). 2) The mesh-like sampling strategy can ensure accurate measurement results with a difference ratio of less than 5 %. 3) Suitable sampling densities without considering the wall effect caused by the vertical edge of the opening can still support reliable airflow rate measurement. The results of this study contribute to developing the direct method of airflow rate measurements in naturally ventilated livestock buildings.
期刊介绍:
Biosystems Engineering publishes research in engineering and the physical sciences that represent advances in understanding or modelling of the performance of biological systems for sustainable developments in land use and the environment, agriculture and amenity, bioproduction processes and the food chain. The subject matter of the journal reflects the wide range and interdisciplinary nature of research in engineering for biological systems.