Anterior Segment Optical Coherence Tomography and Anterior Segment Optical Coherence Tomography Angiography After Bleb Forming Glaucoma Surgeries: A Systematic Review.

IF 5.6 2区 医学 Q1 OPHTHALMOLOGY
Martin Kallab, Alex S Huang, Matthias Bolz, Clemens A Strohmaier
{"title":"Anterior Segment Optical Coherence Tomography and Anterior Segment Optical Coherence Tomography Angiography After Bleb Forming Glaucoma Surgeries: A Systematic Review.","authors":"Martin Kallab, Alex S Huang, Matthias Bolz, Clemens A Strohmaier","doi":"10.1111/ceo.14602","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The bleb-forming surgical spectrum in open-angle glaucoma has recently been expanded by novel surgical approaches. Through a medical device implantation (Xen Gel Stent (XGI) or Preserflo Microshunt (PMI)), these procedures aim at more standardised aqueous humour shunting and an intra- and postoperative risk reduction. Postoperatively, however, XEN, PMI and trabeculectomy share their dependence on the proper function of the filtration bleb. This review summarises available literature on anterior segment optical coherence tomography (AS-OCT)- and AS-OCT angiography (AS-OCTA)-based bleb parameters with an emphasis on their association with bleb function.</p><p><strong>Methods: </strong>A systematic PubMed search was performed to identify the available evidence.</p><p><strong>Results: </strong>A total of 52 suitable reports were identified and are presented in a structured manner.</p><p><strong>Conclusion: </strong>The retrieved literature demonstrates that there exists a broad body of evidence for the use of AS-OCT and AS-OCTA after TE, XGI and PMI with the potential for AS-OCT and AS-OCTA enhanced follow-up plans. Their implementation in clinical routine is, however, currently impaired by highly variable and impractical study endpoints, lacking transferability of available evidence between different surgical procedures and missing evidence from prospective interventional trials.</p>","PeriodicalId":55253,"journal":{"name":"Clinical and Experimental Ophthalmology","volume":" ","pages":""},"PeriodicalIF":5.6000,"publicationDate":"2025-09-06","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical and Experimental Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/ceo.14602","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The bleb-forming surgical spectrum in open-angle glaucoma has recently been expanded by novel surgical approaches. Through a medical device implantation (Xen Gel Stent (XGI) or Preserflo Microshunt (PMI)), these procedures aim at more standardised aqueous humour shunting and an intra- and postoperative risk reduction. Postoperatively, however, XEN, PMI and trabeculectomy share their dependence on the proper function of the filtration bleb. This review summarises available literature on anterior segment optical coherence tomography (AS-OCT)- and AS-OCT angiography (AS-OCTA)-based bleb parameters with an emphasis on their association with bleb function.

Methods: A systematic PubMed search was performed to identify the available evidence.

Results: A total of 52 suitable reports were identified and are presented in a structured manner.

Conclusion: The retrieved literature demonstrates that there exists a broad body of evidence for the use of AS-OCT and AS-OCTA after TE, XGI and PMI with the potential for AS-OCT and AS-OCTA enhanced follow-up plans. Their implementation in clinical routine is, however, currently impaired by highly variable and impractical study endpoints, lacking transferability of available evidence between different surgical procedures and missing evidence from prospective interventional trials.

形成泡状青光眼手术后的前段光学相干断层扫描和前段光学相干断层血管造影:系统回顾。
背景:开角型青光眼的泡形成手术范围最近因新的手术入路而扩大。通过医疗器械植入(Xen凝胶支架(XGI)或Preserflo微分流器(PMI)),这些手术旨在实现更标准化的房水分流,并降低术中和术后风险。然而,术后XEN、PMI和小梁切除术都依赖于滤过泡的正常功能。本文综述了基于前段光学相干断层扫描(AS-OCT)和AS-OCT血管造影(AS-OCTA)的泡参数的现有文献,重点介绍了它们与泡功能的关系。方法:进行系统的PubMed检索,以确定现有证据。结果:共确定了52份合适的报告,并以结构化的方式呈现。结论:检索到的文献表明,在TE, XGI和PMI后使用AS-OCT和AS-OCTA存在广泛的证据,并且有可能成为AS-OCT和AS-OCTA增强随访计划。然而,它们在临床常规中的实施目前受到高度可变和不切实际的研究终点的影响,缺乏不同外科手术之间现有证据的可转移性,缺乏前瞻性介入试验的证据。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
7.60
自引率
12.50%
发文量
150
审稿时长
4-8 weeks
期刊介绍: Clinical & Experimental Ophthalmology is the official journal of The Royal Australian and New Zealand College of Ophthalmologists. The journal publishes peer-reviewed original research and reviews dealing with all aspects of clinical practice and research which are international in scope and application. CEO recognises the importance of collaborative research and welcomes papers that have a direct influence on ophthalmic practice but are not unique to ophthalmology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信