Initial Experience of Appendicular Fracture Fixation with Low Profile Titanium Alloy Locking Plates: A Retrospective Study of 30 Fractures.

IF 1.1 2区 农林科学 Q3 VETERINARY SCIENCES
David Rhys Treharne, Scott Rutherford
{"title":"Initial Experience of Appendicular Fracture Fixation with Low Profile Titanium Alloy Locking Plates: A Retrospective Study of 30 Fractures.","authors":"David Rhys Treharne, Scott Rutherford","doi":"10.1055/a-2686-4869","DOIUrl":null,"url":null,"abstract":"<p><p>This retrospective study assessed the complications and mid-term outcomes of osteosynthesis using the String of Pearls Low Profile (SOP-LP) plate system in cats and small dogs with appendicular fractures.Clinical data from April 2018 to June 2021, involving 30 fractures in 29 cases, were reviewed. Fractures were stabilized using either the 1.5-mm or 2.0-mm SOP-LP plate. Data included patient signalment, fracture description, repair method, intraoperative complications and short-term follow-up outcomes. Midterm follow-up was performed by telephone-based veterinary questionnaires.Of the 30 fractures, 3 had complications linked to the SOP-LP system. Overall, 7/30 had complications. Major complications (<i>n</i> = 6) included two implant failures, one implant-associated irritation and three Kirschner wire migrations. Implant failures (<i>n</i> = 2) were with the 1.5-mm plates stabilizing radius/ulna fractures in dogs weighing over 2.9 kg. Short-term radiographic follow-up demonstrated clinical or radiographic union in all cases. In all cases available (<i>n</i> = 18) for midterm follow-up, the function was found to be full or acceptable.The SOP-LP plate can be used successfully for a wide variety of fractures in cats and small dogs; however, careful case selection is required, particularly when using the 1.5-mm plate as a single implant in patients weighing over 3 kg.</p>","PeriodicalId":51204,"journal":{"name":"Veterinary and Comparative Orthopaedics and Traumatology","volume":" ","pages":""},"PeriodicalIF":1.1000,"publicationDate":"2025-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary and Comparative Orthopaedics and Traumatology","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1055/a-2686-4869","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

This retrospective study assessed the complications and mid-term outcomes of osteosynthesis using the String of Pearls Low Profile (SOP-LP) plate system in cats and small dogs with appendicular fractures.Clinical data from April 2018 to June 2021, involving 30 fractures in 29 cases, were reviewed. Fractures were stabilized using either the 1.5-mm or 2.0-mm SOP-LP plate. Data included patient signalment, fracture description, repair method, intraoperative complications and short-term follow-up outcomes. Midterm follow-up was performed by telephone-based veterinary questionnaires.Of the 30 fractures, 3 had complications linked to the SOP-LP system. Overall, 7/30 had complications. Major complications (n = 6) included two implant failures, one implant-associated irritation and three Kirschner wire migrations. Implant failures (n = 2) were with the 1.5-mm plates stabilizing radius/ulna fractures in dogs weighing over 2.9 kg. Short-term radiographic follow-up demonstrated clinical or radiographic union in all cases. In all cases available (n = 18) for midterm follow-up, the function was found to be full or acceptable.The SOP-LP plate can be used successfully for a wide variety of fractures in cats and small dogs; however, careful case selection is required, particularly when using the 1.5-mm plate as a single implant in patients weighing over 3 kg.

低轮廓钛合金锁定钢板固定阑尾骨折的初步经验:30例骨折的回顾性研究。
本回顾性研究评估了使用珍珠串低侧(SOP-LP)钢板系统治疗猫和小型犬阑尾骨折的并发症和中期结果。回顾2018年4月至2021年6月29例30例骨折的临床资料。使用1.5 mm或2.0 mm的SOP-LP钢板稳定骨折。数据包括患者信号、骨折描述、修复方法、术中并发症和短期随访结果。中期随访采用电话兽医问卷。在30例骨折中,3例发生与SOP-LP系统相关的并发症。总的来说,7/30有并发症。主要并发症(n = 6)包括2例种植体失败,1例种植体相关刺激和3例克氏针移位。在体重超过2.9 kg的犬中,1.5 mm钢板固定桡骨/尺骨骨折失败(n = 2)。短期放射学随访显示所有病例临床或放射学愈合。在所有可进行中期随访的病例(n = 18)中,发现功能完全或可接受。SOP-LP钢板可成功用于猫和小型犬的各种骨折;但是,需要仔细选择病例,特别是在体重超过3kg的患者使用1.5 mm钢板作为单个植入物时。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
2.00
自引率
15.40%
发文量
49
审稿时长
18-36 weeks
期刊介绍: Veterinary and Comparative Orthopaedics and Traumatology (VCOT) is the most important single source for clinically relevant information in orthopaedics and neurosurgery available anywhere in the world today. It is unique in that it is truly comparative and there is an unrivalled mix of review articles and basic science amid the information that is immediately clinically relevant in veterinary surgery today.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信