Clinical performance, accuracy, and physical-mechanical properties of 3D-printed removable partial denture metal frameworks compared with conventionally and partially digitally produced frameworks: A systematic review.

IF 3.4 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Journal of prosthodontic research Pub Date : 2026-04-13 Epub Date: 2025-09-03 DOI:10.2186/jpr.JPR_D_25_00028
Ahmed Yaseen Alqutaibi, Redhwan Saleh Al-Gabri, Anas Saeed Al-Zaghruri, Ahmed E Farghal, Ahmed A Alnazzawi, Mohammed Ahmed Alghauli
{"title":"Clinical performance, accuracy, and physical-mechanical properties of 3D-printed removable partial denture metal frameworks compared with conventionally and partially digitally produced frameworks: A systematic review.","authors":"Ahmed Yaseen Alqutaibi, Redhwan Saleh Al-Gabri, Anas Saeed Al-Zaghruri, Ahmed E Farghal, Ahmed A Alnazzawi, Mohammed Ahmed Alghauli","doi":"10.2186/jpr.JPR_D_25_00028","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This systematic review evaluated the clinical performance, physical-mechanical properties, and accuracy of removable partial denture (RPD) frameworks fabricated using three-dimensional (3D) printing technologies-specifically, selective laser sintering (SLS), selective laser melting (SLM), and direct metal laser sintering (DMLS)-compared to those produced by conventional casting or methods using a partial digital workflow.</p><p><strong>Study selection: </strong>Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 guidelines, a literature search was conducted in the PubMed, Scopus, Web of Science, and Cochrane databases in October 2024. Studies were included if they compared the fit, accuracy, mechanical and physical properties, and clinical outcomes of metal RPD frameworks made using 3D printing technologies with those produced using conventional casting or partial digital methods. The risk of bias was assessed using appropriate tools (modified CONSORT, ROB2, and ROBINS-I) based on the study design and a qualitative analysis was conducted. This study received no funding and was registered with PROSPERO (#CRD42024597225).</p><p><strong>Results: </strong>Thirty studies were included: 12 compared 3D printing technologies with conventional casting, eight with partial digital methods, and 10 with both. Clinically, 3D-printed frameworks could improve retention and patient satisfaction. The laboratory results showed higher density, better mechanical properties (yield strength, surface roughness, and microhardness), and varied accuracy by component and method, with SLM and DMLS often outperforming conventional casting. The evidence was limited by methodological variability, a moderate risk of bias in many studies, and inconsistencies across the study designs and parameters.</p><p><strong>Conclusions: </strong>3D-printed RPD metal frameworks demonstrated clinical accuracy and mechanical-physical performance comparable or superior to those of conventional and partially digital methods for RPD frameworks, with ongoing advances expected to further enhance their precision and clinical applicability.</p>","PeriodicalId":16887,"journal":{"name":"Journal of prosthodontic research","volume":" ","pages":"206-223"},"PeriodicalIF":3.4000,"publicationDate":"2026-04-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of prosthodontic research","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.2186/jpr.JPR_D_25_00028","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/9/3 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This systematic review evaluated the clinical performance, physical-mechanical properties, and accuracy of removable partial denture (RPD) frameworks fabricated using three-dimensional (3D) printing technologies-specifically, selective laser sintering (SLS), selective laser melting (SLM), and direct metal laser sintering (DMLS)-compared to those produced by conventional casting or methods using a partial digital workflow.

Study selection: Following the Preferred Reporting Items for Systematic Reviews and Meta-Analyses 2020 guidelines, a literature search was conducted in the PubMed, Scopus, Web of Science, and Cochrane databases in October 2024. Studies were included if they compared the fit, accuracy, mechanical and physical properties, and clinical outcomes of metal RPD frameworks made using 3D printing technologies with those produced using conventional casting or partial digital methods. The risk of bias was assessed using appropriate tools (modified CONSORT, ROB2, and ROBINS-I) based on the study design and a qualitative analysis was conducted. This study received no funding and was registered with PROSPERO (#CRD42024597225).

Results: Thirty studies were included: 12 compared 3D printing technologies with conventional casting, eight with partial digital methods, and 10 with both. Clinically, 3D-printed frameworks could improve retention and patient satisfaction. The laboratory results showed higher density, better mechanical properties (yield strength, surface roughness, and microhardness), and varied accuracy by component and method, with SLM and DMLS often outperforming conventional casting. The evidence was limited by methodological variability, a moderate risk of bias in many studies, and inconsistencies across the study designs and parameters.

Conclusions: 3D-printed RPD metal frameworks demonstrated clinical accuracy and mechanical-physical performance comparable or superior to those of conventional and partially digital methods for RPD frameworks, with ongoing advances expected to further enhance their precision and clinical applicability.

3d打印可移动局部义齿金属框架的临床性能、准确性和物理机械性能与传统和部分数字生产框架的比较:系统综述。
目的:本系统综述评估了使用三维(3D)打印技术(特别是选择性激光烧结(SLS),选择性激光熔化(SLM)和直接金属激光烧结(DMLS)制造的可摘局部义齿(RPD)框架的临床性能,物理力学性能和准确性,并与使用部分数字工作流程的传统铸造或方法生产的框架进行了比较。研究选择:根据系统评价和元分析2020指南的首选报告项目,于2024年10月在PubMed、Scopus、Web of Science和Cochrane数据库中进行文献检索。如果将使用3D打印技术制造的金属RPD框架与使用传统铸造或部分数字方法生产的金属RPD框架的契合度、精度、机械和物理性能以及临床结果进行比较,则将研究纳入其中。根据研究设计,使用适当的工具(改良的CONSORT、ROB2和ROBINS-I)评估偏倚风险,并进行定性分析。本研究未获得资助,已在PROSPERO注册(编号CRD42024597225)。结果:共纳入30项研究:12项比较3D打印技术与传统铸造技术,8项比较部分数字化方法,10项比较两者。临床上,3d打印框架可以提高患者的保留率和满意度。实验结果表明,SLM和DMLS具有更高的密度、更好的机械性能(屈服强度、表面粗糙度和显微硬度)以及不同组件和方法的不同精度,通常优于传统铸造。证据受到方法学可变性、许多研究中存在中等偏倚风险以及研究设计和参数不一致的限制。结论:3d打印RPD金属框架的临床准确性和机械物理性能与传统的和部分数字化的RPD框架方法相当或更好,并且有望进一步提高其精度和临床适用性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of prosthodontic research
Journal of prosthodontic research DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
6.90
自引率
11.10%
发文量
161
期刊介绍: Journal of Prosthodontic Research is published 4 times annually, in January, April, July, and October, under supervision by the Editorial Board of Japan Prosthodontic Society, which selects all materials submitted for publication. Journal of Prosthodontic Research originated as an official journal of Japan Prosthodontic Society. It has recently developed a long-range plan to become the most prestigious Asian journal of dental research regarding all aspects of oral and occlusal rehabilitation, fixed/removable prosthodontics, oral implantology and applied oral biology and physiology. The Journal will cover all diagnostic and clinical management aspects necessary to reestablish subjective and objective harmonious oral aesthetics and function. The most-targeted topics: 1) Clinical Epidemiology and Prosthodontics 2) Fixed/Removable Prosthodontics 3) Oral Implantology 4) Prosthodontics-Related Biosciences (Regenerative Medicine, Bone Biology, Mechanobiology, Microbiology/Immunology) 5) Oral Physiology and Biomechanics (Masticating and Swallowing Function, Parafunction, e.g., bruxism) 6) Orofacial Pain and Temporomandibular Disorders (TMDs) 7) Adhesive Dentistry / Dental Materials / Aesthetic Dentistry 8) Maxillofacial Prosthodontics and Dysphagia Rehabilitation 9) Digital Dentistry Prosthodontic treatment may become necessary as a result of developmental or acquired disturbances in the orofacial region, of orofacial trauma, or of a variety of dental and oral diseases and orofacial pain conditions. Reviews, Original articles, technical procedure and case reports can be submitted. Letters to the Editor commenting on papers or any aspect of Journal of Prosthodontic Research are welcomed.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信
小红书