Use of shunt-side esCCO monitoring for hemodynamic management during hemodialysis as a novel approach for early detection of hypotension: a report of two cases.

IF 1.3 4区 医学 Q4 ENGINEERING, BIOMEDICAL
Koji Nakai, Yuichi Hirate, Takeyuki Hiramatsu, Kazue Kojima, Yuika Wada, Takashi Nakajima, Aiko Nakai
{"title":"Use of shunt-side esCCO monitoring for hemodynamic management during hemodialysis as a novel approach for early detection of hypotension: a report of two cases.","authors":"Koji Nakai, Yuichi Hirate, Takeyuki Hiramatsu, Kazue Kojima, Yuika Wada, Takashi Nakajima, Aiko Nakai","doi":"10.1007/s10047-025-01526-7","DOIUrl":null,"url":null,"abstract":"<p><p>Early recognition of the signs of hypotension may lead to prompt intervention by medical professionals, reducing the risk of intradialytic hypotension. The study included two patients on dialysis, one with stable hemodynamics (Case 1) and one who developed hypotensive shock (Case 2), in whom noninvasive continuous hemodynamic monitoring using shunt-side estimated continuous cardiac output (esCCO) was performed. Noninvasive blood pressure (BP), heart rate, esCCO, estimated stroke volume, systemic vascular resistance, and decrease in blood volume of each patient before and after dialysis were evaluated in chronological order. In Case 1, esCCO decreased transiently with the decrease in blood volume, but with the adaptive change in heart rate and estimated stroke volume, the BP remained stable at the end. In Case 2, there was a rapid decrease in esCCO after the systemic vascular resistance compensation reached its limit, and esCCO decreased 30 min before a decrease in noninvasive BP became evident. These results indicate that shunt-side esCCO monitoring may detect signs of hypotension that cannot be detected using conventional BP monitoring systems. Monitoring using shunt-side esCCO may be a prospective method for intradialytic hemodynamic management.</p>","PeriodicalId":15177,"journal":{"name":"Journal of Artificial Organs","volume":" ","pages":""},"PeriodicalIF":1.3000,"publicationDate":"2025-09-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Artificial Organs","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10047-025-01526-7","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Early recognition of the signs of hypotension may lead to prompt intervention by medical professionals, reducing the risk of intradialytic hypotension. The study included two patients on dialysis, one with stable hemodynamics (Case 1) and one who developed hypotensive shock (Case 2), in whom noninvasive continuous hemodynamic monitoring using shunt-side estimated continuous cardiac output (esCCO) was performed. Noninvasive blood pressure (BP), heart rate, esCCO, estimated stroke volume, systemic vascular resistance, and decrease in blood volume of each patient before and after dialysis were evaluated in chronological order. In Case 1, esCCO decreased transiently with the decrease in blood volume, but with the adaptive change in heart rate and estimated stroke volume, the BP remained stable at the end. In Case 2, there was a rapid decrease in esCCO after the systemic vascular resistance compensation reached its limit, and esCCO decreased 30 min before a decrease in noninvasive BP became evident. These results indicate that shunt-side esCCO monitoring may detect signs of hypotension that cannot be detected using conventional BP monitoring systems. Monitoring using shunt-side esCCO may be a prospective method for intradialytic hemodynamic management.

使用分流侧esCCO监测血液透析期间的血流动力学管理作为早期发现低血压的新方法:两例报告。
早期识别低血压的迹象可能导致医疗专业人员及时干预,降低透析性低血压的风险。该研究包括两名透析患者,一名血液动力学稳定(病例1),另一名发生低血压休克(病例2),其中使用分流侧估计连续心输出量(esCCO)进行无创连续血液动力学监测。按时间顺序评估每位患者透析前后的无创血压(BP)、心率、esCCO、估计卒中容量、全身血管阻力和血容量下降。在病例1中,esCCO随着血容量的减少而短暂下降,但随着心率和估计卒中容量的适应性变化,BP最终保持稳定。在病例2中,esCCO在全身血管阻力代偿达到极限后迅速下降,esCCO在无创血压明显下降前30分钟下降。这些结果表明,分流侧esCCO监测可以检测到传统血压监测系统无法检测到的低血压迹象。使用分流侧esCCO进行监测可能是分析内血流动力学管理的前瞻性方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Artificial Organs
Journal of Artificial Organs 医学-工程:生物医学
CiteScore
2.80
自引率
15.40%
发文量
68
审稿时长
6-12 weeks
期刊介绍: The aim of the Journal of Artificial Organs is to introduce to colleagues worldwide a broad spectrum of important new achievements in the field of artificial organs, ranging from fundamental research to clinical applications. The scope of the Journal of Artificial Organs encompasses but is not restricted to blood purification, cardiovascular intervention, biomaterials, and artificial metabolic organs. Additionally, the journal will cover technical and industrial innovations. Membership in the Japanese Society for Artificial Organs is not a prerequisite for submission.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信