Intraocular Lens Position Stability During Phacovitrectomy with Air or Gas Tamponade.

Clinical ophthalmology (Auckland, N.Z.) Pub Date : 2025-08-15 eCollection Date: 2025-01-01 DOI:10.2147/OPTH.S539958
Yuji Yoshikawa, Takashi Matsushima, Shunichiro Takano, Jun Makita, Kei Shinoda
{"title":"Intraocular Lens Position Stability During Phacovitrectomy with Air or Gas Tamponade.","authors":"Yuji Yoshikawa, Takashi Matsushima, Shunichiro Takano, Jun Makita, Kei Shinoda","doi":"10.2147/OPTH.S539958","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To evaluate the stability of different intraocular lenses (IOLs) after phacovitrectomy with air or gas tamponade.</p><p><strong>Patients and methods: </strong>This retrospective cross-sectional study included 28 patients who underwent phacovitrectomy with air or sulfur hexafluoride gas tamponade and postoperative anterior segment optical coherence tomography assessments. Patients who received any DIB00V (Johnson & Johnson Surgical Vision, Inc. Irvine, CA, USA), XY-1 (HOYA Surgical Optics Co. Chromos, Singapore), or NX70s (Santen Pharmaceutical Co. LTD, Osaka, Japan) IOL implantation were analyzed. The anterior chamber depth (ACD) and IOL position values at each measurement (100%, 50%, 0%) and between IOLs were compared. The IOL displacement force (mN) was measured with a verification experiment and recorded at each 0.1 mm anterior movement until anterior displacement reached 0.5 mm.</p><p><strong>Results: </strong>The average patient age was 66 (59-73) years. ACD values increased progressively as the postoperative gas decreased for all IOLs. Compared to the preoperative ACD, postoperative ACD was significantly greater at 50% and 0% gas for all IOLs. The DIB00V had significantly larger ACD values than the XY-1 at 100% gas or air (P = 0.023) and the NX70s at 0% gas or air (P = 0.008). The IOL position gradually shifted significantly posteriorly for all IOLs as the gas or air disappeared. No significant change was observed in the DIB00V and NX70s between the gas 50% and gas 0% conditions (DIB00VP = 0.019 with Bonferroni correction, NX70s; P = 0.148 with Bonferroni correction). The DIB00V were significantly more posterior than the XY-1at 100% (P = 0.046).</p><p><strong>Conclusion: </strong>The DIB00V had greater IOL displacement force against push from the retinal surface compared to the XY-1 and NX70s and exhibited excellent z-axis stability in phacovitrectomy with air or gas tamponade.</p>","PeriodicalId":93945,"journal":{"name":"Clinical ophthalmology (Auckland, N.Z.)","volume":"19 ","pages":"2773-2783"},"PeriodicalIF":0.0000,"publicationDate":"2025-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12363976/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Clinical ophthalmology (Auckland, N.Z.)","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.2147/OPTH.S539958","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To evaluate the stability of different intraocular lenses (IOLs) after phacovitrectomy with air or gas tamponade.

Patients and methods: This retrospective cross-sectional study included 28 patients who underwent phacovitrectomy with air or sulfur hexafluoride gas tamponade and postoperative anterior segment optical coherence tomography assessments. Patients who received any DIB00V (Johnson & Johnson Surgical Vision, Inc. Irvine, CA, USA), XY-1 (HOYA Surgical Optics Co. Chromos, Singapore), or NX70s (Santen Pharmaceutical Co. LTD, Osaka, Japan) IOL implantation were analyzed. The anterior chamber depth (ACD) and IOL position values at each measurement (100%, 50%, 0%) and between IOLs were compared. The IOL displacement force (mN) was measured with a verification experiment and recorded at each 0.1 mm anterior movement until anterior displacement reached 0.5 mm.

Results: The average patient age was 66 (59-73) years. ACD values increased progressively as the postoperative gas decreased for all IOLs. Compared to the preoperative ACD, postoperative ACD was significantly greater at 50% and 0% gas for all IOLs. The DIB00V had significantly larger ACD values than the XY-1 at 100% gas or air (P = 0.023) and the NX70s at 0% gas or air (P = 0.008). The IOL position gradually shifted significantly posteriorly for all IOLs as the gas or air disappeared. No significant change was observed in the DIB00V and NX70s between the gas 50% and gas 0% conditions (DIB00VP = 0.019 with Bonferroni correction, NX70s; P = 0.148 with Bonferroni correction). The DIB00V were significantly more posterior than the XY-1at 100% (P = 0.046).

Conclusion: The DIB00V had greater IOL displacement force against push from the retinal surface compared to the XY-1 and NX70s and exhibited excellent z-axis stability in phacovitrectomy with air or gas tamponade.

Abstract Image

Abstract Image

Abstract Image

空气或气体填塞白内障玻璃体切除术中人工晶状体位置的稳定性。
目的:评价空气或气体填塞白内障玻璃体切除术后不同人工晶状体的稳定性。患者和方法:本回顾性横断面研究包括28例采用空气或六氟化硫气体填塞进行晶状体切除术的患者,并进行术后前段光学相干断层扫描评估。接受DIB00V (Johnson & Johnson Surgical Vision, Inc.)治疗的患者。对Irvine, CA, USA)、XY-1 (HOYA Surgical Optics Co. Chromos,新加坡)或NX70s (Santen Pharmaceutical Co. LTD, Osaka, Japan)人工晶状体植入术进行分析。比较每次测量时(100%、50%、0%)的前房深度(ACD)和人工晶状体位置值以及人工晶状体之间的差异。采用验证实验测量人工晶状体每前移0.1 mm至前移0.5 mm时的位移力(mN)。结果:患者平均年龄66(59 ~ 73)岁。所有人工晶状体的ACD值随着术后气体的减少而逐渐增加。与术前ACD相比,所有iol术后50%和0%气体的ACD显著增加。DIB00V在100%气体或空气条件下的ACD值明显大于XY-1 (P = 0.023)和nx70在0%气体或空气条件下的ACD值(P = 0.008)。随着气体或空气的消失,所有人工晶状体的位置逐渐向后明显移动。在含气量50%和含气量0%的条件下,DIB00V和NX70s没有显著变化(Bonferroni校正后DIB00VP = 0.019, NX70s; Bonferroni校正后P = 0.148)。DIB00V的后验率为100%,显著高于xy -1 (P = 0.046)。结论:与XY-1和nx70相比,DIB00V对来自视网膜表面的推力具有更大的IOL位移力,并且在空气或气体填塞的晶状体切除术中具有良好的z轴稳定性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
4.10
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信