Tight monitoring with colonoscopy and magnetic resonance enterography improves outcomes in patients with Crohn's disease.

IF 1.7 4区 医学 Q3 GASTROENTEROLOGY & HEPATOLOGY
Soyun Lim, Kwang Woo Kim, Jin Soo Moon, Se Hyung Kim, Seungbum Ryoo, Kyu Joo Park, Hyun Jung Lee, Jong Pil Im, Byeong Gwan Kim, Joo Sung Kim, Seong-Joon Koh
{"title":"Tight monitoring with colonoscopy and magnetic resonance enterography improves outcomes in patients with Crohn's disease.","authors":"Soyun Lim, Kwang Woo Kim, Jin Soo Moon, Se Hyung Kim, Seungbum Ryoo, Kyu Joo Park, Hyun Jung Lee, Jong Pil Im, Byeong Gwan Kim, Joo Sung Kim, Seong-Joon Koh","doi":"10.1080/00365521.2025.2544307","DOIUrl":null,"url":null,"abstract":"<p><strong>Background and aims: </strong>This study evaluated the impact of monitoring with colonoscopy and magnetic resonance enterography on clinical decision-making and long-term outcomes in advanced therapy-naïve Crohn's disease patients with moderate-to-severe disease.</p><p><strong>Methods: </strong>A retrospective review was conducted on 157 biologic-naïve Crohn's disease patients with moderate-to-severe disease at the initiation of advanced therapy between 2006 and 2023. Participants were categorized into three groups according to monitoring method within two years post-treatment: (1) tight monitoring (colonoscopy and magnetic resonance enterography), (2) semi-tight monitoring (either colonoscopy or magnetic resonance enterography), and (3) conventional monitoring (clinical outcomes including laboratory tests only). Treatment adjustments and long-term outcomes were compared.</p><p><strong>Results: </strong>Of 157 patients (69.4% male, median age 31 years), tight monitoring was associated with increased immunomodulator use (27.2% vs. 3.8%; <i>p</i> < 0.001) and reduced hospitalizations compared to conventional monitoring (5.4% vs. 38.8%; <i>p</i> < 0.001). The incidence of strictures was 0% in the tight monitoring group, compared to 21.3% in the conventional monitoring group, respectively (<i>p</i> = 0.011).</p><p><strong>Conclusion: </strong>Tight monitoring with both colonoscopy and magnetic resonance enterography within 2 years after advanced therapy initiation in patients with moderate-to-severe Crohn's disease is associated with timely treatment adjustments and improved long-term outcomes, particularly through better detection of residual inflammation.</p>","PeriodicalId":21461,"journal":{"name":"Scandinavian Journal of Gastroenterology","volume":" ","pages":"999-1010"},"PeriodicalIF":1.7000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scandinavian Journal of Gastroenterology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1080/00365521.2025.2544307","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/22 0:00:00","PubModel":"Epub","JCR":"Q3","JCRName":"GASTROENTEROLOGY & HEPATOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background and aims: This study evaluated the impact of monitoring with colonoscopy and magnetic resonance enterography on clinical decision-making and long-term outcomes in advanced therapy-naïve Crohn's disease patients with moderate-to-severe disease.

Methods: A retrospective review was conducted on 157 biologic-naïve Crohn's disease patients with moderate-to-severe disease at the initiation of advanced therapy between 2006 and 2023. Participants were categorized into three groups according to monitoring method within two years post-treatment: (1) tight monitoring (colonoscopy and magnetic resonance enterography), (2) semi-tight monitoring (either colonoscopy or magnetic resonance enterography), and (3) conventional monitoring (clinical outcomes including laboratory tests only). Treatment adjustments and long-term outcomes were compared.

Results: Of 157 patients (69.4% male, median age 31 years), tight monitoring was associated with increased immunomodulator use (27.2% vs. 3.8%; p < 0.001) and reduced hospitalizations compared to conventional monitoring (5.4% vs. 38.8%; p < 0.001). The incidence of strictures was 0% in the tight monitoring group, compared to 21.3% in the conventional monitoring group, respectively (p = 0.011).

Conclusion: Tight monitoring with both colonoscopy and magnetic resonance enterography within 2 years after advanced therapy initiation in patients with moderate-to-severe Crohn's disease is associated with timely treatment adjustments and improved long-term outcomes, particularly through better detection of residual inflammation.

结肠镜检查和磁共振肠造影密切监测可改善克罗恩病患者的预后。
背景和目的:本研究评估结肠镜和磁共振肠造影监测对中重度therapy-naïve克罗恩病患者临床决策和长期预后的影响。方法:回顾性分析2006年至2023年间157例biologic-naïve克罗恩病中重度患者在开始高级治疗时的资料。根据治疗后两年内的监测方法将参与者分为三组:(1)严密监测(结肠镜检查和磁共振肠造影),(2)半严密监测(结肠镜检查或磁共振肠造影)和(3)常规监测(仅包括实验室检查的临床结果)。比较治疗调整和长期结果。结果:157例患者中(69.4%为男性,中位年龄31岁),严密监测与免疫调节剂使用增加相关(27.2% vs. 3.8%; p p p = 0.011)。结论:中重度克罗恩病患者在开始高级治疗后2年内进行结肠镜检查和磁共振肠造影密切监测与及时调整治疗和改善长期预后相关,特别是通过更好地检测残余炎症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.40
自引率
5.30%
发文量
222
审稿时长
3-8 weeks
期刊介绍: The Scandinavian Journal of Gastroenterology is one of the most important journals for international medical research in gastroenterology and hepatology with international contributors, Editorial Board, and distribution
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信