Comparison of forces applied to oropharyngeal tissues with different blades during laryngoscopy in a standard pediatric endotracheal intubation model.

IF 1.5 4区 医学 Q2 MEDICINE, GENERAL & INTERNAL
Mohammed Sevimli, Aysun A Yilbas, Özge Özen, Başak Akca
{"title":"Comparison of forces applied to oropharyngeal tissues with different blades during laryngoscopy in a standard pediatric endotracheal intubation model.","authors":"Mohammed Sevimli, Aysun A Yilbas, Özge Özen, Başak Akca","doi":"10.15537/smj.2025.46.9.20250300","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>To measure the pressure exerted on the base of the tongue during endotracheal intubation using a standard pediatric model.</p><p><strong>Methods: </strong>The study was conducted in October-November 2022 at Hacettepe University Faculty of Medicine, Department of Anesthesiology and Reanimation, Ankara, Turkey. Anesthesiology residents performed intubations with Glidescope<sup>®</sup>-LoPro-T2, Storz<sup>®</sup>-C-MAC-paediatric-D-blade, and standard-Macintosh-1-blade on the same pediatric intubation model. The force exerted on the base of the tongue was measured during intubation using a force sensor. The duration and success of intubation, Cormack-Lehane-grade, and the force exerted on the oropharyngeal tissues were recorded.</p><p><strong>Results: </strong>A total of 156 intubations were performed by 52 residents. The force exerted with the Storz<sup>®</sup>-C-MAC-pediatric-D-blade was significantly lower when the Cormack-Lehane view was acquired and during the insertion of the endotracheal tube as compared to that exerted with the Glidescope<sup>®</sup>-LoPro-T2 and direct laryngoscopy with Macintosh-1-blade. Longer intubation time was associated with higher force application regardless of blade type.</p><p><strong>Conclusion: </strong>Videolaryngoscopy improved glottic view even in the same manikin as compared to direct laryngoscopy. Significantly lower forces were measured with the C-MAC-D-blade as compared to the other blades. Further studies on real patients are required to determine what amount of force exerted on the oropharyngeal tissue is clinically meaningful and thus avoid complications.</p>","PeriodicalId":21453,"journal":{"name":"Saudi Medical Journal","volume":"46 9","pages":"1008-1016"},"PeriodicalIF":1.5000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12441917/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Saudi Medical Journal","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.15537/smj.2025.46.9.20250300","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"MEDICINE, GENERAL & INTERNAL","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: To measure the pressure exerted on the base of the tongue during endotracheal intubation using a standard pediatric model.

Methods: The study was conducted in October-November 2022 at Hacettepe University Faculty of Medicine, Department of Anesthesiology and Reanimation, Ankara, Turkey. Anesthesiology residents performed intubations with Glidescope®-LoPro-T2, Storz®-C-MAC-paediatric-D-blade, and standard-Macintosh-1-blade on the same pediatric intubation model. The force exerted on the base of the tongue was measured during intubation using a force sensor. The duration and success of intubation, Cormack-Lehane-grade, and the force exerted on the oropharyngeal tissues were recorded.

Results: A total of 156 intubations were performed by 52 residents. The force exerted with the Storz®-C-MAC-pediatric-D-blade was significantly lower when the Cormack-Lehane view was acquired and during the insertion of the endotracheal tube as compared to that exerted with the Glidescope®-LoPro-T2 and direct laryngoscopy with Macintosh-1-blade. Longer intubation time was associated with higher force application regardless of blade type.

Conclusion: Videolaryngoscopy improved glottic view even in the same manikin as compared to direct laryngoscopy. Significantly lower forces were measured with the C-MAC-D-blade as compared to the other blades. Further studies on real patients are required to determine what amount of force exerted on the oropharyngeal tissue is clinically meaningful and thus avoid complications.

Abstract Image

Abstract Image

标准儿童气管插管模型喉镜检查时不同叶片作用于口咽组织的力比较。
目的:用标准的小儿模型测量气管插管时舌底施加的压力。方法:研究于2022年10 - 11月在土耳其安卡拉Hacettepe大学医学院麻醉与复苏系进行。麻醉科住院医师使用Glidescope®-LoPro-T2、Storz®- c- mac -儿科- d刀片和标准macintosh -1刀片在同一儿科插管模型上进行插管。在插管过程中使用力传感器测量施加在舌底的力。记录插管时间、插管成功率、cormack - lehane分级及施加在口咽组织上的力。结果:52名住院医师共插管156次。与Glidescope®-LoPro-T2和使用macintosh -1刀片的直接喉镜相比,Storz®- c- mac - pediatrics - d刀片在获得Cormack-Lehane视图和插入气管内管期间施加的力明显更低。无论刀片类型如何,插管时间越长,施加的力越大。结论:与直接喉镜相比,视频喉镜可以改善同一人体的声门视野。与其他叶片相比,c - mac - d叶片测得的力明显较低。需要对真实患者进行进一步的研究,以确定施加在口咽组织上的力的大小在临床上是有意义的,从而避免并发症。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Saudi Medical Journal
Saudi Medical Journal 医学-医学:内科
CiteScore
2.30
自引率
6.20%
发文量
203
审稿时长
12 months
期刊介绍: The Saudi Medical Journal is a monthly peer-reviewed medical journal. It is an open access journal, with content released under a Creative Commons attribution-noncommercial license. The journal publishes original research articles, review articles, Systematic Reviews, Case Reports, Brief Communication, Brief Report, Clinical Note, Clinical Image, Editorials, Book Reviews, Correspondence, and Student Corner.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信