Comparison of tolerance to induced astigmatism in pseudophakic eyes implanted with dual-technology diffractive IOL and enhanced monofocal IOL.

IF 1.8 4区 医学 Q2 OPHTHALMOLOGY
Indian Journal of Ophthalmology Pub Date : 2025-09-01 Epub Date: 2025-08-29 DOI:10.4103/IJO.IJO_2224_24
Paulo Tadeu Silva Campos, Wilson Takashi Hida, Bernardo Kaplan Moscovici, Larissa Gouvea, Maurício Agne Newald, Jonathan Clive Lake, Cesar Martins Cortez Vilar, André Lins De Medeiros, Patrick Frensel De Moraes Tzelikis, Antonio Francisco Pimenta Motta, Marcelo Novoa Colombo-Barboza, Pedro Carlos Carricondo
{"title":"Comparison of tolerance to induced astigmatism in pseudophakic eyes implanted with dual-technology diffractive IOL and enhanced monofocal IOL.","authors":"Paulo Tadeu Silva Campos, Wilson Takashi Hida, Bernardo Kaplan Moscovici, Larissa Gouvea, Maurício Agne Newald, Jonathan Clive Lake, Cesar Martins Cortez Vilar, André Lins De Medeiros, Patrick Frensel De Moraes Tzelikis, Antonio Francisco Pimenta Motta, Marcelo Novoa Colombo-Barboza, Pedro Carlos Carricondo","doi":"10.4103/IJO.IJO_2224_24","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare the effect of induced astigmatism and defocus on visual performance in patients with a dominant eye implanted with a dual-technology diffractive intraocular lens (IOL) or an enhanced monofocal IOL.</p><p><strong>Methods: </strong>This non-randomized cohort study included 35 patients in each group. Group 1 underwent phacoemulsification and received the Tecnis Synergy IOL in the dominant eye. Group 2 received the Tecnis Eyhance IOL. All surgeries were performed using a 2.2 mm clear corneal incision. Patients were evaluated 16 weeks postoperatively. Astigmatic tolerance was assessed by measuring monocular distance visual acuity (DVA) using negative cylindrical (CYL) lenses of varying powers and axes on a defocus curve.</p><p><strong>Results: </strong>There were no significant differences in overall induced astigmatism between groups. However, Group 1 showed significantly better DVA with against-the-rule (ATR) astigmatism (90°) than with-the-rule (WTR, 180°) using 1.50 D CYL (P < 0.05). Additionally, Group 1 outperformed Group 2 at 1.00 D and 1.50 D ATR under -1.00 D defocus (P < 0.05). These findings were both statistically and clinically relevant, indicating that residual ATR astigmatism may be better tolerated by patients with a dual-technology diffractive IOL, resulting in improved performance for near and intermediate tasks.</p><p><strong>Conclusion: </strong>The Tecnis Synergy IOL demonstrated superior tolerance to ATR astigmatism compared to the Tecnis Eyhance IOL, especially at higher cylindrical powers under -1.00 D defocus. These results highlight the relevance of astigmatic tolerance in IOL selection for spectacle independence, particularly in patients with ATR astigmatism. Findings are specific to these IOLs and should not be generalized to other premium lenses.</p>","PeriodicalId":13329,"journal":{"name":"Indian Journal of Ophthalmology","volume":"73 9","pages":"1302-1306"},"PeriodicalIF":1.8000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12448531/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Indian Journal of Ophthalmology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4103/IJO.IJO_2224_24","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/29 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare the effect of induced astigmatism and defocus on visual performance in patients with a dominant eye implanted with a dual-technology diffractive intraocular lens (IOL) or an enhanced monofocal IOL.

Methods: This non-randomized cohort study included 35 patients in each group. Group 1 underwent phacoemulsification and received the Tecnis Synergy IOL in the dominant eye. Group 2 received the Tecnis Eyhance IOL. All surgeries were performed using a 2.2 mm clear corneal incision. Patients were evaluated 16 weeks postoperatively. Astigmatic tolerance was assessed by measuring monocular distance visual acuity (DVA) using negative cylindrical (CYL) lenses of varying powers and axes on a defocus curve.

Results: There were no significant differences in overall induced astigmatism between groups. However, Group 1 showed significantly better DVA with against-the-rule (ATR) astigmatism (90°) than with-the-rule (WTR, 180°) using 1.50 D CYL (P < 0.05). Additionally, Group 1 outperformed Group 2 at 1.00 D and 1.50 D ATR under -1.00 D defocus (P < 0.05). These findings were both statistically and clinically relevant, indicating that residual ATR astigmatism may be better tolerated by patients with a dual-technology diffractive IOL, resulting in improved performance for near and intermediate tasks.

Conclusion: The Tecnis Synergy IOL demonstrated superior tolerance to ATR astigmatism compared to the Tecnis Eyhance IOL, especially at higher cylindrical powers under -1.00 D defocus. These results highlight the relevance of astigmatic tolerance in IOL selection for spectacle independence, particularly in patients with ATR astigmatism. Findings are specific to these IOLs and should not be generalized to other premium lenses.

Abstract Image

Abstract Image

双技术衍射人工晶状体与增强单焦点人工晶状体对人工晶状体诱导散光的耐受性比较。
目的:比较优势眼植入双技术衍射人工晶状体(IOL)和增强单焦点人工晶状体(IOL)患者诱导散光和离焦对视力的影响。方法:采用非随机队列研究,每组35例。组1行超声乳化术,优势眼植入Tecnis Synergy人工晶状体。第二组采用Tecnis Eyhance人工晶状体。所有手术均采用2.2 mm透明角膜切口。术后16周对患者进行评估。通过在离焦曲线上使用不同倍率和轴向的负圆柱形(CYL)透镜测量单眼距离视力(DVA)来评估散光容差。结果:两组患者总体诱导散光无显著性差异。而第1组在1.50 D CYL下,反规则(ATR)散光(90°)的DVA明显优于顺规则(WTR, 180°)(P < 0.05)。在-1.00 D离焦情况下,组1在1.00 D和1.50 D ATR优于组2 (P < 0.05)。这些发现具有统计学和临床相关性,表明双技术衍射IOL患者可以更好地耐受残余ATR散光,从而提高近距离和中期任务的表现。结论:与Tecnis enhanced IOL相比,Tecnis Synergy IOL对ATR散光的耐受性更好,特别是在-1.00 D离焦下的高圆柱形屈光度下。这些结果强调了散光耐受性与人工晶状体选择的相关性,特别是在ATR散光患者中。这些发现是特定于这些人工晶体的,不应推广到其他优质晶体。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.80
自引率
19.40%
发文量
1963
审稿时长
38 weeks
期刊介绍: Indian Journal of Ophthalmology covers clinical, experimental, basic science research and translational research studies related to medical, ethical and social issues in field of ophthalmology and vision science. Articles with clinical interest and implications will be given preference.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信