Oculometric Assessment of Sensorimotor Impairment Associated with Liver Disease Is as Sensitive as Standard of Care Cognitive Tests.

IF 2.1 Q3 GERIATRICS & GERONTOLOGY
Dorion Liston, Katherine Wong, Aaron Yeoh, Shalonda Haywood, Aparna Goel, Paul Kwo, Quinn Kennedy, Philip N Okafor
{"title":"Oculometric Assessment of Sensorimotor Impairment Associated with Liver Disease Is as Sensitive as Standard of Care Cognitive Tests.","authors":"Dorion Liston, Katherine Wong, Aaron Yeoh, Shalonda Haywood, Aparna Goel, Paul Kwo, Quinn Kennedy, Philip N Okafor","doi":"10.3390/geriatrics10040112","DOIUrl":null,"url":null,"abstract":"<p><strong>Significance: </strong>Hepatic encephalopathy (HE) occurs in 20-80% of patients with liver cirrhosis, impacting attention, memory, processing speed, and visuospatial skills. HE standard-of-care psychometric assessments are time-consuming and require staff training. Oculometrics may provide a fast, non-invasive brain health assessment that can be self-administered in a medical environment.</p><p><strong>Purpose: </strong>We investigated whether an oculometric assessment could measure the severity of HE as accurately as standard-of-care psychometric methods.</p><p><strong>Methods: </strong>Forty-eight participants (19 with decompensated cirrhosis, 10 with compensated cirrhosis, 19 controls) completed a previously validated five-minute oculometric test and the standard-of-care psychometric hepatic encephalopathy (PHE) battery. The oculometric test consists of following a dot as it moves across a computer screen and generates 10 metrics including a summary score called nFit. The PHE battery entails five standard cognitive tests, generating seven metrics including a PHE composite score (PHES).</p><p><strong>Results: </strong>The oculometric summary score, nFit, correlated with the current diagnostic standard, the PHES (<i>r</i> = 0.51, <i>p</i> < 0.001), the presence or absence of HE as determined by PHES composite (<i>r</i> = -0.44, <i>p</i> < 0.001), as well as the severity of cirrhosis (<i>r</i> = -0.59, <i>p</i> < 0.001). Additionally, performance on both nFit and PHES distinguished compensated (ROC: nFit: 0.71, PHES: 0.68) and decompensated (ROC: nFit: 0.88, PHES: 0.85) patient groups from control participants comparably. Finally, compared to participants with decompensated cirrhosis, control participants had better scores for almost all oculometrics: acceleration, catch-up saccade amplitude, proportion smooth, direction noise, and speed noise.</p><p><strong>Conclusions: </strong>Patients with liver disease showed impairment on multiple aspects of visual processing compared to a control group. These functional visual processing impairments correlate with the presence or absence of HE, showing significant sensitivity in distinguishing people with HE from controls. Oculometric tests provide a quick, non-invasive functional assessment of brain health in patients with liver disease, with sensitivity indistinguishable from standard-of-case psychometric tests.</p>","PeriodicalId":12653,"journal":{"name":"Geriatrics","volume":"10 4","pages":""},"PeriodicalIF":2.1000,"publicationDate":"2025-08-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12385179/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Geriatrics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.3390/geriatrics10040112","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"GERIATRICS & GERONTOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Significance: Hepatic encephalopathy (HE) occurs in 20-80% of patients with liver cirrhosis, impacting attention, memory, processing speed, and visuospatial skills. HE standard-of-care psychometric assessments are time-consuming and require staff training. Oculometrics may provide a fast, non-invasive brain health assessment that can be self-administered in a medical environment.

Purpose: We investigated whether an oculometric assessment could measure the severity of HE as accurately as standard-of-care psychometric methods.

Methods: Forty-eight participants (19 with decompensated cirrhosis, 10 with compensated cirrhosis, 19 controls) completed a previously validated five-minute oculometric test and the standard-of-care psychometric hepatic encephalopathy (PHE) battery. The oculometric test consists of following a dot as it moves across a computer screen and generates 10 metrics including a summary score called nFit. The PHE battery entails five standard cognitive tests, generating seven metrics including a PHE composite score (PHES).

Results: The oculometric summary score, nFit, correlated with the current diagnostic standard, the PHES (r = 0.51, p < 0.001), the presence or absence of HE as determined by PHES composite (r = -0.44, p < 0.001), as well as the severity of cirrhosis (r = -0.59, p < 0.001). Additionally, performance on both nFit and PHES distinguished compensated (ROC: nFit: 0.71, PHES: 0.68) and decompensated (ROC: nFit: 0.88, PHES: 0.85) patient groups from control participants comparably. Finally, compared to participants with decompensated cirrhosis, control participants had better scores for almost all oculometrics: acceleration, catch-up saccade amplitude, proportion smooth, direction noise, and speed noise.

Conclusions: Patients with liver disease showed impairment on multiple aspects of visual processing compared to a control group. These functional visual processing impairments correlate with the presence or absence of HE, showing significant sensitivity in distinguishing people with HE from controls. Oculometric tests provide a quick, non-invasive functional assessment of brain health in patients with liver disease, with sensitivity indistinguishable from standard-of-case psychometric tests.

Abstract Image

Abstract Image

Abstract Image

视力评估与肝脏疾病相关的感觉运动障碍与标准护理认知测试一样敏感。
意义:肝性脑病(HE)发生在20-80%的肝硬化患者中,影响注意力、记忆、处理速度和视觉空间技能。HE标准护理心理测量评估耗时且需要对工作人员进行培训。视光可以提供一种快速、无创的大脑健康评估,可以在医疗环境中自我管理。目的:我们研究眼测法是否能像标准护理心理测量法一样准确地测量HE的严重程度。方法:48名参与者(19名失代偿性肝硬化患者,10名代偿性肝硬化患者,19名对照组)完成了先前验证的5分钟视力测试和标准护理心理测量肝性脑病(PHE)电池。视力测试包括跟随一个在电脑屏幕上移动的点,并生成10个指标,其中包括一个名为nFit的综合得分。PHE电池需要五个标准认知测试,产生七个指标,包括PHE综合评分(PHE)。结果:眼科综合评分nFit与当前诊断标准、PHES (r = 0.51, p < 0.001)、PHES综合评分是否存在HE (r = -0.44, p < 0.001)以及肝硬化严重程度(r = -0.59, p < 0.001)相关。此外,nFit和PHES的表现将代偿(ROC: nFit: 0.71, PHES: 0.68)和失代偿(ROC: nFit: 0.88, PHES: 0.85)患者组与对照组相比具有可比性。最后,与失代偿性肝硬化受试者相比,对照组受试者在几乎所有的视力测量指标上都有更好的得分:加速度、追赶扫视幅度、比例平滑、方向噪声和速度噪声。结论:与对照组相比,肝病患者在视觉处理的多个方面表现出损害。这些功能性视觉处理障碍与HE的存在与否相关,在区分HE患者和对照组方面表现出显著的敏感性。视力测试为肝病患者的大脑健康提供了一种快速、无创的功能评估,其灵敏度与标准病例心理测试无异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Geriatrics
Geriatrics 医学-老年医学
CiteScore
3.30
自引率
0.00%
发文量
115
审稿时长
20.03 days
期刊介绍: • Geriatric biology • Geriatric health services research • Geriatric medicine research • Geriatric neurology, stroke, cognition and oncology • Geriatric surgery • Geriatric physical functioning, physical health and activity • Geriatric psychiatry and psychology • Geriatric nutrition • Geriatric epidemiology • Geriatric rehabilitation
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信