A prospective study of transorbital ultrasound multimodal imaging in the detection and evaluation of increased intracranial pressure.

IF 3.2 3区 医学 Q2 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Peng He, Lanlan Yu, Xingheng Wang, Bo Ren, Peng Gu, Fei Yang, Yuan Zou
{"title":"A prospective study of transorbital ultrasound multimodal imaging in the detection and evaluation of increased intracranial pressure.","authors":"Peng He, Lanlan Yu, Xingheng Wang, Bo Ren, Peng Gu, Fei Yang, Yuan Zou","doi":"10.1186/s12880-025-01893-w","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>To develop and validate a multimodal transorbital ultrasound model for noninvasive detection of increased intracranial pressure (IICP) by integrating anatomical and hemodynamic parameters.</p><p><strong>Methods: </strong>In this prospective diagnostic study, 136 neurology patients scheduled for lumbar puncture underwent pre-procedural ultrasound measurement of optic nerve sheath diameter (ONSD), ONSD-to-eyeball transverse diameter ratio (ONSD/ETD), and central retinal artery hemodynamics (peak systolic velocity [PSV], resistance index [RI]). Patients were classified as IICP (CSF pressure > 200 mmH₂O) or normal ICP (NICP) groups. Parameter performance was analyzed via ROC curves; multivariate logistic regression constructed a predictive model.</p><p><strong>Results: </strong>The IICP group (n = 52) showed significantly higher ONSD (5.06 ± 0.49 vs. 4.19 ± 0.82 mm), ONSD/ETD (0.24 ± 0.02 vs.0.19 ± 0.04), and RI (0.66 ± 0.07vs.0.56 ± 0.09) but lower PSV (9.45 ± 1.38 vs.10.86 ± 2.14 cm/s) versus NICP (n = 84) (all P < 0.001). The integrated model (ONSD + ONSD/ETD + PSV + RI) achieved superior diagnostic accuracy: AUC 0.95 (95% CI: 0.922-0.988), sensitivity 88.1%, specificity 98.0%, Youden's index 0.86-significantly outperforming any single parameter (AUC 0.67-0.87, P < 0.001)-with the predictive equation: Logit(P) = 1.94×ONSD-84.6×ONSD/ETD + 0.79×PSV-3.8×RI + 11.05.</p><p><strong>Conclusion: </strong>Transorbital multimodal ultrasound combining structural and vascular parameters enables highly accurate, rapid IICP screening, offering a clinically viable noninvasive alternative to conventional monitoring.</p>","PeriodicalId":9020,"journal":{"name":"BMC Medical Imaging","volume":"25 1","pages":"349"},"PeriodicalIF":3.2000,"publicationDate":"2025-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12379483/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Medical Imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12880-025-01893-w","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Background: To develop and validate a multimodal transorbital ultrasound model for noninvasive detection of increased intracranial pressure (IICP) by integrating anatomical and hemodynamic parameters.

Methods: In this prospective diagnostic study, 136 neurology patients scheduled for lumbar puncture underwent pre-procedural ultrasound measurement of optic nerve sheath diameter (ONSD), ONSD-to-eyeball transverse diameter ratio (ONSD/ETD), and central retinal artery hemodynamics (peak systolic velocity [PSV], resistance index [RI]). Patients were classified as IICP (CSF pressure > 200 mmH₂O) or normal ICP (NICP) groups. Parameter performance was analyzed via ROC curves; multivariate logistic regression constructed a predictive model.

Results: The IICP group (n = 52) showed significantly higher ONSD (5.06 ± 0.49 vs. 4.19 ± 0.82 mm), ONSD/ETD (0.24 ± 0.02 vs.0.19 ± 0.04), and RI (0.66 ± 0.07vs.0.56 ± 0.09) but lower PSV (9.45 ± 1.38 vs.10.86 ± 2.14 cm/s) versus NICP (n = 84) (all P < 0.001). The integrated model (ONSD + ONSD/ETD + PSV + RI) achieved superior diagnostic accuracy: AUC 0.95 (95% CI: 0.922-0.988), sensitivity 88.1%, specificity 98.0%, Youden's index 0.86-significantly outperforming any single parameter (AUC 0.67-0.87, P < 0.001)-with the predictive equation: Logit(P) = 1.94×ONSD-84.6×ONSD/ETD + 0.79×PSV-3.8×RI + 11.05.

Conclusion: Transorbital multimodal ultrasound combining structural and vascular parameters enables highly accurate, rapid IICP screening, offering a clinically viable noninvasive alternative to conventional monitoring.

Abstract Image

Abstract Image

Abstract Image

经眶超声多模态成像检测和评价颅内压增高的前瞻性研究。
背景:通过整合解剖学和血流动力学参数,建立并验证一种多模态经眶超声模型,用于无创检测颅内压升高(IICP)。方法:在这项前瞻性诊断研究中,136例神经内科患者计划行腰椎穿刺,术前超声测量视神经鞘直径(ONSD)、视神经鞘与眼球横径比(ONSD/ETD)和视网膜中央动脉血流动力学(峰值收缩速度[PSV]、阻力指数[RI])。将患者分为IICP (CSF pressure > ~ 200mmh₂O)组和正常ICP (NICP)组。通过ROC曲线分析参数性能;多元逻辑回归构建了预测模型。结果:IICP组(n = 52)的ONSD(5.06±0.49 vs. 4.19±0.82 mm)、ONSD/ETD(0.24±0.02 vs.0.19±0.04)和RI(0.66±0.07vs.0.56±0.09)显著高于NICP组(n = 84), PSV(9.45±1.38 vs.10.86±2.14 cm/s)显著低于NICP组(均为P)。结论:经眶多模态超声结合结构和血管参数可实现高度准确、快速的IICP筛查,为常规监测提供了临床可行的无创替代方案。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Medical Imaging
BMC Medical Imaging RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING-
CiteScore
4.60
自引率
3.70%
发文量
198
审稿时长
27 weeks
期刊介绍: BMC Medical Imaging is an open access journal publishing original peer-reviewed research articles in the development, evaluation, and use of imaging techniques and image processing tools to diagnose and manage disease.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信