Tommaso Fabris MD, Michele Strosio MD, Francesco Putortì MD, Consolato Mesiani MD, Antonio Amadio MD, Simone Tripi MD, Andrea Panza MD, Giuseppe Tarantini MD, PhD
{"title":"Guiding Early Management in Severe Mitral Stenosis with Extensive Mitral Annular Calcification: A Transseptal ViMAC Case","authors":"Tommaso Fabris MD, Michele Strosio MD, Francesco Putortì MD, Consolato Mesiani MD, Antonio Amadio MD, Simone Tripi MD, Andrea Panza MD, Giuseppe Tarantini MD, PhD","doi":"10.1016/j.amjcard.2025.08.033","DOIUrl":null,"url":null,"abstract":"<div><div>Mitral annular calcification (MAC) related mitral stenosis (MS) presents a significant therapeutic challenge, especially in patients considered high-risk or inoperable. Transcatheter mitral valve replacement (TMVR) has emerged as an alternative, but the procedure remains technically demanding due to anatomical complexities and the risk of complications. We report the case of a 72-year-old man with severe MAC and MS, who successfully underwent TMVR using a 29 mm Edwards Sapien 3 valve. A key innovation in this case was the implementation of a novel balloon-assisted trackability assessment to optimize the trajectory of the delivery system. Prior to septostomy, a noncompliant balloon was positioned and inflated at the mitral level, enabling real-time evaluation of coaxial alignment and confirming the feasibility of advancing the prosthesis along the intended path. Once optimal trajectory was verified, the same balloon was used to perform the septostomy, ensuring accurate and controlled passage of the delivery system, and ultimately facilitating precise implantation. At 3-year follow-up, the patient remained asymptomatic with a well-functioning valve and stable hemodynamics. This case highlights the value of preseptostomy balloon-based trackability assessment as a simple yet highly effective technique to enhance procedural precision in TMVR for MAC.</div></div>","PeriodicalId":7705,"journal":{"name":"American Journal of Cardiology","volume":"258 ","pages":"Pages 21-23"},"PeriodicalIF":2.1000,"publicationDate":"2025-08-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"American Journal of Cardiology","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0002914925004953","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Mitral annular calcification (MAC) related mitral stenosis (MS) presents a significant therapeutic challenge, especially in patients considered high-risk or inoperable. Transcatheter mitral valve replacement (TMVR) has emerged as an alternative, but the procedure remains technically demanding due to anatomical complexities and the risk of complications. We report the case of a 72-year-old man with severe MAC and MS, who successfully underwent TMVR using a 29 mm Edwards Sapien 3 valve. A key innovation in this case was the implementation of a novel balloon-assisted trackability assessment to optimize the trajectory of the delivery system. Prior to septostomy, a noncompliant balloon was positioned and inflated at the mitral level, enabling real-time evaluation of coaxial alignment and confirming the feasibility of advancing the prosthesis along the intended path. Once optimal trajectory was verified, the same balloon was used to perform the septostomy, ensuring accurate and controlled passage of the delivery system, and ultimately facilitating precise implantation. At 3-year follow-up, the patient remained asymptomatic with a well-functioning valve and stable hemodynamics. This case highlights the value of preseptostomy balloon-based trackability assessment as a simple yet highly effective technique to enhance procedural precision in TMVR for MAC.
期刊介绍:
Published 24 times a year, The American Journal of Cardiology® is an independent journal designed for cardiovascular disease specialists and internists with a subspecialty in cardiology throughout the world. AJC is an independent, scientific, peer-reviewed journal of original articles that focus on the practical, clinical approach to the diagnosis and treatment of cardiovascular disease. AJC has one of the fastest acceptance to publication times in Cardiology. Features report on systemic hypertension, methodology, drugs, pacing, arrhythmia, preventive cardiology, congestive heart failure, valvular heart disease, congenital heart disease, and cardiomyopathy. Also included are editorials, readers'' comments, and symposia.