Transcatheter correction of superior sinus venosus defects: Early and mid-term results in a prospective, nationwide, multi-center study

IF 2.2 3区 医学 Q2 CARDIAC & CARDIOVASCULAR SYSTEMS
Grégoire Albenque , clement Batteux , Clement Karsenty , Bouzguenda Ivan , Philippe Aldebert , Jelena Radojevic , Gilles Bosser , Fanny Dion , Bruno Lefort , Pamela Moceri , François Godart , Raymond Haddad , Fabien Labombarda , Charlotte Denis , Elise Barre , Hélène Bouvaist , Nicolas Combes , Ali Houeijeh , Vlad Ciobotaru , Sebastien Hascoet
{"title":"Transcatheter correction of superior sinus venosus defects: Early and mid-term results in a prospective, nationwide, multi-center study","authors":"Grégoire Albenque ,&nbsp;clement Batteux ,&nbsp;Clement Karsenty ,&nbsp;Bouzguenda Ivan ,&nbsp;Philippe Aldebert ,&nbsp;Jelena Radojevic ,&nbsp;Gilles Bosser ,&nbsp;Fanny Dion ,&nbsp;Bruno Lefort ,&nbsp;Pamela Moceri ,&nbsp;François Godart ,&nbsp;Raymond Haddad ,&nbsp;Fabien Labombarda ,&nbsp;Charlotte Denis ,&nbsp;Elise Barre ,&nbsp;Hélène Bouvaist ,&nbsp;Nicolas Combes ,&nbsp;Ali Houeijeh ,&nbsp;Vlad Ciobotaru ,&nbsp;Sebastien Hascoet","doi":"10.1016/j.acvd.2025.06.047","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Transcatheter correction has been a new innovative treatment for superior sinus venosus defects (SVDs). A dedicated long partially covered XXL stent has been developed specifically for this procedure. Its safety and efficacy have to be investigated.</div></div><div><h3>Method</h3><div>This study aims to evaluate the efficacy and safety of transcatheter SVDs correction with the OTIMUS XXL® partially covered stent.</div></div><div><h3>Results</h3><div>Thirty adults were enrolled over one year in 5 centers (mean age 61 years; female, 73%; dyspnea, 90%; history of atrial arrhythmia, 43%; pulmonary hypertension, 40%; heart failure, 47%; mean indexed right ventricular end-telediastolic volume<!--> <!-->=<!--> <!-->140<!--> <!-->mL/m<sup>2</sup> on MRI). Simulation of transcatheter SVD closure was done virtually and on 3D printed models in all cases. All procedures were successful. Pulmonary vein pathway was protected in 57% of cases. Stents of 100<!--> <!-->mm and 80<!--> <!-->mm were implanted in 67% and 33% of cases respectively, using Gemini balloons. Additional stents were implanted at the upper part in 3 patients (10%). An ostium secundum atrial septal defect was closed during the same procedure in 2 patients (6.7%). No stent embolization, pulmonary vein compression, significant residual shunt or tamponade were observed. No peri-procedural death was reported during the follow-up. In one patient, a moderate pericardial effusion was observed 7 days after the procedure and resolved spontaneously. A flat thrombus of 4<!--> <!-->×<!--> <!-->22<!--> <!-->mm was fortuitously observed upholstering the bottom part of the covered stent on the systematic computed tomography scan control at 6 months. No other stent related adverse event.</div></div><div><h3>Conclusion</h3><div>Transcatheter SVDs correction using OPTIMUS XXL® covered stents is safe and effective with excellent early and mid-term outcomes.</div></div>","PeriodicalId":55472,"journal":{"name":"Archives of Cardiovascular Diseases","volume":"118 8","pages":"Page S272"},"PeriodicalIF":2.2000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Archives of Cardiovascular Diseases","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S1875213625003742","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction

Transcatheter correction has been a new innovative treatment for superior sinus venosus defects (SVDs). A dedicated long partially covered XXL stent has been developed specifically for this procedure. Its safety and efficacy have to be investigated.

Method

This study aims to evaluate the efficacy and safety of transcatheter SVDs correction with the OTIMUS XXL® partially covered stent.

Results

Thirty adults were enrolled over one year in 5 centers (mean age 61 years; female, 73%; dyspnea, 90%; history of atrial arrhythmia, 43%; pulmonary hypertension, 40%; heart failure, 47%; mean indexed right ventricular end-telediastolic volume = 140 mL/m2 on MRI). Simulation of transcatheter SVD closure was done virtually and on 3D printed models in all cases. All procedures were successful. Pulmonary vein pathway was protected in 57% of cases. Stents of 100 mm and 80 mm were implanted in 67% and 33% of cases respectively, using Gemini balloons. Additional stents were implanted at the upper part in 3 patients (10%). An ostium secundum atrial septal defect was closed during the same procedure in 2 patients (6.7%). No stent embolization, pulmonary vein compression, significant residual shunt or tamponade were observed. No peri-procedural death was reported during the follow-up. In one patient, a moderate pericardial effusion was observed 7 days after the procedure and resolved spontaneously. A flat thrombus of 4 × 22 mm was fortuitously observed upholstering the bottom part of the covered stent on the systematic computed tomography scan control at 6 months. No other stent related adverse event.

Conclusion

Transcatheter SVDs correction using OPTIMUS XXL® covered stents is safe and effective with excellent early and mid-term outcomes.
经导管矫正上静脉窦缺损:一项前瞻性、全国性、多中心研究的早期和中期结果
导管矫正是治疗上静脉窦缺损(SVDs)的一种新颖的治疗方法。专门为该手术开发了一种专用的长部分覆盖的XXL支架。它的安全性和有效性还有待研究。方法本研究旨在评价OTIMUS XXL®部分覆盖支架在经导管svd矫正中的有效性和安全性。结果30名成人在1年内入组5个中心(平均年龄61岁,女性73%,呼吸困难90%,房性心律失常43%,肺动脉高压40%,心力衰竭47%,右心室舒张末期平均指数值= 140 mL/m2)。在所有病例中,通过虚拟和3D打印模型模拟经导管SVD闭合。所有手术均成功。57%的病例肺静脉通路得到保护。使用Gemini球囊植入100 mm和80 mm支架的比例分别为67%和33%。3例(10%)患者在上半部分植入了额外的支架。2例(6.7%)患者在同一手术过程中关闭了第二口房间隔缺损。未见支架栓塞、肺静脉受压、明显残余分流或填塞。随访期间无手术期间死亡报告。一名患者术后7天出现中度心包积液,并自行消退。6个月时,在系统ct扫描控制中,偶然发现覆盖支架底部有一个4 × 22 mm的扁平血栓。无其他支架相关不良事件。结论OPTIMUS XXL®覆盖支架经导管svd矫正是安全有效的,具有良好的早期和中期预后。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Archives of Cardiovascular Diseases
Archives of Cardiovascular Diseases 医学-心血管系统
CiteScore
4.40
自引率
6.70%
发文量
87
审稿时长
34 days
期刊介绍: The Journal publishes original peer-reviewed clinical and research articles, epidemiological studies, new methodological clinical approaches, review articles and editorials. Topics covered include coronary artery and valve diseases, interventional and pediatric cardiology, cardiovascular surgery, cardiomyopathy and heart failure, arrhythmias and stimulation, cardiovascular imaging, vascular medicine and hypertension, epidemiology and risk factors, and large multicenter studies. Archives of Cardiovascular Diseases also publishes abstracts of papers presented at the annual sessions of the Journées Européennes de la Société Française de Cardiologie and the guidelines edited by the French Society of Cardiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信