Sait Sendag, Henrik Wagner, Ali Osman Turgut, Davut Koca, Gerhard Schuler, Axel Wehrend
{"title":"The Elecsys AMH Assay Is a Suitable Method to Detect Gonadal Tissue in Male Alpacas and Llamas.","authors":"Sait Sendag, Henrik Wagner, Ali Osman Turgut, Davut Koca, Gerhard Schuler, Axel Wehrend","doi":"10.1002/vms3.70558","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Anti-Müllerian hormone (AMH) has become an important hormonal parameter for the detection of gonadal tissue and for the diagnosis of gonadal functions and pathologies. To our knowledge, there is currently no homologous test for AMH measurements in South American camelids (SACs). Therefore, the objective of the present study was to determine serum AMH concentrations in postpubertal male alpacas and, for the first time, in llamas, using the Elecsys AMH assay kit that has not previously been tested in these species. To obtain indications of the specificity of this method in SAC, measurements were carried out in male gelding in which concentrations below the detection limit were to be expected.</p><p><strong>Methods: </strong>In this context, 37 blood samples collected by jugular venipuncture from 21 alpacas and 16 llamas were used. The obtained blood was centrifuged at 3000 g for 20 min, and the serum was stored in Eppendorf tubes at -20°C until AMH concentrations were measurement. The measurement of AMH levels was conducted in a commercial diagnostic laboratory (Laboklin, Bad Kissingen, Germany) using the electrochemiluminescence immunoassay kit Elecsys AMH run on the fully automated Cobas e 601 analyser (Roche Diagnostics Deutschland GmbH, Mannheim). The AMH test had a minimum detection limit of 0.01 ng/mL and a maximum detection limit of 23 ng/mL. The intra-assay coefficient of variation is between 2.7% and 3.3%.</p><p><strong>Results: </strong>Blood serum AMH levels ranged between 4.10 and 22 ng/mL (median: 9.80 ng/mL) and 1.79 and 10.05 ng/mL (median: 4.00) in intact alpacas (age: 6.30 ± 2.71 years; n = 10) and llamas (age: 5.50 ± 4.34; n = 8), respectively, and were significantly different between samples obtained from the two species (p < 0.05). Correlation analyses regarding an age dependence of AMH concentrations yielded negative correlation coefficients for both species but non-significant p values (alpaca: r = -0.165, p = 0.649; llama: r = -0.547, p = 0.160). In alpaca (n = 11) and llama geldings (n = 8), blood serum AMH levels were below 0.01 ng/mL (p < 0.001). These results prove that the antibodies used in the Elecsys AMH assay significantly and specifically cross-react with SAC AMH.</p><p><strong>Conclusions: </strong>In gelding llamas and alpacas, AMH concentrations were below the limit of detection (<0.01 ng/mL), which was significantly lower compared to intact animals (p < 0.001). The Elecsys AMH assay is therefore considered a suitable method for detecting gonadal tissue in SAC.</p>","PeriodicalId":23543,"journal":{"name":"Veterinary Medicine and Science","volume":"11 5","pages":"e70558"},"PeriodicalIF":1.7000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12359723/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Medicine and Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1002/vms3.70558","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: Anti-Müllerian hormone (AMH) has become an important hormonal parameter for the detection of gonadal tissue and for the diagnosis of gonadal functions and pathologies. To our knowledge, there is currently no homologous test for AMH measurements in South American camelids (SACs). Therefore, the objective of the present study was to determine serum AMH concentrations in postpubertal male alpacas and, for the first time, in llamas, using the Elecsys AMH assay kit that has not previously been tested in these species. To obtain indications of the specificity of this method in SAC, measurements were carried out in male gelding in which concentrations below the detection limit were to be expected.
Methods: In this context, 37 blood samples collected by jugular venipuncture from 21 alpacas and 16 llamas were used. The obtained blood was centrifuged at 3000 g for 20 min, and the serum was stored in Eppendorf tubes at -20°C until AMH concentrations were measurement. The measurement of AMH levels was conducted in a commercial diagnostic laboratory (Laboklin, Bad Kissingen, Germany) using the electrochemiluminescence immunoassay kit Elecsys AMH run on the fully automated Cobas e 601 analyser (Roche Diagnostics Deutschland GmbH, Mannheim). The AMH test had a minimum detection limit of 0.01 ng/mL and a maximum detection limit of 23 ng/mL. The intra-assay coefficient of variation is between 2.7% and 3.3%.
Results: Blood serum AMH levels ranged between 4.10 and 22 ng/mL (median: 9.80 ng/mL) and 1.79 and 10.05 ng/mL (median: 4.00) in intact alpacas (age: 6.30 ± 2.71 years; n = 10) and llamas (age: 5.50 ± 4.34; n = 8), respectively, and were significantly different between samples obtained from the two species (p < 0.05). Correlation analyses regarding an age dependence of AMH concentrations yielded negative correlation coefficients for both species but non-significant p values (alpaca: r = -0.165, p = 0.649; llama: r = -0.547, p = 0.160). In alpaca (n = 11) and llama geldings (n = 8), blood serum AMH levels were below 0.01 ng/mL (p < 0.001). These results prove that the antibodies used in the Elecsys AMH assay significantly and specifically cross-react with SAC AMH.
Conclusions: In gelding llamas and alpacas, AMH concentrations were below the limit of detection (<0.01 ng/mL), which was significantly lower compared to intact animals (p < 0.001). The Elecsys AMH assay is therefore considered a suitable method for detecting gonadal tissue in SAC.
期刊介绍:
Veterinary Medicine and Science is the peer-reviewed journal for rapid dissemination of research in all areas of veterinary medicine and science. The journal aims to serve the research community by providing a vehicle for authors wishing to publish interesting and high quality work in both fundamental and clinical veterinary medicine and science.
Veterinary Medicine and Science publishes original research articles, systematic reviews, meta-analyses, and research methods papers, along with invited editorials and commentaries. Original research papers must report well-conducted research with conclusions supported by the data presented in the paper.
We aim to be a truly global forum for high-quality research in veterinary medicine and science, and believe that the best research should be published and made widely accessible as quickly as possible. Veterinary Medicine and Science publishes papers submitted directly to the journal and those referred from a select group of prestigious journals published by Wiley-Blackwell.
Veterinary Medicine and Science is a Wiley Open Access journal, one of a new series of peer-reviewed titles publishing quality research with speed and efficiency. For further information visit the Wiley Open Access website.