The Elecsys AMH Assay Is a Suitable Method to Detect Gonadal Tissue in Male Alpacas and Llamas.

IF 1.7 3区 农林科学 Q2 VETERINARY SCIENCES
Sait Sendag, Henrik Wagner, Ali Osman Turgut, Davut Koca, Gerhard Schuler, Axel Wehrend
{"title":"The Elecsys AMH Assay Is a Suitable Method to Detect Gonadal Tissue in Male Alpacas and Llamas.","authors":"Sait Sendag, Henrik Wagner, Ali Osman Turgut, Davut Koca, Gerhard Schuler, Axel Wehrend","doi":"10.1002/vms3.70558","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>Anti-Müllerian hormone (AMH) has become an important hormonal parameter for the detection of gonadal tissue and for the diagnosis of gonadal functions and pathologies. To our knowledge, there is currently no homologous test for AMH measurements in South American camelids (SACs). Therefore, the objective of the present study was to determine serum AMH concentrations in postpubertal male alpacas and, for the first time, in llamas, using the Elecsys AMH assay kit that has not previously been tested in these species. To obtain indications of the specificity of this method in SAC, measurements were carried out in male gelding in which concentrations below the detection limit were to be expected.</p><p><strong>Methods: </strong>In this context, 37 blood samples collected by jugular venipuncture from 21 alpacas and 16 llamas were used. The obtained blood was centrifuged at 3000 g for 20 min, and the serum was stored in Eppendorf tubes at -20°C until AMH concentrations were measurement. The measurement of AMH levels was conducted in a commercial diagnostic laboratory (Laboklin, Bad Kissingen, Germany) using the electrochemiluminescence immunoassay kit Elecsys AMH run on the fully automated Cobas e 601 analyser (Roche Diagnostics Deutschland GmbH, Mannheim). The AMH test had a minimum detection limit of 0.01 ng/mL and a maximum detection limit of 23 ng/mL. The intra-assay coefficient of variation is between 2.7% and 3.3%.</p><p><strong>Results: </strong>Blood serum AMH levels ranged between 4.10 and 22 ng/mL (median: 9.80 ng/mL) and 1.79 and 10.05 ng/mL (median: 4.00) in intact alpacas (age: 6.30 ± 2.71 years; n = 10) and llamas (age: 5.50 ± 4.34; n = 8), respectively, and were significantly different between samples obtained from the two species (p < 0.05). Correlation analyses regarding an age dependence of AMH concentrations yielded negative correlation coefficients for both species but non-significant p values (alpaca: r = -0.165, p = 0.649; llama: r = -0.547, p = 0.160). In alpaca (n = 11) and llama geldings (n = 8), blood serum AMH levels were below 0.01 ng/mL (p < 0.001). These results prove that the antibodies used in the Elecsys AMH assay significantly and specifically cross-react with SAC AMH.</p><p><strong>Conclusions: </strong>In gelding llamas and alpacas, AMH concentrations were below the limit of detection (<0.01 ng/mL), which was significantly lower compared to intact animals (p < 0.001). The Elecsys AMH assay is therefore considered a suitable method for detecting gonadal tissue in SAC.</p>","PeriodicalId":23543,"journal":{"name":"Veterinary Medicine and Science","volume":"11 5","pages":"e70558"},"PeriodicalIF":1.7000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12359723/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Medicine and Science","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1002/vms3.70558","RegionNum":3,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: Anti-Müllerian hormone (AMH) has become an important hormonal parameter for the detection of gonadal tissue and for the diagnosis of gonadal functions and pathologies. To our knowledge, there is currently no homologous test for AMH measurements in South American camelids (SACs). Therefore, the objective of the present study was to determine serum AMH concentrations in postpubertal male alpacas and, for the first time, in llamas, using the Elecsys AMH assay kit that has not previously been tested in these species. To obtain indications of the specificity of this method in SAC, measurements were carried out in male gelding in which concentrations below the detection limit were to be expected.

Methods: In this context, 37 blood samples collected by jugular venipuncture from 21 alpacas and 16 llamas were used. The obtained blood was centrifuged at 3000 g for 20 min, and the serum was stored in Eppendorf tubes at -20°C until AMH concentrations were measurement. The measurement of AMH levels was conducted in a commercial diagnostic laboratory (Laboklin, Bad Kissingen, Germany) using the electrochemiluminescence immunoassay kit Elecsys AMH run on the fully automated Cobas e 601 analyser (Roche Diagnostics Deutschland GmbH, Mannheim). The AMH test had a minimum detection limit of 0.01 ng/mL and a maximum detection limit of 23 ng/mL. The intra-assay coefficient of variation is between 2.7% and 3.3%.

Results: Blood serum AMH levels ranged between 4.10 and 22 ng/mL (median: 9.80 ng/mL) and 1.79 and 10.05 ng/mL (median: 4.00) in intact alpacas (age: 6.30 ± 2.71 years; n = 10) and llamas (age: 5.50 ± 4.34; n = 8), respectively, and were significantly different between samples obtained from the two species (p < 0.05). Correlation analyses regarding an age dependence of AMH concentrations yielded negative correlation coefficients for both species but non-significant p values (alpaca: r = -0.165, p = 0.649; llama: r = -0.547, p = 0.160). In alpaca (n = 11) and llama geldings (n = 8), blood serum AMH levels were below 0.01 ng/mL (p < 0.001). These results prove that the antibodies used in the Elecsys AMH assay significantly and specifically cross-react with SAC AMH.

Conclusions: In gelding llamas and alpacas, AMH concentrations were below the limit of detection (<0.01 ng/mL), which was significantly lower compared to intact animals (p < 0.001). The Elecsys AMH assay is therefore considered a suitable method for detecting gonadal tissue in SAC.

Abstract Image

Abstract Image

Abstract Image

Elecsys AMH法是一种检测雄性羊驼和大羊驼性腺组织的合适方法。
目的:抗勒氏激素(anti - lerian hormone, AMH)已成为性腺组织检测和性腺功能及病理诊断的重要激素参数。据我们所知,目前在南美骆驼(SACs)中没有AMH测量的同源测试。因此,本研究的目的是测定青春期后雄性羊驼的血清AMH浓度,并首次使用Elecsys AMH检测试剂盒测定羊驼的血清AMH浓度,该试剂盒此前未在这些物种中进行过测试。为了获得该方法在SAC中的特异性指示,在浓度低于检测限的雄性骟马中进行了测量。方法:采用颈静脉穿刺法采集21头羊驼和16头大羊驼37份血样。取血3000g离心20 min,血清保存于-20℃Eppendorf管中,待测定AMH浓度。AMH水平的测量在商业诊断实验室(Laboklin, Bad Kissingen, Germany)进行,使用电化学发光免疫测定试剂盒Elecsys AMH在全自动Cobas e 601分析仪(Roche Diagnostics Deutschland GmbH, Mannheim)上运行。AMH试验最低检出限为0.01 ng/mL,最高检出限为23 ng/mL。试验内变异系数在2.7% ~ 3.3%之间。结果:完整羊驼(年龄:6.30±2.71岁,n = 10)和大羊驼(年龄:5.50±4.34岁,n = 8)的血清AMH水平分别为4.10 ~ 22 ng/mL(中位数:9.80 ng/mL)和1.79 ~ 10.05 ng/mL(中位数:4.00),且两种样品之间存在显著差异(p)。结论:在阉割的大羊驼和大羊驼中,AMH浓度均低于检测限(
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary Medicine and Science
Veterinary Medicine and Science Veterinary-General Veterinary
CiteScore
3.00
自引率
0.00%
发文量
296
期刊介绍: Veterinary Medicine and Science is the peer-reviewed journal for rapid dissemination of research in all areas of veterinary medicine and science. The journal aims to serve the research community by providing a vehicle for authors wishing to publish interesting and high quality work in both fundamental and clinical veterinary medicine and science. Veterinary Medicine and Science publishes original research articles, systematic reviews, meta-analyses, and research methods papers, along with invited editorials and commentaries. Original research papers must report well-conducted research with conclusions supported by the data presented in the paper. We aim to be a truly global forum for high-quality research in veterinary medicine and science, and believe that the best research should be published and made widely accessible as quickly as possible. Veterinary Medicine and Science publishes papers submitted directly to the journal and those referred from a select group of prestigious journals published by Wiley-Blackwell. Veterinary Medicine and Science is a Wiley Open Access journal, one of a new series of peer-reviewed titles publishing quality research with speed and efficiency. For further information visit the Wiley Open Access website.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信