IvmeRad: An Active Personal Wearable Ionizing Radiation Dosimeter and Results From a Human Suborbital Space Flight

IF 1.9 3区 工程技术 Q3 ENGINEERING, ELECTRICAL & ELECTRONIC
Selcen Uzun Duran;Gupse Aksöz;Egecan Karadöller;Ümit Alver;Tuva C. Atasever;Ömer Ataş;M. Bilge Demirköz
{"title":"IvmeRad: An Active Personal Wearable Ionizing Radiation Dosimeter and Results From a Human Suborbital Space Flight","authors":"Selcen Uzun Duran;Gupse Aksöz;Egecan Karadöller;Ümit Alver;Tuva C. Atasever;Ömer Ataş;M. Bilge Demirköz","doi":"10.1109/TNS.2025.3588686","DOIUrl":null,"url":null,"abstract":"IvmeRad is an active personal wearable radiation dosimeter. IvmeRad-S is a modified version of the device that was carried by a Turkish astronaut on a suborbital space flight up to an altitude of 87,548 km on June 8, 2024, with Virgin Galactic. During the flight, which lasted 70 min, radiation exposure of the astronaut was measured and analyzed. In this study, the design and calibration of the Geiger–Müller detector alongside the performance of the integrated device are investigated, and data are presented and compared to Civil Aeromedical Research Institute 7A (CARI-7A), Model for Atmospheric Ionizing Radiation Effect (MAIRE), and QinetiQ Atmospheric Radiation Model (QARM) calculation codes. A comparison of different calculation codes shows different H*(10) ambient equivalent dose rate behavior above 20 km. These differences could be attributed to the high radiation weighting factor of heavy ions and modeling differences of incident ionizing particles. Also, dependencies on detector characteristics and calibration are discussed to compare calculations with measured dose rates.","PeriodicalId":13406,"journal":{"name":"IEEE Transactions on Nuclear Science","volume":"72 8","pages":"2542-2547"},"PeriodicalIF":1.9000,"publicationDate":"2025-07-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Nuclear Science","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/11079724/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

IvmeRad is an active personal wearable radiation dosimeter. IvmeRad-S is a modified version of the device that was carried by a Turkish astronaut on a suborbital space flight up to an altitude of 87,548 km on June 8, 2024, with Virgin Galactic. During the flight, which lasted 70 min, radiation exposure of the astronaut was measured and analyzed. In this study, the design and calibration of the Geiger–Müller detector alongside the performance of the integrated device are investigated, and data are presented and compared to Civil Aeromedical Research Institute 7A (CARI-7A), Model for Atmospheric Ionizing Radiation Effect (MAIRE), and QinetiQ Atmospheric Radiation Model (QARM) calculation codes. A comparison of different calculation codes shows different H*(10) ambient equivalent dose rate behavior above 20 km. These differences could be attributed to the high radiation weighting factor of heavy ions and modeling differences of incident ionizing particles. Also, dependencies on detector characteristics and calibration are discussed to compare calculations with measured dose rates.
一种主动个人可穿戴电离辐射剂量计和人类亚轨道太空飞行的结果
IvmeRad是一种主动的个人可穿戴辐射剂量计。IvmeRad-S是由土耳其宇航员于2024年6月8日与维珍银河公司一起进行亚轨道太空飞行,高度为87,548公里的设备的改进版本。在持续70分钟的飞行中,对宇航员的辐射暴露进行了测量和分析。本文研究了盖格-米勒探测器的设计和标定以及集成装置的性能,并提供了数据,并与民用航空医学研究所7A (CARI-7A)、大气电离辐射效应模型(MAIRE)和QinetiQ大气辐射模型(QARM)计算代码进行了比较。通过对不同计算程序的比较,得出了20 km以上H*(10)环境当量剂量率的不同行为。这些差异可归因于重离子的高辐射加权因子和入射电离粒子的模拟差异。此外,还讨论了对检测器特性和校准的依赖,以便将计算结果与测量剂量率进行比较。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Nuclear Science
IEEE Transactions on Nuclear Science 工程技术-工程:电子与电气
CiteScore
3.70
自引率
27.80%
发文量
314
审稿时长
6.2 months
期刊介绍: The IEEE Transactions on Nuclear Science is a publication of the IEEE Nuclear and Plasma Sciences Society. It is viewed as the primary source of technical information in many of the areas it covers. As judged by JCR impact factor, TNS consistently ranks in the top five journals in the category of Nuclear Science & Technology. It has one of the higher immediacy indices, indicating that the information it publishes is viewed as timely, and has a relatively long citation half-life, indicating that the published information also is viewed as valuable for a number of years. The IEEE Transactions on Nuclear Science is published bimonthly. Its scope includes all aspects of the theory and application of nuclear science and engineering. It focuses on instrumentation for the detection and measurement of ionizing radiation; particle accelerators and their controls; nuclear medicine and its application; effects of radiation on materials, components, and systems; reactor instrumentation and controls; and measurement of radiation in space.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信