Optical coherence tomography in endovascular neurosurgery: current applications and future directions

IF 1.8 4区 医学 Q3 CLINICAL NEUROLOGY
Ioannis Karavolias , Joanna M. Roy , Basel Musmar , Stavropoula I. Tjoumakaris , M. Reid Gooch , Robert H. Rosenwasser , Pascal M. Jabbour
{"title":"Optical coherence tomography in endovascular neurosurgery: current applications and future directions","authors":"Ioannis Karavolias ,&nbsp;Joanna M. Roy ,&nbsp;Basel Musmar ,&nbsp;Stavropoula I. Tjoumakaris ,&nbsp;M. Reid Gooch ,&nbsp;Robert H. Rosenwasser ,&nbsp;Pascal M. Jabbour","doi":"10.1016/j.jocn.2025.111563","DOIUrl":null,"url":null,"abstract":"<div><div>Optical Coherence Tomography (OCT), initially introduced in 1991, has demonstrated efficacy in diagnosing pathologies of the retina, optic nerve, and coronary vessels. Recently, there has been growing research interest in the application of OCT in endovascular neurosurgery, with studies exploring its utility across a range of intracranial and extracranial endovascular diseases. The current review aims to synthesize available literature on the use of OCT in endovascular neurosurgery, encompassing both clinical and preclinical models. 57 studies met the inclusion criteria and were included in the qualitative analysis. These studies were stratified into different categories based on diseases studied. OCT has been utilized to evaluate the in vivo microanatomy of intracranial and extracranial vasculature, assess treatment efficacy and device apposition, and monitor patient outcomes. The results consistently demonstrate greater accuracy and stronger correlation with patient outcomes compared to contemporary imaging techniques. However, limitations such as the large size of current OCT-integrated probes and the lack of standardized workflows hinder the broader adoption of this technology.</div></div>","PeriodicalId":15487,"journal":{"name":"Journal of Clinical Neuroscience","volume":"141 ","pages":"Article 111563"},"PeriodicalIF":1.8000,"publicationDate":"2025-08-20","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Clinical Neuroscience","FirstCategoryId":"3","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0967586825005363","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"CLINICAL NEUROLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Optical Coherence Tomography (OCT), initially introduced in 1991, has demonstrated efficacy in diagnosing pathologies of the retina, optic nerve, and coronary vessels. Recently, there has been growing research interest in the application of OCT in endovascular neurosurgery, with studies exploring its utility across a range of intracranial and extracranial endovascular diseases. The current review aims to synthesize available literature on the use of OCT in endovascular neurosurgery, encompassing both clinical and preclinical models. 57 studies met the inclusion criteria and were included in the qualitative analysis. These studies were stratified into different categories based on diseases studied. OCT has been utilized to evaluate the in vivo microanatomy of intracranial and extracranial vasculature, assess treatment efficacy and device apposition, and monitor patient outcomes. The results consistently demonstrate greater accuracy and stronger correlation with patient outcomes compared to contemporary imaging techniques. However, limitations such as the large size of current OCT-integrated probes and the lack of standardized workflows hinder the broader adoption of this technology.
光学相干断层扫描在血管内神经外科:目前的应用和未来的方向
光学相干断层扫描(OCT)于1991年首次引入,在诊断视网膜、视神经和冠状血管病变方面已经证明了其有效性。近年来,人们对OCT在血管内神经外科中的应用越来越感兴趣,研究探索了它在一系列颅内和颅外血管内疾病中的应用。本综述旨在综合有关OCT在血管内神经外科手术中的应用的现有文献,包括临床和临床前模型。57项研究符合纳入标准,纳入定性分析。这些研究根据所研究的疾病被分为不同的类别。OCT已被用于评估颅内和颅外血管的体内显微解剖,评估治疗效果和装置的放置,并监测患者的预后。与当代成像技术相比,结果一致显示出更高的准确性和与患者预后更强的相关性。然而,诸如当前oct集成探头的大尺寸和缺乏标准化工作流程等限制阻碍了该技术的广泛采用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Clinical Neuroscience
Journal of Clinical Neuroscience 医学-临床神经学
CiteScore
4.50
自引率
0.00%
发文量
402
审稿时长
40 days
期刊介绍: This International journal, Journal of Clinical Neuroscience, publishes articles on clinical neurosurgery and neurology and the related neurosciences such as neuro-pathology, neuro-radiology, neuro-ophthalmology and neuro-physiology. The journal has a broad International perspective, and emphasises the advances occurring in Asia, the Pacific Rim region, Europe and North America. The Journal acts as a focus for publication of major clinical and laboratory research, as well as publishing solicited manuscripts on specific subjects from experts, case reports and other information of interest to clinicians working in the clinical neurosciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信