Examining Circumferential Bone Stability around Narrow-Diameter Implants Retaining Mandibular Overdentures: A Three-Year Longitudinal Analysis.

IF 1.8
Victória Klumb, Salma Rose Buchnveitz Salybi, Lucas Jardim da Silva, Laura Lourenço Morel, Anna Paula da Rosa Possebon, Alessandra Julie Schuster, Luciana de Rezende Pinto, Fernanda Faot
{"title":"Examining Circumferential Bone Stability around Narrow-Diameter Implants Retaining Mandibular Overdentures: A Three-Year Longitudinal Analysis.","authors":"Victória Klumb, Salma Rose Buchnveitz Salybi, Lucas Jardim da Silva, Laura Lourenço Morel, Anna Paula da Rosa Possebon, Alessandra Julie Schuster, Luciana de Rezende Pinto, Fernanda Faot","doi":"10.11607/ijp.9432","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>This longitudinal study investigated the relationship between secondary stability and circumferential bone level of narrow diameter implants to retain mandibular overdentures (MO) after 1 and 3 years.</p><p><strong>Materials and methods: </strong>Thirty patients (19 men, 11 women) with a mean age of 67.5 were monitored by the implant stability coefficient (ISQ) and the vertical (VBL) and horizontal (HBL) bone level assessed by CBCT were measured on the 4 implant faces. Two-way ANOVA with repeated measures followed by Sidak's post-hoc test was used to compare ISQ, VBL and HBL over time and between faces.</p><p><strong>Results: </strong>The linearity and association between ISQ and VBL and HBL were analyzed by Spearmann's correlation and linear regression tests. ISQ, VBL and HBL did not differ significantly over time (p≥0.05). The comparison between the faces showed that only VBL presented significant differences (p≤0.05) at 1 and 3 years between the following faces: distal and mesial; lingual and mesial; and mesial and buccal. A positive and moderate correlation was observed between ISQ and HBL of the lingual (r=0.502; p<0.01) and mesial (r=0.536; p<0.01) faces at 1 year. The VBL of the mesial face, HBL of the mesial and lingual faces and the overall HBL at 1 year were associated with the ISQ values obtained on these faces.</p><p><strong>Conclusion: </strong>VBL and HBL remained stable across all implant faces over the 3-year follow-up period. Nevertheless, the lingual face demonstrated the greatest VBL, whereas the mesial face exhibited the highest stability, with minimal VBL observed in the third year. Early bone remodeling, particularly during the first year of OM use, may affect implant stability and appears to be associated with HBL changes on the lingual and mesial faces.</p>","PeriodicalId":94232,"journal":{"name":"The International journal of prosthodontics","volume":"0 0","pages":"1-22"},"PeriodicalIF":1.8000,"publicationDate":"2025-08-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"The International journal of prosthodontics","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.11607/ijp.9432","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: This longitudinal study investigated the relationship between secondary stability and circumferential bone level of narrow diameter implants to retain mandibular overdentures (MO) after 1 and 3 years.

Materials and methods: Thirty patients (19 men, 11 women) with a mean age of 67.5 were monitored by the implant stability coefficient (ISQ) and the vertical (VBL) and horizontal (HBL) bone level assessed by CBCT were measured on the 4 implant faces. Two-way ANOVA with repeated measures followed by Sidak's post-hoc test was used to compare ISQ, VBL and HBL over time and between faces.

Results: The linearity and association between ISQ and VBL and HBL were analyzed by Spearmann's correlation and linear regression tests. ISQ, VBL and HBL did not differ significantly over time (p≥0.05). The comparison between the faces showed that only VBL presented significant differences (p≤0.05) at 1 and 3 years between the following faces: distal and mesial; lingual and mesial; and mesial and buccal. A positive and moderate correlation was observed between ISQ and HBL of the lingual (r=0.502; p<0.01) and mesial (r=0.536; p<0.01) faces at 1 year. The VBL of the mesial face, HBL of the mesial and lingual faces and the overall HBL at 1 year were associated with the ISQ values obtained on these faces.

Conclusion: VBL and HBL remained stable across all implant faces over the 3-year follow-up period. Nevertheless, the lingual face demonstrated the greatest VBL, whereas the mesial face exhibited the highest stability, with minimal VBL observed in the third year. Early bone remodeling, particularly during the first year of OM use, may affect implant stability and appears to be associated with HBL changes on the lingual and mesial faces.

窄径种植体下颌覆盖义齿周骨稳定性研究:三年纵向分析。
目的:研究窄径种植体保留下颌覆盖义齿(MO) 1年和3年后二级稳定性与周向骨水平的关系。材料与方法:30例患者(男19例,女11例),平均年龄67.5岁,采用种植体稳定系数(ISQ)监测种植体4个面CBCT评估的垂直(VBL)和水平(HBL)骨水平。采用重复测量的双向方差分析和Sidak事后检验来比较不同时间和不同面孔之间的ISQ、VBL和HBL。结果:采用Spearmann相关检验和线性回归检验,分析ISQ与VBL、HBL之间的线性关系和相关关系。各组间ISQ、VBL、HBL差异无统计学意义(p≥0.05)。面部间比较显示,在1年和3年时,只有VBL在以下面部间存在显著差异(p≤0.05):远端与中端;舌和中缘;还有内侧和颊部。ISQ与舌部HBL呈正相关(r=0.502;结论:在3年的随访期间,所有种植体面VBL和HBL保持稳定。然而,舌面表现出最大的VBL,而内侧面表现出最高的稳定性,在第三年观察到最小的VBL。早期骨重塑,特别是在OM使用的第一年,可能会影响种植体的稳定性,并且似乎与舌面和内侧面HBL的变化有关。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信