Relationship between endotoxin core and staphylococcal antibody levels and outcome following transcatheter aortic valve implantation (TAVI).

IF 2.1 3区 医学 Q2 ANESTHESIOLOGY
Andrew Smith, James Fullerton, John Whittle, James Moon, Michael Mullen, Paul Scully, Colin Hamilton-Davies
{"title":"Relationship between endotoxin core and staphylococcal antibody levels and outcome following transcatheter aortic valve implantation (TAVI).","authors":"Andrew Smith, James Fullerton, John Whittle, James Moon, Michael Mullen, Paul Scully, Colin Hamilton-Davies","doi":"10.1186/s13741-024-00464-x","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Morbidity and mortality following aortic valve surgery is high. Low antibody levels to endotoxin core and to staphylococcus is associated with poor outcome following cardiac surgery. Transcatheter aortic valve implantation (TAVI) is an alternative treatment to surgery. This study examines the relationship between antibody levels and outcome following TAVI.</p><p><strong>Methods: </strong>Using enzyme-linked immunosorbent assays (ELISA), we measured pre-procedure levels of antibodies to endotoxin core (EndoCAb) and 2 common staphylococcal epitopes on saved serum of 112 adult patients scheduled to undergo elective TAVI. Primary outcome measure was post-procedure length of stay (LOS) in hospital with secondary outcome being development of infective complications. Correlations were examined using Spearman rank order or Kendall Tau-b methods. Patients were quartiled according to antibody levels and outcomes compared between quartile groups. Differences between groups were examined using Student t-test, one-way ANOVA, and Kruskal-Wallis tests.</p><p><strong>Results: </strong>One hundred twenty-two patients (64 M, 58 F) were recruited with mean age of 86 years. Little correlation was seen between any of the individual antibody levels or combined ranked antibody level with length of stay following TAVI (correlation coefficients-teichoic acid r<sup>2</sup> = 0.02, alpha-toxin r<sup>2</sup> = 0.02, EndoCAb r<sup>2</sup> < 0.02, combined rank r<sup>2</sup> = 0.03). When groups were quartiled, there was little difference between median length of stay across all quartiles for each antibody (ANOVA-teichoic acid p = 0.153, alpha-toxin p = 0.332, EndoCAb p = 0.848, combined rank p = 0.374). There were no differences in the number developing post-operative infections between the quartiles for each antibody type (ANOVA-teichoic acid p = 0.994, alpha-toxin p = 0.962, EndoCAb p = 0.918, combined rank p = 0.855).</p><p><strong>Conclusions: </strong>This study indicates that there is little association between post-procedural length of stay in hospital following TAVI and pre-procedural antibody levels to endotoxin or staphylococcus, unlike that seen with surgical patients. Understanding this relationship may enable improved selection of therapeutic options for patients with impaired immunity needing aortic valve interventions.</p><p><strong>Trial registration: </strong>The patients in this study are a sub-group of a larger observational cohort study looking at the prevalence of cardiac amyloid in the elderly with aortic stenosis in those patients undergoing transcatheter aortic valve replacement.</p><p><strong>Clinicaltrials: </strong>gov Identifier: NCT03029026.</p>","PeriodicalId":19764,"journal":{"name":"Perioperative Medicine","volume":"14 1","pages":"87"},"PeriodicalIF":2.1000,"publicationDate":"2025-08-14","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12351906/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Perioperative Medicine","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s13741-024-00464-x","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ANESTHESIOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Morbidity and mortality following aortic valve surgery is high. Low antibody levels to endotoxin core and to staphylococcus is associated with poor outcome following cardiac surgery. Transcatheter aortic valve implantation (TAVI) is an alternative treatment to surgery. This study examines the relationship between antibody levels and outcome following TAVI.

Methods: Using enzyme-linked immunosorbent assays (ELISA), we measured pre-procedure levels of antibodies to endotoxin core (EndoCAb) and 2 common staphylococcal epitopes on saved serum of 112 adult patients scheduled to undergo elective TAVI. Primary outcome measure was post-procedure length of stay (LOS) in hospital with secondary outcome being development of infective complications. Correlations were examined using Spearman rank order or Kendall Tau-b methods. Patients were quartiled according to antibody levels and outcomes compared between quartile groups. Differences between groups were examined using Student t-test, one-way ANOVA, and Kruskal-Wallis tests.

Results: One hundred twenty-two patients (64 M, 58 F) were recruited with mean age of 86 years. Little correlation was seen between any of the individual antibody levels or combined ranked antibody level with length of stay following TAVI (correlation coefficients-teichoic acid r2 = 0.02, alpha-toxin r2 = 0.02, EndoCAb r2 < 0.02, combined rank r2 = 0.03). When groups were quartiled, there was little difference between median length of stay across all quartiles for each antibody (ANOVA-teichoic acid p = 0.153, alpha-toxin p = 0.332, EndoCAb p = 0.848, combined rank p = 0.374). There were no differences in the number developing post-operative infections between the quartiles for each antibody type (ANOVA-teichoic acid p = 0.994, alpha-toxin p = 0.962, EndoCAb p = 0.918, combined rank p = 0.855).

Conclusions: This study indicates that there is little association between post-procedural length of stay in hospital following TAVI and pre-procedural antibody levels to endotoxin or staphylococcus, unlike that seen with surgical patients. Understanding this relationship may enable improved selection of therapeutic options for patients with impaired immunity needing aortic valve interventions.

Trial registration: The patients in this study are a sub-group of a larger observational cohort study looking at the prevalence of cardiac amyloid in the elderly with aortic stenosis in those patients undergoing transcatheter aortic valve replacement.

Clinicaltrials: gov Identifier: NCT03029026.

经导管主动脉瓣植入术(TAVI)后内毒素核心和葡萄球菌抗体水平与预后的关系。
背景:主动脉瓣手术后的发病率和死亡率很高。对内毒素核心和葡萄球菌的低抗体水平与心脏手术后不良预后相关。经导管主动脉瓣植入术(TAVI)是一种替代手术的治疗方法。本研究探讨抗体水平与TAVI后预后之间的关系。方法:采用酶联免疫吸附试验(ELISA)测定112例计划接受选择性TAVI的成人患者保存的血清中内毒素核心抗体(EndoCAb)和2个常见葡萄球菌表位的术前水平。主要指标是术后住院时间(LOS),次要指标是感染并发症的发生。使用Spearman秩序或Kendall Tau-b方法检验相关性。根据抗体水平和四分位组间比较的结果对患者进行四分位。组间差异采用学生t检验、单因素方差分析和Kruskal-Wallis检验。结果:共纳入122例患者(男64例,女58例),平均年龄86岁。个体抗体水平或综合抗体水平与TAVI术后住院时间均无显著相关性(相关系数-胆酸r2 = 0.02, α -毒素r2 = 0.02, EndoCAb r2 = 0.03)。对各组进行四分位数划分时,每种抗体在所有四分位数上的停留时间中位数差异不大(方差分析-teichoic acid p = 0.153, α -toxin p = 0.332, EndoCAb p = 0.848,综合等级p = 0.374)。各抗体类型的术后感染发生数量在四分位数之间无差异(方差分析-胆酸p = 0.994, α毒素p = 0.962, EndoCAb p = 0.918,综合秩p = 0.855)。结论:本研究表明,与手术患者不同,TAVI术后住院时间与术前内毒素或葡萄球菌抗体水平之间的关系不大。了解这种关系可以使需要主动脉瓣介入治疗的免疫受损患者更好地选择治疗方案。试验注册:本研究中的患者是一项更大的观察性队列研究的一个亚组,该研究旨在观察经导管主动脉瓣置换术的老年主动脉瓣狭窄患者中心脏淀粉样蛋白的患病率。临床试验:gov标识符:NCT03029026。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
3.80%
发文量
55
审稿时长
10 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信