Technical Recommendation on Multi-Driver Multifrequency MR Elastography for Tomographic Mapping of Abdominal Stiffness With a Focus on the Pancreas and Pancreatic Ductal Adenocarcinoma.

IF 8 1区 医学 Q1 RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
Jakob Schattenfroh, Salma Almutawakel, Jan Bieling, Johannes Castelein, Melanie Estrella, Philippe Garteiser, Viktor Hartung, Karl H Hillebrandt, Adrian T Huber, Laura Körner, Thomas Kröncke, Thomas Malinka, Hans-Jonas Meyer, Tom Meyer, Uwe Pelzer, Felix Pfister, Igor M Sauer, Anna Speth, Bernard E Van Beers, Carsten Warmuth, Nienke P M Wassenaar, Yanglei Wu, Rolf Otto Reiter, Ingolf Sack
{"title":"Technical Recommendation on Multi-Driver Multifrequency MR Elastography for Tomographic Mapping of Abdominal Stiffness With a Focus on the Pancreas and Pancreatic Ductal Adenocarcinoma.","authors":"Jakob Schattenfroh, Salma Almutawakel, Jan Bieling, Johannes Castelein, Melanie Estrella, Philippe Garteiser, Viktor Hartung, Karl H Hillebrandt, Adrian T Huber, Laura Körner, Thomas Kröncke, Thomas Malinka, Hans-Jonas Meyer, Tom Meyer, Uwe Pelzer, Felix Pfister, Igor M Sauer, Anna Speth, Bernard E Van Beers, Carsten Warmuth, Nienke P M Wassenaar, Yanglei Wu, Rolf Otto Reiter, Ingolf Sack","doi":"10.1097/RLI.0000000000001231","DOIUrl":null,"url":null,"abstract":"<p><strong>Objectives: </strong>MR elastography (MRE) offers valuable mechanical tissue characterization for clinical diagnosis. However, conventional single-driver, single-frequency MRE systems are often limited by insufficient coverage of deep-seated organs like the pancreas. This study investigates whether multiplex MRE using multiple drivers and vibration frequencies can overcome these limitations.</p><p><strong>Materials and methods: </strong>This prospective study used single-shot spin-echo MRE in 18 healthy volunteers (mean age 30±8 y) targeting the liver, pancreas, kidneys, and spleen. Each healthy volunteer underwent 16 MRE examinations with different sets of 4 vibration frequencies in the range of 30 to 60 Hz and 4 driver combinations, and an additional null experiment without vibrations. In addition, a cohort of 14 patients with pancreatic ductal adenocarcinoma (PDAC, mean age 57±15 y) were retrospectively assessed. The quality of shear-wave fields and stiffness maps were assessed in terms of displacement amplitudes and image sharpness.</p><p><strong>Results: </strong>In healthy volunteers, abdominal coverage with displacement amplitudes above the pre-determined noise level of 4 µm varied among the MRE investigated: 24.2% (0.0% to 56.2%, single-driver at 60 Hz), 66.9% (24.8% to 97.7%, single-driver at 30 to 60 Hz), 70.2% (0.0% to 92.5%, multi-driver at 60 Hz), and 99.9% (89.4% to 100%, multi-driver at 30 to 60 Hz). In the pancreas, more than 60% coverage was achieved in all subjects using 4 drivers and multiple frequencies. This was achieved in only 2 of 18 subjects (11%) using single-driver/single-frequency MRE. Superficial organs were adequately assessed with all configurations. In patients with PDAC, multi-driver MRE at 30 to 60 Hz achieved 99.1% (91.4% to 100%) coverage of the pancreas and 96.3% (63.1% to 100%) abdominal coverage, suggesting that tomographic stiffness mapping is clinically feasible.</p><p><strong>Conclusion: </strong>MRE with at least 4 drivers and multiple vibration frequencies in the range of 30 to 60 Hz enables tomographic mapping of tissue stiffness across the entire abdomen, including the pancreas. Our results thus indicate that multiplex MRE is a promising approach for generating detailed images of abdominal stiffness that can improve clinical diagnosis of abdominal and pancreatic diseases.</p>","PeriodicalId":14486,"journal":{"name":"Investigative Radiology","volume":" ","pages":""},"PeriodicalIF":8.0000,"publicationDate":"2025-08-25","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Investigative Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1097/RLI.0000000000001231","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives: MR elastography (MRE) offers valuable mechanical tissue characterization for clinical diagnosis. However, conventional single-driver, single-frequency MRE systems are often limited by insufficient coverage of deep-seated organs like the pancreas. This study investigates whether multiplex MRE using multiple drivers and vibration frequencies can overcome these limitations.

Materials and methods: This prospective study used single-shot spin-echo MRE in 18 healthy volunteers (mean age 30±8 y) targeting the liver, pancreas, kidneys, and spleen. Each healthy volunteer underwent 16 MRE examinations with different sets of 4 vibration frequencies in the range of 30 to 60 Hz and 4 driver combinations, and an additional null experiment without vibrations. In addition, a cohort of 14 patients with pancreatic ductal adenocarcinoma (PDAC, mean age 57±15 y) were retrospectively assessed. The quality of shear-wave fields and stiffness maps were assessed in terms of displacement amplitudes and image sharpness.

Results: In healthy volunteers, abdominal coverage with displacement amplitudes above the pre-determined noise level of 4 µm varied among the MRE investigated: 24.2% (0.0% to 56.2%, single-driver at 60 Hz), 66.9% (24.8% to 97.7%, single-driver at 30 to 60 Hz), 70.2% (0.0% to 92.5%, multi-driver at 60 Hz), and 99.9% (89.4% to 100%, multi-driver at 30 to 60 Hz). In the pancreas, more than 60% coverage was achieved in all subjects using 4 drivers and multiple frequencies. This was achieved in only 2 of 18 subjects (11%) using single-driver/single-frequency MRE. Superficial organs were adequately assessed with all configurations. In patients with PDAC, multi-driver MRE at 30 to 60 Hz achieved 99.1% (91.4% to 100%) coverage of the pancreas and 96.3% (63.1% to 100%) abdominal coverage, suggesting that tomographic stiffness mapping is clinically feasible.

Conclusion: MRE with at least 4 drivers and multiple vibration frequencies in the range of 30 to 60 Hz enables tomographic mapping of tissue stiffness across the entire abdomen, including the pancreas. Our results thus indicate that multiplex MRE is a promising approach for generating detailed images of abdominal stiffness that can improve clinical diagnosis of abdominal and pancreatic diseases.

多驱动多频磁共振弹性成像腹部僵硬层析成像技术建议,重点是胰腺和胰腺导管腺癌。
目的:磁共振弹性成像(MRE)为临床诊断提供有价值的机械组织特征。然而,传统的单驱动、单频MRE系统往往受到胰腺等深层器官覆盖范围不足的限制。本研究将探讨使用多个驱动和振动频率的多路MRE能否克服这些限制。材料和方法:本前瞻性研究采用单次旋转回声MRE对18名健康志愿者(平均年龄30±8岁)的肝脏、胰腺、肾脏和脾脏进行扫描。每个健康的志愿者都接受了16次MRE检查,其中包括4组不同的振动频率(30至60赫兹)和4种驱动组合,以及另外一次没有振动的零实验。此外,对14例胰腺导管腺癌患者(PDAC,平均年龄57±15岁)进行回顾性评估。根据位移幅度和图像清晰度评估了剪切波场和刚度图的质量。结果:在健康志愿者中,位移幅度高于预定噪声水平4µm的腹部覆盖率在被调查的MRE中有所不同:24.2%(0.0%至56.2%,单驱动60 Hz), 66.9%(24.8%至97.7%,单驱动30至60 Hz), 70.2%(0.0%至92.5%,多驱动60 Hz)和99.9%(89.4%至100%,多驱动30至60 Hz)。在胰腺,使用4个驱动器和多个频率,所有受试者的覆盖率超过60%。使用单驱动/单频MRE的18名受试者中只有2名(11%)实现了这一目标。浅表器官在所有构型下均得到充分评估。在PDAC患者中,30至60 Hz的多驱动器MRE对胰腺的覆盖率达到99.1%(91.4%至100%),对腹部的覆盖率达到96.3%(63.1%至100%),这表明断层扫描刚度定位在临床上是可行的。结论:MRE具有至少4个驱动器和30至60 Hz范围内的多个振动频率,可以对包括胰腺在内的整个腹部的组织刚度进行层析成像。因此,我们的研究结果表明,多重MRE是一种很有前途的方法,可以产生腹部僵硬的详细图像,可以改善腹部和胰腺疾病的临床诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Investigative Radiology
Investigative Radiology 医学-核医学
CiteScore
15.10
自引率
16.40%
发文量
188
审稿时长
4-8 weeks
期刊介绍: Investigative Radiology publishes original, peer-reviewed reports on clinical and laboratory investigations in diagnostic imaging, the diagnostic use of radioactive isotopes, computed tomography, positron emission tomography, magnetic resonance imaging, ultrasound, digital subtraction angiography, and related modalities. Emphasis is on early and timely publication. Primarily research-oriented, the journal also includes a wide variety of features of interest to clinical radiologists.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信