Development of a reusable and disposable sensor for the rapid determination of the human chorionic gonadotropin (hCG) biomarker

IF 3.3 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Analyst Pub Date : 2025-08-15 DOI:10.1039/D5AN00663E
Andrei N. Stephen and Subrayal M. Reddy
{"title":"Development of a reusable and disposable sensor for the rapid determination of the human chorionic gonadotropin (hCG) biomarker","authors":"Andrei N. Stephen and Subrayal M. Reddy","doi":"10.1039/D5AN00663E","DOIUrl":null,"url":null,"abstract":"<p >Herein, we developed a previously undescribed electrochemical nanoMIP-based sensor for the sensitive, reusable and accurate determination of human chorionic gonadotropin (hCG). Using a proprietary rapid and scalable method, hCG-selective polyacrylamide nanoMIP particles were produced within 2 h in high yields of 11 mg per 1 mL reaction batch with hCG-modified magnetic nanoparticles (MNPs@CHO@hCG). The MNPs were reusable for 5 sequential cycles of nanoMIP production. The nanoMIPs were integrated with gold screen printed electrodes by electropolymerisation within an electrochemically grown polyacrylamide layer. The ensuing hCG sensor was characterised using cyclic voltammetry and electrochemical impedance spectroscopy. Both electrochemical modes were shown to be suitable for determining the selective binding of the biomarker. The sensor was also tested using a non-target protein (SARS-CoV-2 nucleocapsid protein) and was shown to be 20× more selective for target hCG compared with the non-target. The linear range was shown to be 1.5–384 mIU with a LOD of 3 mIU and saturation occurring beyond 1000 mIU. We also electrochemically determined the equilibrium dissociation constant (K<small><sub>D</sub></small>) to be 1.4 × 10<small><sup>−10</sup></small> M using EIS, which is on par with monoclonal antibodies produced for hCG. Sensor reusability studies demonstrated that the same sensor, once regenerated after sodium dodecyl sulphate/acetic acid treatment, could be used for 3 subsequent measurements. We present an effective method that can be used for both pregnancy testing and testicular cancer monitoring.</p>","PeriodicalId":63,"journal":{"name":"Analyst","volume":" 19","pages":" 4293-4303"},"PeriodicalIF":3.3000,"publicationDate":"2025-08-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2025/an/d5an00663e?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analyst","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/an/d5an00663e","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Herein, we developed a previously undescribed electrochemical nanoMIP-based sensor for the sensitive, reusable and accurate determination of human chorionic gonadotropin (hCG). Using a proprietary rapid and scalable method, hCG-selective polyacrylamide nanoMIP particles were produced within 2 h in high yields of 11 mg per 1 mL reaction batch with hCG-modified magnetic nanoparticles (MNPs@CHO@hCG). The MNPs were reusable for 5 sequential cycles of nanoMIP production. The nanoMIPs were integrated with gold screen printed electrodes by electropolymerisation within an electrochemically grown polyacrylamide layer. The ensuing hCG sensor was characterised using cyclic voltammetry and electrochemical impedance spectroscopy. Both electrochemical modes were shown to be suitable for determining the selective binding of the biomarker. The sensor was also tested using a non-target protein (SARS-CoV-2 nucleocapsid protein) and was shown to be 20× more selective for target hCG compared with the non-target. The linear range was shown to be 1.5–384 mIU with a LOD of 3 mIU and saturation occurring beyond 1000 mIU. We also electrochemically determined the equilibrium dissociation constant (KD) to be 1.4 × 10−10 M using EIS, which is on par with monoclonal antibodies produced for hCG. Sensor reusability studies demonstrated that the same sensor, once regenerated after sodium dodecyl sulphate/acetic acid treatment, could be used for 3 subsequent measurements. We present an effective method that can be used for both pregnancy testing and testicular cancer monitoring.

Abstract Image

用于快速测定人绒毛膜促性腺激素(hCG)生物标志物的可重复使用一次性传感器的研制
在此,我们开发了一种基于电化学纳米omip的传感器,用于灵敏,可重复使用和准确测定人绒毛膜促性腺激素(hCG)。使用专有的快速和可扩展的方法,在hCG修饰的磁性纳米颗粒(MNPs@CHO@hCG)上以每1ml反应批11 mg的高收率在2小时内生产出hCG选择性聚丙烯酰胺纳米omip颗粒。MNPs可重复使用5个连续的纳米omip生产周期。在电化学生长的聚丙烯酰胺层内,通过电聚合将纳米omip与金丝网印刷电极集成在一起。利用循环伏安法和电化学阻抗谱法对hcG传感器进行检测。两种电化学模式均适用于生物标志物选择性结合的测定。该传感器还使用非靶蛋白(SARS-CoV2核衣壳蛋白)进行了测试,结果表明,与非靶蛋白相比,该传感器对靶hCG的选择性高20倍。线性范围为1.5至384 mIU, LOD为3 mIU,饱和发生在1000 mIU以上。我们还通过电化学方法确定了EIS的平衡解离常数为1.4 x 10-10 M,与针对hCG生产的单克隆抗体相当。传感器可重用性研究表明,经过十二烷基硫酸钠/乙酸处理后,同一传感器一旦再生,可用于3次后续测量。我们提出了一种既可用于妊娠检测又可用于睾丸癌监测的有效方法。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analyst
Analyst 化学-分析化学
CiteScore
7.80
自引率
4.80%
发文量
636
审稿时长
1.9 months
期刊介绍: "Analyst" journal is the home of premier fundamental discoveries, inventions and applications in the analytical and bioanalytical sciences.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信