{"title":"Agreement between HRCT Imaging and Intraoperative Measurements in Predicting Stapedotomy Prosthesis Length in Otosclerosis Patients.","authors":"Mohamad Reza Afzalzadeh, Farzaneh Khoroushi, Abolfazl Zanjani Tabasi, Yazdan Gholami Chenaran, Mohsen Rajati, Hassan Mehrad-Majd","doi":"10.22038/ijorl.2025.81759.3749","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>This study aimed to evaluate the accuracy of preoperative high-resolution computed tomography (HRCT) imaging in measuring the distance from the long process of the incus to the footplate and its potential for predicting the optimal prosthesis length required for stapedotomy in patients with otosclerosis.</p><p><strong>Materials and methods: </strong>This cross-sectional study included fifty patients scheduled for primary stapedotomy. A radiologist obtained and reconstructed preoperative HRCT scans of the temporal bone to measure the distance from the long process of the incus to the oval window in both axial and coronal views. These HRCT-derived measurements were then compared with intraoperative measurements performed by an otolaryngologist. The agreement between the two methods was assessed using correlation and Bland-Altman analysis.</p><p><strong>Results: </strong>The mean distances measured by HRCT and intraoperatively were 4.15mm and 4.27mm, respectively. A strong and statistically significant correlation (r=0.928, P<0.001) was observed between the two approaches, indicating a robust association. The Bland-Altman analysis revealed a mean bias of 0.11±0.07mm, with limits of agreement (LoAs) ranging from -0.02 to 0.26 mm, and no points exceeding the 95% LoAs. The maximum potential error between the two measurement methods was 0.28mm, suggesting that HRCT imaging can reliably predict prosthesis length. In a stratified analysis based on the surgical distance (≤4 mm [N=11], 4.25mm [N=25], ≥4.5mm [N=13]), good agreement was maintained in the Bland-Altman analysis.</p><p><strong>Conclusion: </strong>Preoperative HRCT imaging may be a valuable tool for accurately predicting the required prosthesis length prior to stapedotomy in otosclerosis patients.</p>","PeriodicalId":14607,"journal":{"name":"Iranian Journal of Otorhinolaryngology","volume":"37 4","pages":"205-211"},"PeriodicalIF":0.0000,"publicationDate":"2025-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12335668/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Iranian Journal of Otorhinolaryngology","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.22038/ijorl.2025.81759.3749","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Introduction: This study aimed to evaluate the accuracy of preoperative high-resolution computed tomography (HRCT) imaging in measuring the distance from the long process of the incus to the footplate and its potential for predicting the optimal prosthesis length required for stapedotomy in patients with otosclerosis.

Materials and methods: This cross-sectional study included fifty patients scheduled for primary stapedotomy. A radiologist obtained and reconstructed preoperative HRCT scans of the temporal bone to measure the distance from the long process of the incus to the oval window in both axial and coronal views. These HRCT-derived measurements were then compared with intraoperative measurements performed by an otolaryngologist. The agreement between the two methods was assessed using correlation and Bland-Altman analysis.

Results: The mean distances measured by HRCT and intraoperatively were 4.15mm and 4.27mm, respectively. A strong and statistically significant correlation (r=0.928, P<0.001) was observed between the two approaches, indicating a robust association. The Bland-Altman analysis revealed a mean bias of 0.11±0.07mm, with limits of agreement (LoAs) ranging from -0.02 to 0.26 mm, and no points exceeding the 95% LoAs. The maximum potential error between the two measurement methods was 0.28mm, suggesting that HRCT imaging can reliably predict prosthesis length. In a stratified analysis based on the surgical distance (≤4 mm [N=11], 4.25mm [N=25], ≥4.5mm [N=13]), good agreement was maintained in the Bland-Altman analysis.

Conclusion: Preoperative HRCT imaging may be a valuable tool for accurately predicting the required prosthesis length prior to stapedotomy in otosclerosis patients.

HRCT成像与术中测量预测耳硬化患者镫骨切开术假体长度的一致性。
前言:本研究旨在评估术前高分辨率计算机断层扫描(HRCT)成像在测量从砧骨到足踏板的距离方面的准确性,以及它在预测耳硬化患者镫骨切除术所需的最佳假体长度方面的潜力。材料和方法:本横断面研究包括50例预定进行初级镫骨切除术的患者。放射科医生获得并重建术前颞骨HRCT扫描,以测量轴位和冠状位上从砧骨长突到卵圆窗的距离。然后将这些hrct测量结果与耳鼻喉科医生进行的术中测量结果进行比较。使用相关性和Bland-Altman分析来评估两种方法之间的一致性。结果:HRCT和术中测量的平均距离分别为4.15mm和4.27mm。结论:术前HRCT成像可能是耳硬化患者镫骨切除术前准确预测所需假体长度的有价值的工具。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Iranian Journal of Otorhinolaryngology
Iranian Journal of Otorhinolaryngology Medicine-Otorhinolaryngology
CiteScore
1.30
自引率
0.00%
发文量
72
审稿时长
12 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信