SCMR Expert Consensus Statement on Quantitative Myocardial Perfusion Cardiovascular Magnetic Resonance Imaging.

IF 6.1 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Amedeo Chiribiri, Andrew E Arai, Edward DiBella, Li-Yueh Hsu, Masaki Ishida, Michael Jerosch-Herold, Sebastian Kozerke, Xenios Milidonis, Reza Nezafat, Sven Plein, Cian M Scannell, Michael Salerno
{"title":"SCMR Expert Consensus Statement on Quantitative Myocardial Perfusion Cardiovascular Magnetic Resonance Imaging.","authors":"Amedeo Chiribiri, Andrew E Arai, Edward DiBella, Li-Yueh Hsu, Masaki Ishida, Michael Jerosch-Herold, Sebastian Kozerke, Xenios Milidonis, Reza Nezafat, Sven Plein, Cian M Scannell, Michael Salerno","doi":"10.1016/j.jocmr.2025.101940","DOIUrl":null,"url":null,"abstract":"<p><p>Myocardial perfusion imaging plays a central role in the management of patients with known or suspected coronary artery disease (CAD) and increasingly in patients with suspected ischemia with normal coronary arteries (INOCA) as well as anomalous origins of the coronary arteries and Kawasaki disease. Stress perfusion cardiovascular magnetic resonance (CMR) is recognized by international guidelines, with several Class 1 indications for the detection of abnormal myocardial blood flow in these clinical scenarios and offers excellent diagnostic accuracy and independent prognostic value. While visual interpretation of the perfusion data is the prevailing analysis method in clinical practice, quantitative perfusion CMR is at least as accurate for the detection of significant obstructive CAD and provides a more accurate estimation of the total ischemic burden in patients with CAD. Moreover, quantitative myocardial perfusion analysis provides unique insights into the pathophysiology of myocardial ischemia, including microvascular disease in INOCA. Quantitative perfusion CMR can be fully automated, is user-independent, and may facilitate more widespread use of the modality. The aim of this Society for Cardiovascular Magnetic Resonance (SCMR) expert consensus document is to provide recommendations for the acquisition and analysis of quantitative myocardial perfusion CMR to facilitate standardization of methodology. This paper also discusses research and development goals to address current limitations, to ensure data reliability and validity, to create the basis for future multi-vendor and multi-center research, and to broaden the clinical use of quantitative perfusion CMR.</p>","PeriodicalId":15221,"journal":{"name":"Journal of Cardiovascular Magnetic Resonance","volume":" ","pages":"101940"},"PeriodicalIF":6.1000,"publicationDate":"2025-08-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Cardiovascular Magnetic Resonance","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jocmr.2025.101940","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Myocardial perfusion imaging plays a central role in the management of patients with known or suspected coronary artery disease (CAD) and increasingly in patients with suspected ischemia with normal coronary arteries (INOCA) as well as anomalous origins of the coronary arteries and Kawasaki disease. Stress perfusion cardiovascular magnetic resonance (CMR) is recognized by international guidelines, with several Class 1 indications for the detection of abnormal myocardial blood flow in these clinical scenarios and offers excellent diagnostic accuracy and independent prognostic value. While visual interpretation of the perfusion data is the prevailing analysis method in clinical practice, quantitative perfusion CMR is at least as accurate for the detection of significant obstructive CAD and provides a more accurate estimation of the total ischemic burden in patients with CAD. Moreover, quantitative myocardial perfusion analysis provides unique insights into the pathophysiology of myocardial ischemia, including microvascular disease in INOCA. Quantitative perfusion CMR can be fully automated, is user-independent, and may facilitate more widespread use of the modality. The aim of this Society for Cardiovascular Magnetic Resonance (SCMR) expert consensus document is to provide recommendations for the acquisition and analysis of quantitative myocardial perfusion CMR to facilitate standardization of methodology. This paper also discusses research and development goals to address current limitations, to ensure data reliability and validity, to create the basis for future multi-vendor and multi-center research, and to broaden the clinical use of quantitative perfusion CMR.

定量心肌灌注心血管磁共振成像专家共识声明。
心肌灌注成像在已知或疑似冠状动脉疾病(CAD)患者的治疗中发挥着核心作用,在疑似正常冠状动脉缺血(INOCA)以及冠状动脉异常起源和川崎病的患者中也越来越重要。应激灌注心血管磁共振(CMR)被国际指南所认可,在这些临床情况下有几种1级适应症用于检测异常心肌血流,具有出色的诊断准确性和独立的预后价值。虽然灌注数据的可视化解释是临床实践中流行的分析方法,但定量灌注CMR至少在检测明显的阻塞性CAD方面同样准确,并且可以更准确地估计CAD患者的总缺血性负担。此外,定量心肌灌注分析提供了独特的见解心肌缺血的病理生理,包括微血管疾病在INOCA。定量灌注CMR可以完全自动化,与用户无关,并且可以促进更广泛的使用。本心血管磁共振学会(SCMR)专家共识文件的目的是为定量心肌灌注CMR的采集和分析提供建议,以促进方法的标准化。本文还讨论了研究和发展目标,以解决当前的局限性,确保数据的可靠性和有效性,为未来多供应商和多中心的研究奠定基础,并扩大定量灌注CMR的临床应用。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
10.90
自引率
12.50%
发文量
61
审稿时长
6-12 weeks
期刊介绍: Journal of Cardiovascular Magnetic Resonance (JCMR) publishes high-quality articles on all aspects of basic, translational and clinical research on the design, development, manufacture, and evaluation of cardiovascular magnetic resonance (CMR) methods applied to the cardiovascular system. Topical areas include, but are not limited to: New applications of magnetic resonance to improve the diagnostic strategies, risk stratification, characterization and management of diseases affecting the cardiovascular system. New methods to enhance or accelerate image acquisition and data analysis. Results of multicenter, or larger single-center studies that provide insight into the utility of CMR. Basic biological perceptions derived by CMR methods.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信