Eamonn Clarke, Spencer Sonntag, Carol Korzeniewski, Marc D Porter
{"title":"Analysis of Small Area Metal Surfaces Using Infrared External Reflection Spectroscopy.","authors":"Eamonn Clarke, Spencer Sonntag, Carol Korzeniewski, Marc D Porter","doi":"10.1177/00037028251370376","DOIUrl":null,"url":null,"abstract":"<p><p>This paper reports on the application of infrared external reflection spectroscopy (IR-ERS) to the characterization of small surface area addresses prepared on smooth gold surfaces after modification for use as capture substrates in sandwich immunoassays based on surface-enhanced Raman scattering (SERS). Most of the past work with IR-ERS on analyzing coatings formed on highly reflective metals utilized relatively large area samples (e.g., 76 × 25 mm glass microscope slides and ∼51 mm diameter silicon wafers) to accommodate the large size of the elliptical IR beam reflected off the metal surface at grazing angles of incidence. Our interest in employing assay-sized (3 mm diameter) addresses for IR-ERS measurements arises from the need to minimize the consumption, and, thereby, the expense of rare biological reagents like the antibodies under development for immunoassays to detect tuberculosis. The obvious approach to achieving this goal would be to utilize the spatial resolution and sample scanning capabilities of Fourier transform infrared (FT-IR) microscopes. We, however, opted to re-examine the physical optics and geometric layout of the measurement through an analysis of the strength of the mean square electric field at the sample/substrate interface as a function of angle of incidence. These findings suggested that, given the high light throughput and low noise levels of today's FT-IR spectrometers, it may be possible to perform these measurements simply by collecting spectra at a lower angle of incidence when using the optical layout of a standard IR-ERS experiment. Herein, we report both the theoretical analysis and experimental results that demonstrate it is possible to obtain useful spectra from much smaller samples than those traditionally used, e.g., those employed in our SERS-based immunoassays, simply by decreasing the angle at which the IR beam is incident on the sample surface. We also demonstrate that these types of samples can be analyzed by constructing a small jig that allows for the careful positioning of the sample in the IR beam, rather than by extensively modifying the optics of the IR-ERS accessory.</p>","PeriodicalId":8253,"journal":{"name":"Applied Spectroscopy","volume":" ","pages":"1429-1440"},"PeriodicalIF":2.2000,"publicationDate":"2025-09-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Applied Spectroscopy","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1177/00037028251370376","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/8 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"INSTRUMENTS & INSTRUMENTATION","Score":null,"Total":0}
引用次数: 0
Abstract
This paper reports on the application of infrared external reflection spectroscopy (IR-ERS) to the characterization of small surface area addresses prepared on smooth gold surfaces after modification for use as capture substrates in sandwich immunoassays based on surface-enhanced Raman scattering (SERS). Most of the past work with IR-ERS on analyzing coatings formed on highly reflective metals utilized relatively large area samples (e.g., 76 × 25 mm glass microscope slides and ∼51 mm diameter silicon wafers) to accommodate the large size of the elliptical IR beam reflected off the metal surface at grazing angles of incidence. Our interest in employing assay-sized (3 mm diameter) addresses for IR-ERS measurements arises from the need to minimize the consumption, and, thereby, the expense of rare biological reagents like the antibodies under development for immunoassays to detect tuberculosis. The obvious approach to achieving this goal would be to utilize the spatial resolution and sample scanning capabilities of Fourier transform infrared (FT-IR) microscopes. We, however, opted to re-examine the physical optics and geometric layout of the measurement through an analysis of the strength of the mean square electric field at the sample/substrate interface as a function of angle of incidence. These findings suggested that, given the high light throughput and low noise levels of today's FT-IR spectrometers, it may be possible to perform these measurements simply by collecting spectra at a lower angle of incidence when using the optical layout of a standard IR-ERS experiment. Herein, we report both the theoretical analysis and experimental results that demonstrate it is possible to obtain useful spectra from much smaller samples than those traditionally used, e.g., those employed in our SERS-based immunoassays, simply by decreasing the angle at which the IR beam is incident on the sample surface. We also demonstrate that these types of samples can be analyzed by constructing a small jig that allows for the careful positioning of the sample in the IR beam, rather than by extensively modifying the optics of the IR-ERS accessory.
期刊介绍:
Applied Spectroscopy is one of the world''s leading spectroscopy journals, publishing high-quality peer-reviewed articles, both fundamental and applied, covering all aspects of spectroscopy. Established in 1951, the journal is owned by the Society for Applied Spectroscopy and is published monthly. The journal is dedicated to fulfilling the mission of the Society to “…advance and disseminate knowledge and information concerning the art and science of spectroscopy and other allied sciences.”