General Purpose Deep Learning Attenuation Correction Improves Diagnostic Accuracy of SPECT MPI: A Multicenter Study.

IF 15.2 1区 医学 Q1 CARDIAC & CARDIOVASCULAR SYSTEMS
Aakash D Shanbhag,Robert J H Miller,Mark Lemley,Paul Kavanagh,Joanna X Liang,Anna M Marcinkiewicz,Valerie Builoff,Serge Van Kriekinge,Terrence D Ruddy,Mathews B Fish,Andrew J Einstein,Monica Martins,Julian P Halcox,Philipp A Kaufmann,Christopher Buckley,Timothy M Bateman,Daniel S Berman,Damini Dey,Piotr J Slomka
{"title":"General Purpose Deep Learning Attenuation Correction Improves Diagnostic Accuracy of SPECT MPI: A Multicenter Study.","authors":"Aakash D Shanbhag,Robert J H Miller,Mark Lemley,Paul Kavanagh,Joanna X Liang,Anna M Marcinkiewicz,Valerie Builoff,Serge Van Kriekinge,Terrence D Ruddy,Mathews B Fish,Andrew J Einstein,Monica Martins,Julian P Halcox,Philipp A Kaufmann,Christopher Buckley,Timothy M Bateman,Daniel S Berman,Damini Dey,Piotr J Slomka","doi":"10.1016/j.jcmg.2025.06.010","DOIUrl":null,"url":null,"abstract":"BACKGROUND\r\nSingle-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) uses computed tomography (CT)-based attenuation correction (AC) to improve diagnostic accuracy. Deep learning (DL) has the potential to generate synthetic AC images, as an alternative to CT-based AC.\r\n\r\nOBJECTIVES\r\nThis study evaluated whether DL-generated synthetic SPECT images could enhance accuracy of conventional SPECT MPI.\r\n\r\nMETHODS\r\nStudy investigators developed a DL model in a multicenter cohort of 4,894 patients from 4 sites to generate simulated SPECT AC images (DeepAC). The model was externally validated in 746 patients from 72 sites in a clinical trial (A Phase 3 Multicenter Study to Assess PET Imaging of Flurpiridaz F 18 Injection in Patients With CAD; NCT01347710) and in 320 patients from another external site. In the first external cohort, the study assessed the diagnostic accuracy for obstructive coronary artery disease (CAD)-defined as left main coronary artery stenosis ≥50% or ≥70% in other vessels-for total perfusion deficit (TPD). In the latter, the study completed change analysis and compared quantitative scores for AC, DeepAC, and nonattenuation correction (NC) with clinical scores.\r\n\r\nRESULTS\r\nIn the first external cohort (mean age, 63 ± 9.5 years; 69.0% male), 206 patients (27.6%) had obstructive CAD. The area under the receiver-operating characteristic curve (AUC) of DeepAC TPD (0.77; 95% CI: 0.73-0.81) was higher than the NC TPD (AUC: 0.73; 95% CI: 0.69-0.77; P < 0.001). In the second external cohort, DeepAC quantitative scores had closer agreement with actual AC scores compared with NC.\r\n\r\nCONCLUSIONS\r\nIn a multicenter external cohort, DeepAC improved prediction performance for obstructive CAD. This approach could enhance diagnostic accuracy in facilities using conventional SPECT systems without requiring additional equipment, imaging time, or radiation exposure.","PeriodicalId":14767,"journal":{"name":"JACC. Cardiovascular imaging","volume":"15 1","pages":""},"PeriodicalIF":15.2000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"JACC. Cardiovascular imaging","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1016/j.jcmg.2025.06.010","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

BACKGROUND Single-photon emission computed tomography (SPECT) myocardial perfusion imaging (MPI) uses computed tomography (CT)-based attenuation correction (AC) to improve diagnostic accuracy. Deep learning (DL) has the potential to generate synthetic AC images, as an alternative to CT-based AC. OBJECTIVES This study evaluated whether DL-generated synthetic SPECT images could enhance accuracy of conventional SPECT MPI. METHODS Study investigators developed a DL model in a multicenter cohort of 4,894 patients from 4 sites to generate simulated SPECT AC images (DeepAC). The model was externally validated in 746 patients from 72 sites in a clinical trial (A Phase 3 Multicenter Study to Assess PET Imaging of Flurpiridaz F 18 Injection in Patients With CAD; NCT01347710) and in 320 patients from another external site. In the first external cohort, the study assessed the diagnostic accuracy for obstructive coronary artery disease (CAD)-defined as left main coronary artery stenosis ≥50% or ≥70% in other vessels-for total perfusion deficit (TPD). In the latter, the study completed change analysis and compared quantitative scores for AC, DeepAC, and nonattenuation correction (NC) with clinical scores. RESULTS In the first external cohort (mean age, 63 ± 9.5 years; 69.0% male), 206 patients (27.6%) had obstructive CAD. The area under the receiver-operating characteristic curve (AUC) of DeepAC TPD (0.77; 95% CI: 0.73-0.81) was higher than the NC TPD (AUC: 0.73; 95% CI: 0.69-0.77; P < 0.001). In the second external cohort, DeepAC quantitative scores had closer agreement with actual AC scores compared with NC. CONCLUSIONS In a multicenter external cohort, DeepAC improved prediction performance for obstructive CAD. This approach could enhance diagnostic accuracy in facilities using conventional SPECT systems without requiring additional equipment, imaging time, or radiation exposure.
通用深度学习衰减校正提高SPECT MPI的诊断准确性:一项多中心研究。
背景:单光子发射计算机断层扫描(SPECT)心肌灌注成像(MPI)使用基于计算机断层扫描(CT)的衰减校正(AC)来提高诊断准确性。深度学习(Deep learning, DL)有可能生成合成的交流图像,作为基于ct的交流的替代方案。目的本研究评估DL生成的合成SPECT图像是否可以提高传统SPECT MPI的准确性。研究人员在来自4个地点的4,894名患者的多中心队列中开发了DL模型,以生成模拟SPECT AC图像(DeepAC)。在一项临床试验中,来自72个地点的746名患者对该模型进行了外部验证(一项评估氟吡达f18注射液在CAD患者中的PET成像的3期多中心研究;NCT01347710)和320例来自其他外部部位的患者。在第一个外部队列中,该研究评估了阻塞性冠状动脉疾病(CAD)的诊断准确性(定义为左主干冠状动脉狭窄≥50%或其他血管≥70%),用于总灌注缺陷(TPD)。在后者中,研究完成了变化分析,并将AC、DeepAC和非衰减校正(NC)的定量评分与临床评分进行了比较。结果第一个外部队列(平均年龄63±9.5岁;男性69.0%),梗阻性CAD 206例(27.6%)。DeepAC TPD的受者-工作特征曲线下面积(AUC)为0.77;95% CI: 0.73-0.81)高于NC TPD (AUC: 0.73;95% ci: 0.69-0.77;P < 0.001)。在第二个外部队列中,与NC相比,DeepAC定量评分与实际AC评分更接近。结论在一个多中心外部队列中,DeepAC提高了对阻塞性CAD的预测性能。这种方法可以提高使用传统SPECT系统的设施的诊断准确性,而不需要额外的设备、成像时间或辐射暴露。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
JACC. Cardiovascular imaging
JACC. Cardiovascular imaging CARDIAC & CARDIOVASCULAR SYSTEMS-RADIOLOGY, NUCLEAR MEDICINE & MEDICAL IMAGING
CiteScore
24.90
自引率
5.70%
发文量
330
审稿时长
4-8 weeks
期刊介绍: JACC: Cardiovascular Imaging, part of the prestigious Journal of the American College of Cardiology (JACC) family, offers readers a comprehensive perspective on all aspects of cardiovascular imaging. This specialist journal covers original clinical research on both non-invasive and invasive imaging techniques, including echocardiography, CT, CMR, nuclear, optical imaging, and cine-angiography. JACC. Cardiovascular imaging highlights advances in basic science and molecular imaging that are expected to significantly impact clinical practice in the next decade. This influence encompasses improvements in diagnostic performance, enhanced understanding of the pathogenetic basis of diseases, and advancements in therapy. In addition to cutting-edge research,the content of JACC: Cardiovascular Imaging emphasizes practical aspects for the practicing cardiologist, including advocacy and practice management.The journal also features state-of-the-art reviews, ensuring a well-rounded and insightful resource for professionals in the field of cardiovascular imaging.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信