{"title":"Comparison of consistency between wireless and conventional wired monitoring systems in gastrointestinal endoscopy.","authors":"Peng Zhang, Jing Zhuang, Ting Li, Dan Fan, Qian Lei, Dayong Lin","doi":"10.1038/s41598-025-12927-2","DOIUrl":null,"url":null,"abstract":"<p><p>There is a lack of research on use and effectiveness of wearable monitoring devices in the setting of invasive procedures, such as gastrointestinal endoscopy. Our study aimed to compare the consistency between wireless and conventional wired monitoring systems in gastrointestinal endoscopy under sedation. One hundred and twenty patients undergoing gastrointestinal endoscopy with sedation/anesthesia were fitted with both wireless and conventional wired monitoring systems. Multiple physiological parameters, including heart rate (HR), pulse rate, peripheral oxygen saturation (SpO<sub>2</sub>) and systolic (SBP), diastolic (DBP) and mean blood pressure (MAP), were monitored and recorded simultaneously. The correlation coefficients were 0.999, 0.939, 0.606, 0.837, 0.934 and 0.941 for HR, pulse rate, SpO<sub>2</sub>, SBP, DBP and MAP, respectively (all p < 0.001). The HR exceeded its limits of agreements (LoAs) and clinically acceptable consistency thresholds in 56 (4.17%) and 41 (3.05%) data, pulse rate in 84 (6.0%) and 137 (9.80%) data, SpO<sub>2</sub> in 116 (8.30%) and 18 (1.28%) data, SBP in 39 (6.32%) and 121 (19.61%)data, DBP in 34 (5.34%) and 52 (8.43%) data, and MAP in 28 (4.54%) and 57 (9.24%) data. The polar concordance rate at 30 degrees was 59.31% for SBP, 61.12% for DBP, and 68.55% for MAP according to polar plot trending analysis. This study demonstrated that the wireless monitoring system showed adequate agreement with wired system for HR and SpO₂, but suboptimal agreement for pulse rate, SBP, DBP, and MAP during gastrointestinal endoscopy. The blood pressure measurements meets the ISO 81060-2 accuracy criteria. Overall, wireless monitoring is generally acceptable for gastrointestinal endoscopy, but further validation is needed for high-risk patients.</p>","PeriodicalId":21811,"journal":{"name":"Scientific Reports","volume":"15 1","pages":"28296"},"PeriodicalIF":3.9000,"publicationDate":"2025-08-03","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12319100/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Scientific Reports","FirstCategoryId":"103","ListUrlMain":"https://doi.org/10.1038/s41598-025-12927-2","RegionNum":2,"RegionCategory":"综合性期刊","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"MULTIDISCIPLINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
There is a lack of research on use and effectiveness of wearable monitoring devices in the setting of invasive procedures, such as gastrointestinal endoscopy. Our study aimed to compare the consistency between wireless and conventional wired monitoring systems in gastrointestinal endoscopy under sedation. One hundred and twenty patients undergoing gastrointestinal endoscopy with sedation/anesthesia were fitted with both wireless and conventional wired monitoring systems. Multiple physiological parameters, including heart rate (HR), pulse rate, peripheral oxygen saturation (SpO2) and systolic (SBP), diastolic (DBP) and mean blood pressure (MAP), were monitored and recorded simultaneously. The correlation coefficients were 0.999, 0.939, 0.606, 0.837, 0.934 and 0.941 for HR, pulse rate, SpO2, SBP, DBP and MAP, respectively (all p < 0.001). The HR exceeded its limits of agreements (LoAs) and clinically acceptable consistency thresholds in 56 (4.17%) and 41 (3.05%) data, pulse rate in 84 (6.0%) and 137 (9.80%) data, SpO2 in 116 (8.30%) and 18 (1.28%) data, SBP in 39 (6.32%) and 121 (19.61%)data, DBP in 34 (5.34%) and 52 (8.43%) data, and MAP in 28 (4.54%) and 57 (9.24%) data. The polar concordance rate at 30 degrees was 59.31% for SBP, 61.12% for DBP, and 68.55% for MAP according to polar plot trending analysis. This study demonstrated that the wireless monitoring system showed adequate agreement with wired system for HR and SpO₂, but suboptimal agreement for pulse rate, SBP, DBP, and MAP during gastrointestinal endoscopy. The blood pressure measurements meets the ISO 81060-2 accuracy criteria. Overall, wireless monitoring is generally acceptable for gastrointestinal endoscopy, but further validation is needed for high-risk patients.
期刊介绍:
We publish original research from all areas of the natural sciences, psychology, medicine and engineering. You can learn more about what we publish by browsing our specific scientific subject areas below or explore Scientific Reports by browsing all articles and collections.
Scientific Reports has a 2-year impact factor: 4.380 (2021), and is the 6th most-cited journal in the world, with more than 540,000 citations in 2020 (Clarivate Analytics, 2021).
•Engineering
Engineering covers all aspects of engineering, technology, and applied science. It plays a crucial role in the development of technologies to address some of the world''s biggest challenges, helping to save lives and improve the way we live.
•Physical sciences
Physical sciences are those academic disciplines that aim to uncover the underlying laws of nature — often written in the language of mathematics. It is a collective term for areas of study including astronomy, chemistry, materials science and physics.
•Earth and environmental sciences
Earth and environmental sciences cover all aspects of Earth and planetary science and broadly encompass solid Earth processes, surface and atmospheric dynamics, Earth system history, climate and climate change, marine and freshwater systems, and ecology. It also considers the interactions between humans and these systems.
•Biological sciences
Biological sciences encompass all the divisions of natural sciences examining various aspects of vital processes. The concept includes anatomy, physiology, cell biology, biochemistry and biophysics, and covers all organisms from microorganisms, animals to plants.
•Health sciences
The health sciences study health, disease and healthcare. This field of study aims to develop knowledge, interventions and technology for use in healthcare to improve the treatment of patients.