Evaluation of femoral isometric placement accuracy of internal brace implants and its impact on stifle stability in the management of pivot shift phenomenon following TPLO.

IF 1.3 2区 农林科学 Q2 VETERINARY SCIENCES
Veterinary Surgery Pub Date : 2025-10-01 Epub Date: 2025-08-01 DOI:10.1111/vsu.14319
Sebastian Wylie, Miguel A Solano, Alan Danielski
{"title":"Evaluation of femoral isometric placement accuracy of internal brace implants and its impact on stifle stability in the management of pivot shift phenomenon following TPLO.","authors":"Sebastian Wylie, Miguel A Solano, Alan Danielski","doi":"10.1111/vsu.14319","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To evaluate the impact of accurate isometric placement of internal brace implants on stifle stability following tibial plateau leveling osteotomy (TPLO) in dogs with pivot shift phenomenon and to propose a novel classification system for pivot shift grading.</p><p><strong>Study design: </strong>Retrospective observational study.</p><p><strong>Animals: </strong>A total of 39 dogs (46 stifles) undergoing TPLO with internal brace augmentation using SwiveLock and FASTak implants.</p><p><strong>Methods: </strong>Medical records, intraoperative assessments, and radiographs were reviewed. Femoral implant positioning was classified as accurate or inaccurate. Pivot shift was graded pre-, intraoperatively, and at 6-week follow-up using a simplified two-grade system. Learning curves for implant accuracy were compared between implant types. Statistical analyses included χ<sup>2</sup> and t-tests, with significance set at p < .05.</p><p><strong>Results: </strong>Accurate implant positioning was achieved in 29 of 46 stifles (63.0%). SwiveLock implants were significantly more likely to be accurately placed than FASTak anchors (p = .016), with higher patient weight correlating with improved accuracy (p = .012). SwiveLock implants reached an accuracy rate of 78.6% compared to 38.9% for FASTak (p = .014). At follow-up, mean pivot shift grade improved in 90.9% of stifles (p < .001). Inaccurate implant positioning was significantly associated with increased internal tibial rotation (p = .009) but not with the pivot shift grade (p = .142).</p><p><strong>Conclusion: </strong>Accurate isometric placement of internal brace implants is critical for optimizing stifle stability and addressing pivot shift following TPLO.</p><p><strong>Clinical significance: </strong>Enhanced implant accuracy and a standardized pivot shift classification may improve surgical outcomes and guide postoperative management in dogs.</p>","PeriodicalId":23667,"journal":{"name":"Veterinary Surgery","volume":" ","pages":"1316-1325"},"PeriodicalIF":1.3000,"publicationDate":"2025-10-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Veterinary Surgery","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.1111/vsu.14319","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/8/1 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To evaluate the impact of accurate isometric placement of internal brace implants on stifle stability following tibial plateau leveling osteotomy (TPLO) in dogs with pivot shift phenomenon and to propose a novel classification system for pivot shift grading.

Study design: Retrospective observational study.

Animals: A total of 39 dogs (46 stifles) undergoing TPLO with internal brace augmentation using SwiveLock and FASTak implants.

Methods: Medical records, intraoperative assessments, and radiographs were reviewed. Femoral implant positioning was classified as accurate or inaccurate. Pivot shift was graded pre-, intraoperatively, and at 6-week follow-up using a simplified two-grade system. Learning curves for implant accuracy were compared between implant types. Statistical analyses included χ2 and t-tests, with significance set at p < .05.

Results: Accurate implant positioning was achieved in 29 of 46 stifles (63.0%). SwiveLock implants were significantly more likely to be accurately placed than FASTak anchors (p = .016), with higher patient weight correlating with improved accuracy (p = .012). SwiveLock implants reached an accuracy rate of 78.6% compared to 38.9% for FASTak (p = .014). At follow-up, mean pivot shift grade improved in 90.9% of stifles (p < .001). Inaccurate implant positioning was significantly associated with increased internal tibial rotation (p = .009) but not with the pivot shift grade (p = .142).

Conclusion: Accurate isometric placement of internal brace implants is critical for optimizing stifle stability and addressing pivot shift following TPLO.

Clinical significance: Enhanced implant accuracy and a standardized pivot shift classification may improve surgical outcomes and guide postoperative management in dogs.

评估内支架植入物股骨等距放置精度及其对TPLO后椎枢移位现象处理中膝关节稳定性的影响。
目的:评价胫骨平台水平截骨术(TPLO)后准确等距放置内支对膝关节稳定性的影响,并提出一种新的支点移位分级体系。研究设计:回顾性观察性研究。动物:共有39只狗(46只)使用SwiveLock和FASTak植入物进行TPLO和内支架增强。方法:回顾医疗记录、术中评估和x线片。股骨植入物定位分为准确和不准确。枢轴移位在术前、术中和6周随访时采用简化的两级系统进行分级。比较不同种植体类型种植体准确度的学习曲线。统计分析采用χ2和t检验,显著性设置为p。结果:46个假体中有29个(63.0%)的假体定位准确。SwiveLock种植体明显比FASTak锚更容易准确放置(p = 0.016),患者体重增加与准确性提高相关(p = 0.012)。SwiveLock植入物的准确率为78.6%,FASTak为38.9% (p = 0.014)。在随访中,90.9%的患者的平均支点移位等级得到改善(p)。结论:准确的内支植入物等距放置对于优化TPLO术后膝关节稳定性和解决支点移位问题至关重要。临床意义:提高植入物的准确性和标准化的支点移位分类可以改善狗的手术效果和指导术后管理。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Veterinary Surgery
Veterinary Surgery 农林科学-兽医学
CiteScore
3.40
自引率
22.20%
发文量
162
审稿时长
8-16 weeks
期刊介绍: Veterinary Surgery, the official publication of the American College of Veterinary Surgeons and European College of Veterinary Surgeons, is a source of up-to-date coverage of surgical and anesthetic management of animals, addressing significant problems in veterinary surgery with relevant case histories and observations. It contains original, peer-reviewed articles that cover developments in veterinary surgery, and presents the most current review of the field, with timely articles on surgical techniques, diagnostic aims, care of infections, and advances in knowledge of metabolism as it affects the surgical patient. The journal places new developments in perspective, encompassing new concepts and peer commentary to help better understand and evaluate the surgical patient.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信