{"title":"Breakdown Characteristics of Transformer Liquids With Winding Conductor Segments Under Lightning Impulse","authors":"Haichuan Yu;Qiang Liu;Zhongdong Wang;Christoph Krause;Mark Wilkinson","doi":"10.1109/TDEI.2025.3530905","DOIUrl":null,"url":null,"abstract":"Historically, transformer insulation design is based on experience with mineral oil (MO). The basic insulation level (BIL) determines the lightning impulse withstand level (LIWL) for a specific design. These design values are not necessarily appliable to other insulating liquids than MO. There are few published studies on BIL using nonmineral-based liquids in design-relevant insulation geometries. The present study compares lightning impulse (LI) breakdown voltages (BDVs) of a synthetic ester (SE) liquid and a gas-to-liquid (GTL) oil with those of MO using winding conductors as electrode geometries. The field enhancement factors for the bare electrodes are below 4.1 in all cases indicating the quasi-uniform fields. The effects of liquid gap distance, paper wrapping, and impulse polarity are all considered. It is found that the LI BDVs of the alternative transformer liquids are comparable to those of the MO. The streamer propagation characteristics during the breakdown process are also captured. The results show that the breakdowns are led by the fast streamer under positive LI, and there is a streamer mode transition under negative LI. The BDVs are found to be practically the same for both polarities, and they barely differ among the three investigated transformer liquids. This is because the breakdowns are dominated by the streamer initiation under the present test electrode geometries and conditions.","PeriodicalId":13247,"journal":{"name":"IEEE Transactions on Dielectrics and Electrical Insulation","volume":"32 4","pages":"2099-2107"},"PeriodicalIF":3.1000,"publicationDate":"2025-01-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"IEEE Transactions on Dielectrics and Electrical Insulation","FirstCategoryId":"5","ListUrlMain":"https://ieeexplore.ieee.org/document/10843785/","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"ENGINEERING, ELECTRICAL & ELECTRONIC","Score":null,"Total":0}
引用次数: 0

Abstract

Historically, transformer insulation design is based on experience with mineral oil (MO). The basic insulation level (BIL) determines the lightning impulse withstand level (LIWL) for a specific design. These design values are not necessarily appliable to other insulating liquids than MO. There are few published studies on BIL using nonmineral-based liquids in design-relevant insulation geometries. The present study compares lightning impulse (LI) breakdown voltages (BDVs) of a synthetic ester (SE) liquid and a gas-to-liquid (GTL) oil with those of MO using winding conductors as electrode geometries. The field enhancement factors for the bare electrodes are below 4.1 in all cases indicating the quasi-uniform fields. The effects of liquid gap distance, paper wrapping, and impulse polarity are all considered. It is found that the LI BDVs of the alternative transformer liquids are comparable to those of the MO. The streamer propagation characteristics during the breakdown process are also captured. The results show that the breakdowns are led by the fast streamer under positive LI, and there is a streamer mode transition under negative LI. The BDVs are found to be practically the same for both polarities, and they barely differ among the three investigated transformer liquids. This is because the breakdowns are dominated by the streamer initiation under the present test electrode geometries and conditions.
带绕组导体段的变压器液体在雷击下的击穿特性
从历史上看,变压器绝缘设计是基于矿物油(MO)的经验。基本绝缘等级(BIL)决定了特定设计的耐雷击等级(LIWL)。这些设计值不一定适用于MO以外的其他绝缘液体。在设计相关绝缘几何形状时使用非矿物基液体的BIL的已发表研究很少。本研究比较了合成酯(SE)液体和气转液(GTL)油的雷击击穿电压(BDVs)与使用绕组导体作为电极几何形状的MO的雷击击穿电压(BDVs)。在所有情况下,裸电极的场增强系数都小于4.1,表明具有准均匀场。考虑了液体间隙距离、纸张包裹和脉冲极性的影响。研究发现,交替变压器液体的LI bdv与MO相当,并捕获了击穿过程中的流光传播特性。结果表明,在正LI条件下,击穿是由快速流光引起的,而在负LI条件下,则存在流光模式的转变。bdv被发现几乎是相同的极性,他们几乎不同的三个研究变压器液体。这是因为在目前的测试电极几何形状和条件下,击穿主要是由流光引发的。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
IEEE Transactions on Dielectrics and Electrical Insulation
IEEE Transactions on Dielectrics and Electrical Insulation 工程技术-工程:电子与电气
CiteScore
6.00
自引率
22.60%
发文量
309
审稿时长
5.2 months
期刊介绍: Topics that are concerned with dielectric phenomena and measurements, with development and characterization of gaseous, vacuum, liquid and solid electrical insulating materials and systems; and with utilization of these materials in circuits and systems under condition of use.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信