{"title":"Effectiveness of continuous glucose monitoring systems on glycemic control in adults with type 1 diabetes: A systematic review and meta-analysis","authors":"Salya F. Alfadli , Yazeed S. Alotaibi , Maha J. Aqdi , Latifah A. Almozan , Zahra B. Alzubaidi , Hammad A. Altemani , Shaden D. Almutairi , Hussain A. Alabdullah , Alaa Ahmed Almehmadi , Abdulrahman L. Alanzi , Ahmed Y. Azzam","doi":"10.1016/j.metop.2025.100382","DOIUrl":null,"url":null,"abstract":"<div><h3>Introduction</h3><div>Continuous glucose monitoring (CGM) technologies have been advancing rapidly, but evidence on their comparative effectiveness stills limited to date yet. We conducted a systematic review and meta-analysis to evaluate and investigate the impact of CGM systems on glycemic control in adults with type 1 diabetes.</div></div><div><h3>Methods</h3><div>We searched electronic literature databases from inception through April 30, 2025, for comparative studies investigating CGM systems with standard monitoring or different CGM technologies in adults with type 1 diabetes. Primary outcomes included HbA1c reduction, time in range (TIR), and hypoglycemia reduction. We performed random-effects meta-analyses, network meta-analysis, and subgroup analyses by baseline HbA1c and intervention duration. Evidence quality was assessed using GRADE methodology.</div></div><div><h3>Results</h3><div>Twenty-seven studies with total of 2975 participants were included. CGM significantly reduced HbA1c compared to standard monitoring (mean difference: 0.38 %, 95 % CI: 0.49 to −0.27 %). TIR increased by 7.9 % (95 % CI: 5.8–10.0 %), representing 114 additional minutes daily in best range. Real-time CGM showed advantages over intermittently scanned CGM for TIR (+5.63 %, P-value<0.001) and hypoglycemia reduction (−1.28 %, P-value<0.001). Automated closed-loop systems achieved the highest ranking in network meta-analysis (SUCRA = 0.92). Benefits were greater among patients with higher baseline HbA1c (>8.5 %: 0.68 % reduction in HbA1c vs. <7.5 %: 0.24 % reduction in HbA1c, P-value = 0.009).</div></div><div><h3>Conclusions</h3><div>CGM technologies significantly improve glycemic control in adults with type 1 diabetes, with greater benefits for those with higher baseline HbA1c. Advanced systems demonstrate progressively greater improvements, with automated closed-loop systems showing the strongest evidence of effectiveness. These findings support broader implementation of CGM technologies, with selection tailored to individual patient needs.</div></div>","PeriodicalId":94141,"journal":{"name":"Metabolism open","volume":"27 ","pages":"Article 100382"},"PeriodicalIF":2.7000,"publicationDate":"2025-07-29","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Metabolism open","FirstCategoryId":"1085","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S2589936825000386","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction
Continuous glucose monitoring (CGM) technologies have been advancing rapidly, but evidence on their comparative effectiveness stills limited to date yet. We conducted a systematic review and meta-analysis to evaluate and investigate the impact of CGM systems on glycemic control in adults with type 1 diabetes.
Methods
We searched electronic literature databases from inception through April 30, 2025, for comparative studies investigating CGM systems with standard monitoring or different CGM technologies in adults with type 1 diabetes. Primary outcomes included HbA1c reduction, time in range (TIR), and hypoglycemia reduction. We performed random-effects meta-analyses, network meta-analysis, and subgroup analyses by baseline HbA1c and intervention duration. Evidence quality was assessed using GRADE methodology.
Results
Twenty-seven studies with total of 2975 participants were included. CGM significantly reduced HbA1c compared to standard monitoring (mean difference: 0.38 %, 95 % CI: 0.49 to −0.27 %). TIR increased by 7.9 % (95 % CI: 5.8–10.0 %), representing 114 additional minutes daily in best range. Real-time CGM showed advantages over intermittently scanned CGM for TIR (+5.63 %, P-value<0.001) and hypoglycemia reduction (−1.28 %, P-value<0.001). Automated closed-loop systems achieved the highest ranking in network meta-analysis (SUCRA = 0.92). Benefits were greater among patients with higher baseline HbA1c (>8.5 %: 0.68 % reduction in HbA1c vs. <7.5 %: 0.24 % reduction in HbA1c, P-value = 0.009).
Conclusions
CGM technologies significantly improve glycemic control in adults with type 1 diabetes, with greater benefits for those with higher baseline HbA1c. Advanced systems demonstrate progressively greater improvements, with automated closed-loop systems showing the strongest evidence of effectiveness. These findings support broader implementation of CGM technologies, with selection tailored to individual patient needs.