Minimally Invasive and in Situ Capacitive Sensing of Cardiac Troponin I from Interstitial Fluid.

IF 9.1 1区 化学 Q1 CHEMISTRY, ANALYTICAL
Hadi Mirzajani, Parviz Zolfaghari, Beril Yagmur Koca, Hakan Urey
{"title":"Minimally Invasive and in Situ Capacitive Sensing of Cardiac Troponin I from Interstitial Fluid.","authors":"Hadi Mirzajani, Parviz Zolfaghari, Beril Yagmur Koca, Hakan Urey","doi":"10.1021/acssensors.5c01691","DOIUrl":null,"url":null,"abstract":"<p><p>Current diagnostic approaches for myocardial infarction (MI) rely on blood-based cardiac biomarker analysis by centralized instruments, often delaying timely clinical decisions. We present a microneedle-based capacitive biosensor (MiCaP) for in situ minimally invasive monitoring of cardiac troponin I (cTnI) in interstitial fluid (ISF) for point-of-care (POC) applications. MiCaP is a label-free biosensor operating based on nonfaradaic sensing by monitoring electric double layer capacitance at the microneedle-ISF interface. We extracted a simplified equivalent circuit model for MiCaP inserted into the skin, confirming that the measured capacitance variations originate from cTnI binding to surface-immobilized antibodies. MiCaP was fabricated by using a scalable process and functionalized with anti-cTnI antibodies. In vitro measurements showed a dynamic detection range of 10 pg/mL to 10 ng/mL, a limit of detection (LOD) of 3.27 pg/mL, and a total assay response time of less than 15 min. A spike-and-recovery test using cTnI-spiked human serum yielded a recovery accuracy exceeding 93%. In vivo studies in rats demonstrated ISF cTnI levels of 3 ± 0.4 pg/mL in controls and 912 ± 683 pg/mL in experimental animals, indicating an increasing trend consistent with serum concentrations measured using a clinical immunoassay. These results support the potential of MiCaP as a minimally invasive biosensing platform for cardiac biomarker monitoring, with possible extension to multiplexed ISF-based diagnostics in the POC.</p>","PeriodicalId":24,"journal":{"name":"ACS Sensors","volume":" ","pages":""},"PeriodicalIF":9.1000,"publicationDate":"2025-07-27","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"ACS Sensors","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1021/acssensors.5c01691","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Current diagnostic approaches for myocardial infarction (MI) rely on blood-based cardiac biomarker analysis by centralized instruments, often delaying timely clinical decisions. We present a microneedle-based capacitive biosensor (MiCaP) for in situ minimally invasive monitoring of cardiac troponin I (cTnI) in interstitial fluid (ISF) for point-of-care (POC) applications. MiCaP is a label-free biosensor operating based on nonfaradaic sensing by monitoring electric double layer capacitance at the microneedle-ISF interface. We extracted a simplified equivalent circuit model for MiCaP inserted into the skin, confirming that the measured capacitance variations originate from cTnI binding to surface-immobilized antibodies. MiCaP was fabricated by using a scalable process and functionalized with anti-cTnI antibodies. In vitro measurements showed a dynamic detection range of 10 pg/mL to 10 ng/mL, a limit of detection (LOD) of 3.27 pg/mL, and a total assay response time of less than 15 min. A spike-and-recovery test using cTnI-spiked human serum yielded a recovery accuracy exceeding 93%. In vivo studies in rats demonstrated ISF cTnI levels of 3 ± 0.4 pg/mL in controls and 912 ± 683 pg/mL in experimental animals, indicating an increasing trend consistent with serum concentrations measured using a clinical immunoassay. These results support the potential of MiCaP as a minimally invasive biosensing platform for cardiac biomarker monitoring, with possible extension to multiplexed ISF-based diagnostics in the POC.

心肌间质液肌钙蛋白I的微创原位电容传感。
目前心肌梗死(MI)的诊断方法依赖于基于血液的心脏生物标志物分析,这往往会延迟及时的临床决策。我们提出了一种基于微针的电容式生物传感器(MiCaP),用于原位微创监测间质液(ISF)中的心肌肌钙蛋白I (cTnI),用于即时护理(POC)应用。MiCaP是一种无标签生物传感器,通过监测微针- isf界面的双电层电容,实现非法拉第传感。我们提取了插入皮肤的MiCaP的简化等效电路模型,证实了测量到的电容变化源于cTnI与表面固定抗体的结合。MiCaP采用可扩展工艺制备,并使用抗ctni抗体功能化。体外测定显示,动态检测范围为10 pg/mL至10 ng/mL,检出限(LOD)为3.27 pg/mL,总测定响应时间小于15 min。使用ctni加标的人血清进行的加标回收率试验,回收率超过93%。大鼠体内研究表明,对照组ISF cTnI水平为3±0.4 pg/mL,实验动物为912±683 pg/mL,与临床免疫测定法测得的血清浓度一致。这些结果支持MiCaP作为心脏生物标志物监测的微创生物传感平台的潜力,并可能扩展到POC中基于isf的多路诊断。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
ACS Sensors
ACS Sensors Chemical Engineering-Bioengineering
CiteScore
14.50
自引率
3.40%
发文量
372
期刊介绍: ACS Sensors is a peer-reviewed research journal that focuses on the dissemination of new and original knowledge in the field of sensor science, particularly those that selectively sense chemical or biological species or processes. The journal covers a broad range of topics, including but not limited to biosensors, chemical sensors, gas sensors, intracellular sensors, single molecule sensors, cell chips, and microfluidic devices. It aims to publish articles that address conceptual advances in sensing technology applicable to various types of analytes or application papers that report on the use of existing sensing concepts in new ways or for new analytes.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信