Reliability of a Linear Position Transducer During the Bench Press Across Three Segments.

Q1 Health Professions
International journal of exercise science Pub Date : 2025-06-01 eCollection Date: 2025-01-01 DOI:10.70252/OQIM2082
Jennifer Rivera, Edward Z Pelka, Ryan W Gant, Anthony G Pinzone, Emily C Tagesen, Modesto A Lebron, Adam R Jajtner
{"title":"Reliability of a Linear Position Transducer During the Bench Press Across Three Segments.","authors":"Jennifer Rivera, Edward Z Pelka, Ryan W Gant, Anthony G Pinzone, Emily C Tagesen, Modesto A Lebron, Adam R Jajtner","doi":"10.70252/OQIM2082","DOIUrl":null,"url":null,"abstract":"<p><p>The purpose of this investigation was to determine inter-set and inter-session reliability of the HUMAC360 measures for duration (DUR), peak velocity (PV) and mean velocity (MV) across three segments of the bench press. Seventeen recreationally active adults participated in this investigation. During visit one, participants completed a bench press one-repetition maximum (1RM). Visits two and three consisted of two sets of three repetitions at 30%-, 50%-, 60%-, and 70 %-1RM. Segments were defined by dividing total displacement into equal thirds at the bottom (BOT), middle (MID) and top (TOP). Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were used to assess reliability while paired samples t-tests were used to identify differences between sets or sessions with significance set at <i>p≤0.05</i>. Excellent ICCs were present for PV and MV at most intensities in each segment between sets, while ICCs for DUR varied. MV and PV displayed excellent ICCs at lower intensities across segments between sessions, with decreases at higher intensities, while variable inter- session reliability for DUR was present across intensities and segments. The HUMAC360 reliably measured MV and PV during each segment across sets, though caution is warranted for DUR.</p>","PeriodicalId":14171,"journal":{"name":"International journal of exercise science","volume":"18 2","pages":"622-635"},"PeriodicalIF":0.0000,"publicationDate":"2025-06-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12289235/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"International journal of exercise science","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.70252/OQIM2082","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"Health Professions","Score":null,"Total":0}
引用次数: 0

Abstract

The purpose of this investigation was to determine inter-set and inter-session reliability of the HUMAC360 measures for duration (DUR), peak velocity (PV) and mean velocity (MV) across three segments of the bench press. Seventeen recreationally active adults participated in this investigation. During visit one, participants completed a bench press one-repetition maximum (1RM). Visits two and three consisted of two sets of three repetitions at 30%-, 50%-, 60%-, and 70 %-1RM. Segments were defined by dividing total displacement into equal thirds at the bottom (BOT), middle (MID) and top (TOP). Intraclass correlation coefficients (ICC) and standard error of measurement (SEM) were used to assess reliability while paired samples t-tests were used to identify differences between sets or sessions with significance set at p≤0.05. Excellent ICCs were present for PV and MV at most intensities in each segment between sets, while ICCs for DUR varied. MV and PV displayed excellent ICCs at lower intensities across segments between sessions, with decreases at higher intensities, while variable inter- session reliability for DUR was present across intensities and segments. The HUMAC360 reliably measured MV and PV during each segment across sets, though caution is warranted for DUR.

Abstract Image

直线位置传感器在台式压力机跨三段过程中的可靠性。
本研究的目的是确定HUMAC360在台式压力机三个部分的持续时间(DUR)、峰值速度(PV)和平均速度(MV)测量的组间和组间可靠性。17名从事娱乐活动的成年人参加了这项调查。在第一次访问期间,参与者完成了一次最大重复卧推(1RM)。访问2和3包括两组三次重复,分别为30%,50%,60%和70% - 1rm。通过将总位移在底部(BOT)、中间(MID)和顶部(top)等分三分之来定义段。采用类内相关系数(ICC)和计量标准误差(SEM)来评估信度,采用配对样本t检验来识别组或会话之间的差异,显著性集p≤0.05。PV和MV的ICCs在组间各节段的大多数强度上都表现优异,而DUR的ICCs则有所不同。MV和PV在低强度下表现出良好的ICCs,在高强度下有所下降,而DUR的会话间可靠性在不同强度和段之间存在差异。HUMAC360可靠地测量了各组间每段的MV和PV,但需要注意DUR。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
International journal of exercise science
International journal of exercise science Health Professions-Occupational Therapy
CiteScore
2.20
自引率
0.00%
发文量
47
审稿时长
26 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信