Erik Brynskog, Jonas Östh, Karl-Johan Larsson, Johan Iraeus
{"title":"Effect of occupant and restraint variability in reclined positions on submarining probability in frontal car crash scenarios.","authors":"Erik Brynskog, Jonas Östh, Karl-Johan Larsson, Johan Iraeus","doi":"10.3389/fbioe.2025.1570572","DOIUrl":null,"url":null,"abstract":"<p><strong>Introduction: </strong>In future autonomous vehicles, a greater seat back recline angle has been suggested to accommodate a more relaxed occupant position. Due to the reclined position, the pelvis rotates rearward resulting in less favorable in-crash pelvis to lap belt interaction. In a crash, this issue can increase the likelihood of the lap belt disengaging from the pelvis and instead loading the abdomen, <i>i.e.</i>, submarining. Hence, to enable assessment of submarining prevention measures for reclined occupants in frontal car crash scenarios, it is motivated to enhance the understanding of pelvis to lap belt interaction.</p><p><strong>Method: </strong>In this simulation study, the submarining outcome of a population of reclined 50%ile (in terms of height and weight) male occupants, subjected to restraint variability in a semi-rigid seat setup, was analyzed through finite element human body model (FE-HBM) simulations (n = 369). To account for the substantial individual variability associated with pelvic shape, a statistical shape model was utilized to predict a large set of random 50%ile male pelvises. Based on select measurements, a sub-sample was drawn from this set (n = 78) for inclusion in the analysis. The simulated submarining outcome and corresponding occupant/restraint parameters were used to generate a metamodel predicting probability of submarining.</p><p><strong>Results: </strong>The results showed that random variations of a 50%ile male can be comparable with restraint design variability on submarining outcome for reclined occupants. Significant predictors included three from the occupant (pelvis angle, iliac spine hook angle, and H-Point forward/rearward position), and three from the restraint (buckle angle, seat friction, and seat pan angle). Non-significant predictors included occupant soft tissue thickness and fat stiffness, shoulder belt load limit force, and inclusion/exclusion of single lap belt pre-tensioning.</p><p><strong>Discussion: </strong>In conclusion, this study implies that future vehicle safety ratings, using different versions of a 50%ile male FE-HBM, may be subject to variation in submarining outcome if harmonization of the target occupant anatomy/posture is not established. In addition, based on the response in a semi-rigid seat setup, this study also indicates that to achieve robust submarining protection for reclined occupants, the current legal requirements on buckle angle might need a shift towards more vertical angles.</p>","PeriodicalId":12444,"journal":{"name":"Frontiers in Bioengineering and Biotechnology","volume":"13 ","pages":"1570572"},"PeriodicalIF":4.3000,"publicationDate":"2025-07-09","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12283681/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Frontiers in Bioengineering and Biotechnology","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.3389/fbioe.2025.1570572","RegionNum":3,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q1","JCRName":"BIOTECHNOLOGY & APPLIED MICROBIOLOGY","Score":null,"Total":0}
引用次数: 0
Abstract
Introduction: In future autonomous vehicles, a greater seat back recline angle has been suggested to accommodate a more relaxed occupant position. Due to the reclined position, the pelvis rotates rearward resulting in less favorable in-crash pelvis to lap belt interaction. In a crash, this issue can increase the likelihood of the lap belt disengaging from the pelvis and instead loading the abdomen, i.e., submarining. Hence, to enable assessment of submarining prevention measures for reclined occupants in frontal car crash scenarios, it is motivated to enhance the understanding of pelvis to lap belt interaction.
Method: In this simulation study, the submarining outcome of a population of reclined 50%ile (in terms of height and weight) male occupants, subjected to restraint variability in a semi-rigid seat setup, was analyzed through finite element human body model (FE-HBM) simulations (n = 369). To account for the substantial individual variability associated with pelvic shape, a statistical shape model was utilized to predict a large set of random 50%ile male pelvises. Based on select measurements, a sub-sample was drawn from this set (n = 78) for inclusion in the analysis. The simulated submarining outcome and corresponding occupant/restraint parameters were used to generate a metamodel predicting probability of submarining.
Results: The results showed that random variations of a 50%ile male can be comparable with restraint design variability on submarining outcome for reclined occupants. Significant predictors included three from the occupant (pelvis angle, iliac spine hook angle, and H-Point forward/rearward position), and three from the restraint (buckle angle, seat friction, and seat pan angle). Non-significant predictors included occupant soft tissue thickness and fat stiffness, shoulder belt load limit force, and inclusion/exclusion of single lap belt pre-tensioning.
Discussion: In conclusion, this study implies that future vehicle safety ratings, using different versions of a 50%ile male FE-HBM, may be subject to variation in submarining outcome if harmonization of the target occupant anatomy/posture is not established. In addition, based on the response in a semi-rigid seat setup, this study also indicates that to achieve robust submarining protection for reclined occupants, the current legal requirements on buckle angle might need a shift towards more vertical angles.
期刊介绍:
The translation of new discoveries in medicine to clinical routine has never been easy. During the second half of the last century, thanks to the progress in chemistry, biochemistry and pharmacology, we have seen the development and the application of a large number of drugs and devices aimed at the treatment of symptoms, blocking unwanted pathways and, in the case of infectious diseases, fighting the micro-organisms responsible. However, we are facing, today, a dramatic change in the therapeutic approach to pathologies and diseases. Indeed, the challenge of the present and the next decade is to fully restore the physiological status of the diseased organism and to completely regenerate tissue and organs when they are so seriously affected that treatments cannot be limited to the repression of symptoms or to the repair of damage. This is being made possible thanks to the major developments made in basic cell and molecular biology, including stem cell science, growth factor delivery, gene isolation and transfection, the advances in bioengineering and nanotechnology, including development of new biomaterials, biofabrication technologies and use of bioreactors, and the big improvements in diagnostic tools and imaging of cells, tissues and organs.
In today`s world, an enhancement of communication between multidisciplinary experts, together with the promotion of joint projects and close collaborations among scientists, engineers, industry people, regulatory agencies and physicians are absolute requirements for the success of any attempt to develop and clinically apply a new biological therapy or an innovative device involving the collective use of biomaterials, cells and/or bioactive molecules. “Frontiers in Bioengineering and Biotechnology” aspires to be a forum for all people involved in the process by bridging the gap too often existing between a discovery in the basic sciences and its clinical application.