Reproducibility in the identification of retinal positions on serial fundus photographs: Theory and limitations.

IF 2.8 3区 医学 Q1 OPHTHALMOLOGY
Toke Bek, Giovanni Ometto
{"title":"Reproducibility in the identification of retinal positions on serial fundus photographs: Theory and limitations.","authors":"Toke Bek, Giovanni Ometto","doi":"10.1111/aos.17566","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Imaging of the retina is accompanied by distortions so that positions in fundus photographs cannot be linearly translated to positions in the retinal fundus. The purpose of this study was to describe an algorithm and evaluate its reproducibility in identifying points on the retina from their representation on serial fundus photographs.</p><p><strong>Methods: </strong>A mathematical formalism was derived to describe how the location of the fovea and the optic disc in fundus photographs, together with the centre-nodal point distance (d) and the curvature radius (r) of the eye, can be used to calculate spatial coordinates on the retina that correspond to given locations in the photograph. The effect of manual markings of the fovea and the optic disc as reference points was evaluated, and the formalism was tested on 105 photographs recorded with different image modalities and centring from 10 different patients.</p><p><strong>Results: </strong>Retinal locations could be identified in serial fundus photographs with a reproducibility of at least 50 μm when the centre-nodal point distance and the curvature radius were set to those in Gullstrand's standard eye. A main source of the variability was the manual identification of the fovea and optic disc used as reference points.</p><p><strong>Conclusions: </strong>The reproducibility in the identification of locations on the retina from serial fundus photographs depends on the accuracy in the definition of the fovea and optic disc used as reference points. This affects the potential for describing locations, distances, areas and changes in retinal lesions on serial photographs over time.</p>","PeriodicalId":6915,"journal":{"name":"Acta Ophthalmologica","volume":" ","pages":""},"PeriodicalIF":2.8000,"publicationDate":"2025-07-24","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Acta Ophthalmologica","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1111/aos.17566","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Imaging of the retina is accompanied by distortions so that positions in fundus photographs cannot be linearly translated to positions in the retinal fundus. The purpose of this study was to describe an algorithm and evaluate its reproducibility in identifying points on the retina from their representation on serial fundus photographs.

Methods: A mathematical formalism was derived to describe how the location of the fovea and the optic disc in fundus photographs, together with the centre-nodal point distance (d) and the curvature radius (r) of the eye, can be used to calculate spatial coordinates on the retina that correspond to given locations in the photograph. The effect of manual markings of the fovea and the optic disc as reference points was evaluated, and the formalism was tested on 105 photographs recorded with different image modalities and centring from 10 different patients.

Results: Retinal locations could be identified in serial fundus photographs with a reproducibility of at least 50 μm when the centre-nodal point distance and the curvature radius were set to those in Gullstrand's standard eye. A main source of the variability was the manual identification of the fovea and optic disc used as reference points.

Conclusions: The reproducibility in the identification of locations on the retina from serial fundus photographs depends on the accuracy in the definition of the fovea and optic disc used as reference points. This affects the potential for describing locations, distances, areas and changes in retinal lesions on serial photographs over time.

在连续眼底照片视网膜位置识别的再现性:理论和局限性。
背景:视网膜成像伴随着畸变,因此眼底照片中的位置不能线性地转化为视网膜眼底的位置。本研究的目的是描述一种算法,并评估其在识别视网膜上的点的再现性,从他们的表现在连续眼底照片。方法:导出了一种数学形式来描述眼底照片中中央凹和视盘的位置,以及眼睛的中心节点距离(d)和曲率半径(r),如何用于计算视网膜上与照片中给定位置对应的空间坐标。评估了中央凹和视盘作为参考点的手工标记的效果,并对来自10名不同患者的105张不同图像模式和定心记录的照片进行了形式性测试。结果:当中心节点距离和曲率半径设置为Gullstrand标准眼时,可以在连续眼底照片中识别视网膜位置,其重复性至少为50 μm。可变性的主要来源是人工识别中央凹和视盘作为参考点。结论:从连续眼底照片中识别视网膜位置的可重复性取决于作为参考点的中央凹和视盘定义的准确性。这影响了描述位置、距离、区域和视网膜病变随时间变化的可能性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Acta Ophthalmologica
Acta Ophthalmologica 医学-眼科学
CiteScore
7.60
自引率
5.90%
发文量
433
审稿时长
6 months
期刊介绍: Acta Ophthalmologica is published on behalf of the Acta Ophthalmologica Scandinavica Foundation and is the official scientific publication of the following societies: The Danish Ophthalmological Society, The Finnish Ophthalmological Society, The Icelandic Ophthalmological Society, The Norwegian Ophthalmological Society and The Swedish Ophthalmological Society, and also the European Association for Vision and Eye Research (EVER). Acta Ophthalmologica publishes clinical and experimental original articles, reviews, editorials, educational photo essays (Diagnosis and Therapy in Ophthalmology), case reports and case series, letters to the editor and doctoral theses.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信