Echocardiography-Guided Percutaneous Patent Ductus Arteriosus Closure: A Prospective Trial at High Altitude.

Hongliang Wei, Luxi Guan, Dong Luo, Zhengwei Li, Ping Ni, Zhuoga Danzeng, Zheng Ban, Xiangbin Pan, Luobu Gesang, Haibo Hu
{"title":"Echocardiography-Guided Percutaneous Patent Ductus Arteriosus Closure: A Prospective Trial at High Altitude.","authors":"Hongliang Wei, Luxi Guan, Dong Luo, Zhengwei Li, Ping Ni, Zhuoga Danzeng, Zheng Ban, Xiangbin Pan, Luobu Gesang, Haibo Hu","doi":"10.1002/ccd.70044","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To explore the clinical efficacy and safety of interventional closure of patent ductus arteriosus (PDA) via femoral venous puncture under echocardiography guidance at high altitude.</p><p><strong>Methods: </strong>From December 2022 to July 2023, 36 patients with PDA at high altitude were prospectively enrolled and underwent closure either under echocardiography guidance or fluoroscopy guidance. Baseline, procedural, and outcome characteristics were compared in intention-to-treat analysis.</p><p><strong>Results: </strong>The characteristics of patients and PDA were comparable between the two groups. The success rate of occlusion was 100% in both groups. Compared with the traditional fluoroscopy group, the echocardiography group showed a significant reduction in Air Kerma (112.13 ± 77.51 Gy vs. 247.27 ± 123.81 Gy, p = 0.001), Dose Area Product (24.3 [13.6-31.3] Gy·cm<sup>2</sup> vs. 41.5 [26.9-63.5] Gy·cm<sup>2</sup>, p = 0.015) and intraoperative contrast dose (0 vs. 1.74 ± 1.02 mL/kg, p < 0.001). In the fluoroscopy group, a significant rise in creatinine (60.47 ± 14.02 umol/L vs. 40.93 ± 14.94 umol/L, p < 0.001) and urea nitrogen levels (6.03 ± 1.12 mmol/L vs. 4.80 ± 0.81 mmol/L, p < 0.001) at 24 h postoperatively were detected compared to preoperative levels, whereas no such changes were detected in the echocardiography group. Except for one patient in the fluoroscopy group lost to 1-year follow-up, no adverse events were reported in either group.</p><p><strong>Conclusion: </strong>At high altitude, echocardiography-guided percutaneous PDA closure offers comparable efficacy to traditional methods, with minimal X-ray exposure and no contrast-induced kidney injury.</p><p><strong>Clinical trial registration: </strong>The trial is registered at http://www.chictr.org.cn (ChiCTR2400090901).</p>","PeriodicalId":520583,"journal":{"name":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","volume":" ","pages":""},"PeriodicalIF":0.0000,"publicationDate":"2025-07-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.1002/ccd.70044","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To explore the clinical efficacy and safety of interventional closure of patent ductus arteriosus (PDA) via femoral venous puncture under echocardiography guidance at high altitude.

Methods: From December 2022 to July 2023, 36 patients with PDA at high altitude were prospectively enrolled and underwent closure either under echocardiography guidance or fluoroscopy guidance. Baseline, procedural, and outcome characteristics were compared in intention-to-treat analysis.

Results: The characteristics of patients and PDA were comparable between the two groups. The success rate of occlusion was 100% in both groups. Compared with the traditional fluoroscopy group, the echocardiography group showed a significant reduction in Air Kerma (112.13 ± 77.51 Gy vs. 247.27 ± 123.81 Gy, p = 0.001), Dose Area Product (24.3 [13.6-31.3] Gy·cm2 vs. 41.5 [26.9-63.5] Gy·cm2, p = 0.015) and intraoperative contrast dose (0 vs. 1.74 ± 1.02 mL/kg, p < 0.001). In the fluoroscopy group, a significant rise in creatinine (60.47 ± 14.02 umol/L vs. 40.93 ± 14.94 umol/L, p < 0.001) and urea nitrogen levels (6.03 ± 1.12 mmol/L vs. 4.80 ± 0.81 mmol/L, p < 0.001) at 24 h postoperatively were detected compared to preoperative levels, whereas no such changes were detected in the echocardiography group. Except for one patient in the fluoroscopy group lost to 1-year follow-up, no adverse events were reported in either group.

Conclusion: At high altitude, echocardiography-guided percutaneous PDA closure offers comparable efficacy to traditional methods, with minimal X-ray exposure and no contrast-induced kidney injury.

Clinical trial registration: The trial is registered at http://www.chictr.org.cn (ChiCTR2400090901).

超声心动图引导下经皮动脉导管未闭闭合:一项高海拔地区的前瞻性试验。
目的:探讨高海拔超声心动图引导下经股静脉穿刺介入封堵动脉导管未闭的临床疗效和安全性。方法:从2022年12月至2023年7月,前瞻性纳入36例高海拔PDA患者,在超声心动图或透视引导下进行闭合。在意向治疗分析中比较基线、程序和结局特征。结果:两组患者的特征及PDA具有可比性。两组的封堵成功率均为100%。超声造影组Air Kerma(112.13±77.51 Gy比247.27±123.81 Gy, p = 0.001)、剂量面积积(24.3 [13.6-31.3]Gy·cm2比41.5 [26.9-63.5]Gy·cm2, p = 0.015)、术中造影剂(0比1.74±1.02 mL/kg, p)均显著降低。在高海拔地区,超声心动图引导下经皮PDA闭合术的疗效与传统方法相当,x线暴露最小,无造影剂引起的肾损伤。临床试验注册:该试验在http://www.chictr.org.cn注册(ChiCTR2400090901)。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
自引率
0.00%
发文量
0
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信