[Optimization of low frequency function of vertical semicircular canal in rotating test and analysis of three-dimensional parameters of induced nystagmus].

Q4 Medicine
Y L Chen, C Wang, Y T Liu, Y L Li, X F Li, Y F Lyu, Y D Song, D G Zhang
{"title":"[Optimization of low frequency function of vertical semicircular canal in rotating test and analysis of three-dimensional parameters of induced nystagmus].","authors":"Y L Chen, C Wang, Y T Liu, Y L Li, X F Li, Y F Lyu, Y D Song, D G Zhang","doi":"10.3760/cma.j.cn115330-20240703-00399","DOIUrl":null,"url":null,"abstract":"<p><p><b>Objective:</b> To study the feasibility of detecting vertical semicircular canal function and to analyze the three-dimensional(3D)characteristics and normal reference value in healthy young people. <b>Methods:</b> This was a cross-sectional study conducted from January to June 2024. A three-axis rotating chair was used to perform vertical sinusoidal rotation on 52 healthy young adults (26 males and 26 females, aged 18-40 years) in the left anterior-right posterior (LARP) and right anterior-left posterior (RALP) semicircular canal planes. For each plane, nystagmus was induced with six combinations of different angles and velocity front and back rotation angles of ±30°,±60°,±90°, and velocities of 40°/s and 80°/s, the slow phase velocity (SPV) and their symmetry of 3D nystagmus were analyzed. SPSS 20.0 was used to compare the statistical differences in these two parameters across different stimulation protocols. <b>Results:</b> There were no spontaneous nystagmus in the 52 subjects, and all tests were finished. Except the combinations of (±30°-40°/s), three components of nystagmus were induced stably in the rest of the stimulations. The SPVs of vertical components were no statistically insignificant (<i>P</i>>0.05), and some horizontal or torsion components were statistically significant (<i>P</i><0.05). The 95% reference range of the symmetry was≤25% in the vertical and≤30% in the torsional component of the nystagmus except for (±30°-80°/s), the symmetry was 32.2% and 49.2% respectively. The trend changes of the three components were consistent, among which the vertical and torsional components induced by (±60°-80°/s) and (±90°-80°/s) were the best, the SPV value of the vertical components was higher in the latter group than the former apart from the front RALP, while no significant difference was found in the torsional components (<i>P</i>>0.05). <b>Conclusion:</b> The (±90°-80°/s) combination is the optimal method to detect the function of vertical semicircular canal in 3D chair test. When observing torsional component, the combining scheme of (±60°-80°/s) and (±90°-80°/s) is better. Considering tolerance, the (±60°-80°/s) combination is recommended.</p>","PeriodicalId":23987,"journal":{"name":"Chinese journal of otorhinolaryngology head and neck surgery","volume":"60 6","pages":"630-637"},"PeriodicalIF":0.0000,"publicationDate":"2025-06-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Chinese journal of otorhinolaryngology head and neck surgery","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.3760/cma.j.cn115330-20240703-00399","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"Medicine","Score":null,"Total":0}
引用次数: 0

Abstract

Objective: To study the feasibility of detecting vertical semicircular canal function and to analyze the three-dimensional(3D)characteristics and normal reference value in healthy young people. Methods: This was a cross-sectional study conducted from January to June 2024. A three-axis rotating chair was used to perform vertical sinusoidal rotation on 52 healthy young adults (26 males and 26 females, aged 18-40 years) in the left anterior-right posterior (LARP) and right anterior-left posterior (RALP) semicircular canal planes. For each plane, nystagmus was induced with six combinations of different angles and velocity front and back rotation angles of ±30°,±60°,±90°, and velocities of 40°/s and 80°/s, the slow phase velocity (SPV) and their symmetry of 3D nystagmus were analyzed. SPSS 20.0 was used to compare the statistical differences in these two parameters across different stimulation protocols. Results: There were no spontaneous nystagmus in the 52 subjects, and all tests were finished. Except the combinations of (±30°-40°/s), three components of nystagmus were induced stably in the rest of the stimulations. The SPVs of vertical components were no statistically insignificant (P>0.05), and some horizontal or torsion components were statistically significant (P<0.05). The 95% reference range of the symmetry was≤25% in the vertical and≤30% in the torsional component of the nystagmus except for (±30°-80°/s), the symmetry was 32.2% and 49.2% respectively. The trend changes of the three components were consistent, among which the vertical and torsional components induced by (±60°-80°/s) and (±90°-80°/s) were the best, the SPV value of the vertical components was higher in the latter group than the former apart from the front RALP, while no significant difference was found in the torsional components (P>0.05). Conclusion: The (±90°-80°/s) combination is the optimal method to detect the function of vertical semicircular canal in 3D chair test. When observing torsional component, the combining scheme of (±60°-80°/s) and (±90°-80°/s) is better. Considering tolerance, the (±60°-80°/s) combination is recommended.

[垂直半规管旋转试验低频功能优化及诱发性眼球震颤三维参数分析]。
目的:探讨健康青少年垂直半规管功能检测的可行性,分析其三维特征及正常参考值。方法:采用横断面研究,于2024年1 - 6月进行。采用三轴旋转椅对52例健康青年(男性26例,女性26例,年龄18-40岁)在左前后-右后(LARP)和右前后-左后(RALP)半规管平面进行垂直正弦旋转。在每个平面上,分别以±30°、±60°、±90°、40°/s和80°/s的前后旋转角度和速度的6种不同角度和速度组合诱导眼球震颤,分析三维眼球震颤的慢相速度(SPV)及其对称性。采用SPSS 20.0软件比较不同增产方案下这两个参数的统计学差异。结果:52例患者均无自发性眼球震颤,各项试验均完成。除(±30°-40°/s)组合外,其余刺激均稳定诱导眼球震颤。垂直分量spv差异无统计学意义(P>0.05),部分水平或扭转分量spv差异有统计学意义(P>0.05)。结论:(±90°-80°/s)组合是三维椅试验中检测垂直半圆形管功能的最佳方法。在观测扭转分量时,采用(±60°-80°/s)和(±90°-80°/s)组合方案效果较好。考虑到公差,建议使用(±60°-80°/s)组合。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.40
自引率
0.00%
发文量
12432
期刊介绍: Chinese journal of otorhinolaryngology head and neck surgery is a high-level medical science and technology journal sponsored and published directly by the Chinese Medical Association, reflecting the significant research progress in the field of otorhinolaryngology head and neck surgery in China, and striving to promote the domestic and international academic exchanges for the purpose of running the journal. Over the years, the journal has been ranked first in the total citation frequency list of national scientific and technical journals published by the Documentation and Intelligence Center of the Chinese Academy of Sciences and the China Science Citation Database, and has always ranked first among the scientific and technical journals in the related fields. Chinese journal of otorhinolaryngology head and neck surgery has been included in the authoritative databases PubMed, Chinese core journals, CSCD.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信