Refractive Profile and Angle of Deviation in Patients with Congenital Esotropia and Congenital Exotropia.

IF 1.6 Q3 OPHTHALMOLOGY
Journal of Ophthalmic & Vision Research Pub Date : 2025-06-13 eCollection Date: 2025-01-01 DOI:10.18502/jovr.v20.15066
Masoud Khorrami-Nejad, Mohammad Reza Akbari, Ali Hassan Khaleel, Razieh Bahreini, Foroozan Narooie-Noori, Babak Masoomian
{"title":"Refractive Profile and Angle of Deviation in Patients with Congenital Esotropia and Congenital Exotropia.","authors":"Masoud Khorrami-Nejad, Mohammad Reza Akbari, Ali Hassan Khaleel, Razieh Bahreini, Foroozan Narooie-Noori, Babak Masoomian","doi":"10.18502/jovr.v20.15066","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>To compare refractive error and angle of deviation in patients with congenital esotropia (CET) and congenital exotropia (CXT).</p><p><strong>Methods: </strong>This retrospective study reviewed the medical documents of 246 patients with CET (<i>n</i> = 206) and CXT (<i>n</i> = 40) admitted to Farabi Eye Hospital, Iran, from 2012 to 2022. All patients were between 6 and 12 months old at the time of admission. Refractive error components and angles of deviation in these patients were recorded and analyzed.</p><p><strong>Results: </strong>In patients with CET, the mean sphere, cylinder, and spherical equivalent (SE) were 2.59 ± 2.28 diopters (D), -0.42 ± 0.57 D, and 2.38 ± 2.28 D, respectively. Also, the mean horizontal deviation at near was 45.5 ± 12.3 prism diopters (Δ) (range, 20-98 Δ). The most common range was 44-55 Δ (40%), followed by 33-44 Δ (28%) and 55-65 Δ (12%). On the other hand, the mean sphere, cylinder, and SE in patients with CXT were 1.88 ± 1.84 D, -0.39 ± 0.69 D, and 1.69 ± 1.74 D, respectively. Also, the mean horizontal deviation at near was 45.0 ± 17.1 Δ (range, 20-105 Δ). For the CXT group, deviation ranges of 33-44 Δ (37%), 44-55 Δ (32%), and 22-33 Δ (15%) were most prevalent. The mean sphere and SE were significantly higher in the CET group than in the CXT group (P = 0.010).</p><p><strong>Conclusion: </strong>This study found a distinct refractive profile and distribution of the angle of deviation in patients with CET versus CXT. Patients with CET demonstrated significantly greater hyperopia than those with CXT.</p>","PeriodicalId":16586,"journal":{"name":"Journal of Ophthalmic & Vision Research","volume":"20 ","pages":""},"PeriodicalIF":1.6000,"publicationDate":"2025-06-13","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12258378/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmic & Vision Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/jovr.v20.15066","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: To compare refractive error and angle of deviation in patients with congenital esotropia (CET) and congenital exotropia (CXT).

Methods: This retrospective study reviewed the medical documents of 246 patients with CET (n = 206) and CXT (n = 40) admitted to Farabi Eye Hospital, Iran, from 2012 to 2022. All patients were between 6 and 12 months old at the time of admission. Refractive error components and angles of deviation in these patients were recorded and analyzed.

Results: In patients with CET, the mean sphere, cylinder, and spherical equivalent (SE) were 2.59 ± 2.28 diopters (D), -0.42 ± 0.57 D, and 2.38 ± 2.28 D, respectively. Also, the mean horizontal deviation at near was 45.5 ± 12.3 prism diopters (Δ) (range, 20-98 Δ). The most common range was 44-55 Δ (40%), followed by 33-44 Δ (28%) and 55-65 Δ (12%). On the other hand, the mean sphere, cylinder, and SE in patients with CXT were 1.88 ± 1.84 D, -0.39 ± 0.69 D, and 1.69 ± 1.74 D, respectively. Also, the mean horizontal deviation at near was 45.0 ± 17.1 Δ (range, 20-105 Δ). For the CXT group, deviation ranges of 33-44 Δ (37%), 44-55 Δ (32%), and 22-33 Δ (15%) were most prevalent. The mean sphere and SE were significantly higher in the CET group than in the CXT group (P = 0.010).

Conclusion: This study found a distinct refractive profile and distribution of the angle of deviation in patients with CET versus CXT. Patients with CET demonstrated significantly greater hyperopia than those with CXT.

先天性内斜视和先天性外斜视患者的屈光轮廓和角度偏差。
目的:比较先天性内斜视(CET)和先天性外斜视(CXT)患者的屈光不正和角度偏差。方法:回顾性分析2012 - 2022年伊朗法拉比眼科医院收治的246例CET (n = 206)和CXT (n = 40)患者的医疗资料。所有患者入院时年龄在6至12个月之间。记录并分析这些患者的屈光不正成分和偏角。结果:CET患者的平均球、柱、球等效(SE)分别为2.59±2.28屈光度(D)、-0.42±0.57 D、2.38±2.28 D。近距离平均水平偏差为45.5±12.3棱镜屈光度(Δ)(范围20-98 Δ)。最常见的是44-55岁Δ(40%),其次是33-44岁Δ(28%)和55-65岁Δ(12%)。而CXT患者的平均球、柱、SE分别为1.88±1.84 D、-0.39±0.69 D、1.69±1.74 D。附近的平均水平偏差为45.0±17.1 Δ(范围20-105 Δ)。对于CXT组,偏差范围为33-44 Δ (37%), 44-55 Δ(32%)和22-33 Δ(15%)。CET组的平均球和SE明显高于CXT组(P = 0.010)。结论:本研究发现CET与CXT患者有明显的屈光分布和偏角分布。CET患者的远视明显高于CXT患者。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
63
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信