A New Complementary Touch for the Temporal Inverted Internal Limiting Membrane Flap Technique.

IF 1.5 Q3 OPHTHALMOLOGY
Journal of Ophthalmic & Vision Research Pub Date : 2025-05-05 eCollection Date: 2025-01-01 DOI:10.18502/jovr.v20.14516
Levent Karabas, Ecem Önder Tokuç, Sevim Ayça Seyyar, Özlem Şahin
{"title":"A New Complementary Touch for the Temporal Inverted Internal Limiting Membrane Flap Technique.","authors":"Levent Karabas, Ecem Önder Tokuç, Sevim Ayça Seyyar, Özlem Şahin","doi":"10.18502/jovr.v20.14516","DOIUrl":null,"url":null,"abstract":"<p><p>The temporal inverted internal limiting membrane (ILM) flap technique was developed to improve vitreoretinal surgery for large macular holes (MH). However, in addition to the difficulty of the surgical procedure, the main concern is the displacement of the ILM flap due to small fluid leakage into the posterior pole, even in the short time required to close the sclerotomies after fluid-air exchange. A new approach to the temporal inverted ILM flap technique is described here. In this approach, when the ILM flap is inverted over the MH, ILM forceps, while it is closed, are gently pressed over the folded edge and passed over (just like folding a paper in half), creating an ILM fold mark like the ones used in origami. Thus, it can be seen that the minimal fluid leaking into the posterior pole ventilates the free edge of the flap, but the force formed along the folded edge prevents the flap turnover.</p>","PeriodicalId":16586,"journal":{"name":"Journal of Ophthalmic & Vision Research","volume":"20 ","pages":""},"PeriodicalIF":1.5000,"publicationDate":"2025-05-05","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12257984/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Ophthalmic & Vision Research","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.18502/jovr.v20.14516","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/1/1 0:00:00","PubModel":"eCollection","JCR":"Q3","JCRName":"OPHTHALMOLOGY","Score":null,"Total":0}
引用次数: 0

Abstract

The temporal inverted internal limiting membrane (ILM) flap technique was developed to improve vitreoretinal surgery for large macular holes (MH). However, in addition to the difficulty of the surgical procedure, the main concern is the displacement of the ILM flap due to small fluid leakage into the posterior pole, even in the short time required to close the sclerotomies after fluid-air exchange. A new approach to the temporal inverted ILM flap technique is described here. In this approach, when the ILM flap is inverted over the MH, ILM forceps, while it is closed, are gently pressed over the folded edge and passed over (just like folding a paper in half), creating an ILM fold mark like the ones used in origami. Thus, it can be seen that the minimal fluid leaking into the posterior pole ventilates the free edge of the flap, but the force formed along the folded edge prevents the flap turnover.

颞部倒置内限制膜瓣技术的一种新的补充方法。
为了改善大黄斑孔的玻璃体视网膜手术,提出了颞部倒置内限制膜(ILM)瓣技术。然而,除了手术难度外,主要的问题是由于少量液体漏入后极而导致ILM瓣移位,即使在短时间内关闭液气交换后的巩膜切开术。本文介绍了一种颞内逆行ILM皮瓣的新方法。在这种方法中,当ILM皮瓣倒置在MH上时,ILM钳,当它关闭时,轻轻地压在折叠边缘上并通过(就像把纸对折一样),创造一个ILM折叠标记,就像折纸中使用的那样。由此可见,漏入后极的最小流体使皮瓣自由边缘通风,但沿折叠边缘形成的力阻止了皮瓣翻转。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
3.60
自引率
0.00%
发文量
63
审稿时长
30 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信