{"title":"A Novel Method for Functional Assessment of the Stenosis of the Anterior Cerebral Circulation.","authors":"Long Yu, Deyuan Zhu, Yunhan Cai, Yibin Fang, Shengzhang Wang","doi":"10.1007/s10439-025-03810-2","DOIUrl":null,"url":null,"abstract":"<p><strong>Purpose: </strong>The cerebral anterior circulation arteries are the primary vessels supplying blood to the brain, and severe stenosis in these arteries can lead to ischemic stroke. Traditional imaging-based methods for assessing stenosis severity primarily focus on the diameter reduction at the narrowest point, which often fails to accurately reflect the functional severity of arterial stenosis. The FFR is considered the gold standard for assessing coronary artery stenosis. This study aims to revisit the original definition of FFR and develop a method for functionally assessing stenosis in the cerebral anterior circulation arteries.</p><p><strong>Methods: </strong>Patient-specific artery models representing both stenosed and post-repair conditions were generated based on clinical data. Numerical simulation models were then developed, and BFFR was calculated as an assessment metric. The accuracy of the numerical simulation model was validated through in vitro experiments.</p><p><strong>Results: </strong>The average bifurcation coefficient across the 9 cases was 2.82. The numerical simulation results for all cases were consistent with the clinical CTP measurements, accurately distinguishing the relative blood flow between the left and right arteries. The mean BFFR <math><mmultiscripts><mrow></mrow> <mrow><mi>min</mi></mrow> <mrow></mrow></mmultiscripts> </math> for patients with mild stenosis was 1.53 times higher than that of patients with moderate and severe stenosis. The relative error between the total flow obtained from the numerical simulations and the experimental measurements was less than 3%.</p><p><strong>Conclusion: </strong>Compared to traditional diameter stenosis rates, BFFR offers a significant advantage in evaluating cerebral artery stenosis. Furthermore, the numerical simulation model developed in this study demonstrated high accuracy.</p>","PeriodicalId":7986,"journal":{"name":"Annals of Biomedical Engineering","volume":" ","pages":""},"PeriodicalIF":5.4000,"publicationDate":"2025-07-21","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Annals of Biomedical Engineering","FirstCategoryId":"5","ListUrlMain":"https://doi.org/10.1007/s10439-025-03810-2","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q3","JCRName":"ENGINEERING, BIOMEDICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Purpose: The cerebral anterior circulation arteries are the primary vessels supplying blood to the brain, and severe stenosis in these arteries can lead to ischemic stroke. Traditional imaging-based methods for assessing stenosis severity primarily focus on the diameter reduction at the narrowest point, which often fails to accurately reflect the functional severity of arterial stenosis. The FFR is considered the gold standard for assessing coronary artery stenosis. This study aims to revisit the original definition of FFR and develop a method for functionally assessing stenosis in the cerebral anterior circulation arteries.

Methods: Patient-specific artery models representing both stenosed and post-repair conditions were generated based on clinical data. Numerical simulation models were then developed, and BFFR was calculated as an assessment metric. The accuracy of the numerical simulation model was validated through in vitro experiments.

Results: The average bifurcation coefficient across the 9 cases was 2.82. The numerical simulation results for all cases were consistent with the clinical CTP measurements, accurately distinguishing the relative blood flow between the left and right arteries. The mean BFFR min for patients with mild stenosis was 1.53 times higher than that of patients with moderate and severe stenosis. The relative error between the total flow obtained from the numerical simulations and the experimental measurements was less than 3%.

Conclusion: Compared to traditional diameter stenosis rates, BFFR offers a significant advantage in evaluating cerebral artery stenosis. Furthermore, the numerical simulation model developed in this study demonstrated high accuracy.

一种评估脑前循环狭窄功能的新方法。
目的:大脑前循环动脉是向大脑供血的主要血管,这些动脉的严重狭窄可导致缺血性中风。传统的基于影像学的狭窄程度评估方法主要集中在最窄点的内径缩小,往往不能准确反映动脉狭窄的功能严重程度。FFR被认为是评估冠状动脉狭窄的金标准。本研究旨在重新审视FFR的原始定义,并开发一种功能性评估脑前循环动脉狭窄的方法。方法:根据临床数据,生成代表狭窄和修复后情况的患者特异性动脉模型。然后建立数值模拟模型,并计算BFFR作为评估指标。通过体外实验验证了数值模拟模型的准确性。结果:9例患者的平均分岔系数为2.82。所有病例的数值模拟结果与临床CTP测量结果一致,准确区分了左右动脉的相对血流量。轻度狭窄患者的平均BFFR min是中度和重度狭窄患者的1.53倍。数值模拟得到的总流量与实验测量值的相对误差小于3%。结论:与传统的直径狭窄率相比,BFFR在评估脑动脉狭窄方面具有显著优势。此外,本研究建立的数值模拟模型具有较高的精度。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Annals of Biomedical Engineering
Annals of Biomedical Engineering 工程技术-工程:生物医学
CiteScore
7.50
自引率
15.80%
发文量
212
审稿时长
3 months
期刊介绍: Annals of Biomedical Engineering is an official journal of the Biomedical Engineering Society, publishing original articles in the major fields of bioengineering and biomedical engineering. The Annals is an interdisciplinary and international journal with the aim to highlight integrated approaches to the solutions of biological and biomedical problems.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信