Response Surface Methodology-Based Extraction of Fumaric Acid From Fumaria officinalis L. and Quantification by RP-HPLC

IF 1.8 4区 医学 Q4 BIOCHEMICAL RESEARCH METHODS
Gunay Mammadova, Pelin Koseoglu-Yilmaz
{"title":"Response Surface Methodology-Based Extraction of Fumaric Acid From Fumaria officinalis L. and Quantification by RP-HPLC","authors":"Gunay Mammadova,&nbsp;Pelin Koseoglu-Yilmaz","doi":"10.1002/bmc.70173","DOIUrl":null,"url":null,"abstract":"<div>\n \n <p>In the present study, it was aimed to optimize the extraction of fumaric acid from <i>Fumaria officinalis</i> L. by response surface methodology and its quantification by a newly developed and validated reverse phase high performance liquid chromatography method. Chromatographic separations were performed at 40°C with a C18 column. Aqueous o-phosphoric acid solution and methanol were used as the mobile phase by gradient elution. The flow rate was set at 1.0 mL/min, and the injection volume was 20 μL. Fumaric acid was detected at 215 nm with a UV detector. The method was linear in the range of 10.00–200.00 μg/mL. The limits of detection and quantification were 3.02 μg/mL and 9.15 μg/mL, respectively. The relative mean errors were ≤ 3.77%, whereas the relative standard deviation values were calculated as ≤ 0.48%. The conditions to obtain an extract with high fumaric acid content were optimized by central composite design, a type of response surface methodology. The independent variables were extraction time, solvent volume, and temperature for the maceration procedure, where fumaric acid concentration was the response. The experimental model was evaluated statistically and found to fit well, considering the lack-of-fit <i>p</i> value of 0.211 and coefficient of determination 0.9862 at a confidence level of 95%.</p>\n </div>","PeriodicalId":8861,"journal":{"name":"Biomedical Chromatography","volume":"39 9","pages":""},"PeriodicalIF":1.8000,"publicationDate":"2025-07-22","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical Chromatography","FirstCategoryId":"3","ListUrlMain":"https://onlinelibrary.wiley.com/doi/10.1002/bmc.70173","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0

Abstract

In the present study, it was aimed to optimize the extraction of fumaric acid from Fumaria officinalis L. by response surface methodology and its quantification by a newly developed and validated reverse phase high performance liquid chromatography method. Chromatographic separations were performed at 40°C with a C18 column. Aqueous o-phosphoric acid solution and methanol were used as the mobile phase by gradient elution. The flow rate was set at 1.0 mL/min, and the injection volume was 20 μL. Fumaric acid was detected at 215 nm with a UV detector. The method was linear in the range of 10.00–200.00 μg/mL. The limits of detection and quantification were 3.02 μg/mL and 9.15 μg/mL, respectively. The relative mean errors were ≤ 3.77%, whereas the relative standard deviation values were calculated as ≤ 0.48%. The conditions to obtain an extract with high fumaric acid content were optimized by central composite design, a type of response surface methodology. The independent variables were extraction time, solvent volume, and temperature for the maceration procedure, where fumaric acid concentration was the response. The experimental model was evaluated statistically and found to fit well, considering the lack-of-fit p value of 0.211 and coefficient of determination 0.9862 at a confidence level of 95%.

基于响应面法的富马酸提取及反相高效液相色谱定量研究
本研究采用响应面法对富马酸的提取工艺进行优化,并采用新建立的反相高效液相色谱法对富马酸进行定量分析。采用C18柱,在40℃下进行色谱分离。以邻磷酸水溶液和甲醇为流动相,进行梯度洗脱。流速1.0 mL/min,进样量20 μL。用紫外检测器在215 nm处检测富马酸。该方法在10.00 ~ 200.00 μg/mL范围内呈线性。检测限为3.02 μg/mL,定量限为9.15 μg/mL。相对平均误差≤3.77%,相对标准偏差值≤0.48%。采用响应面法——中心复合设计优化了富马酸高含量提取物的提取条件。自变量为浸出时间、溶剂体积和浸出温度,其中富马酸浓度是响应。在95%的置信水平下,考虑到缺乏拟合的p值为0.211,决定系数为0.9862,对实验模型进行统计评估,发现拟合良好。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Biomedical Chromatography
Biomedical Chromatography 生物-分析化学
CiteScore
3.60
自引率
5.60%
发文量
268
审稿时长
2.3 months
期刊介绍: Biomedical Chromatography is devoted to the publication of original papers on the applications of chromatography and allied techniques in the biological and medical sciences. Research papers and review articles cover the methods and techniques relevant to the separation, identification and determination of substances in biochemistry, biotechnology, molecular biology, cell biology, clinical chemistry, pharmacology and related disciplines. These include the analysis of body fluids, cells and tissues, purification of biologically important compounds, pharmaco-kinetics and sequencing methods using HPLC, GC, HPLC-MS, TLC, paper chromatography, affinity chromatography, gel filtration, electrophoresis and related techniques.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信