Adam A Moreno, Lauren Thielen, Marina Liles, Minh Huynh, David Sanchez-Migallon Guzman, Julianne N Richard, Chaowaphan Yinharnmingmongkol, Nicola Di Girolamo
{"title":"Accidental acute lidocaine toxicity in 6 pet rabbits from multiple institutions and treatment with intravenous lipid emulsion.","authors":"Adam A Moreno, Lauren Thielen, Marina Liles, Minh Huynh, David Sanchez-Migallon Guzman, Julianne N Richard, Chaowaphan Yinharnmingmongkol, Nicola Di Girolamo","doi":"10.2460/javma.25.04.0273","DOIUrl":null,"url":null,"abstract":"<p><strong>Objective: </strong>To describe the signs, treatments, and outcomes of rabbits with lidocaine toxicoses after receiving accidental overdose with IV lidocaine.</p><p><strong>Animals: </strong>6 client-owned rabbits with lidocaine toxicosis following accidental overdoses of 2% lidocaine administered intravenously as a constant rate infusion (> 100 µg/kg/min) or bolus (> 2 mg/kg) were identified through medical record searches at 4 institutions, covering cases from July 18, 1974, to September 15, 2024, depending on each institution's available records. Rabbits were excluded if they received lower doses or did not subsequently develop abnormal signs.</p><p><strong>Clinical presentation: </strong>5 rabbits showed neurological signs ranging from tremors to seizures, 1 rabbit showed arrhythmia, and 1 rabbit collapsed suddenly.</p><p><strong>Results: </strong>All rabbits received a constant rate infusion of lidocaine as part of their treatment plan. In 3 cases, the lidocaine was administered erroneously at the rate of the IV fluids. These rabbits received doses between 30.6 and 61.6 mg/kg of lidocaine over 30 to 40 minutes before showing signs of neurotoxicity and cardiotoxicity. In 3 cases, an excessive bolus of lidocaine was erroneously administered, ranging between 15.5 and 19 mg/kg. Five of the rabbits were treated with IV lipid emulsion. Potential cardiopulmonary complications were seen in 2 of the rabbits receiving ILE, possibly due to fluid overload. Clinical signs resolved in 4 rabbits, while 2 rabbits died within 24 hours.</p><p><strong>Clinical relevance: </strong>Lidocaine boluses and constant rate infusions in rabbits should be carefully verified to ensure administration of the intended dose. Further investigation into the safety and efficacy of lipid emulsion in these cases is warranted.</p>","PeriodicalId":14658,"journal":{"name":"Javma-journal of The American Veterinary Medical Association","volume":" ","pages":"1-7"},"PeriodicalIF":1.6000,"publicationDate":"2025-07-18","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Javma-journal of The American Veterinary Medical Association","FirstCategoryId":"97","ListUrlMain":"https://doi.org/10.2460/javma.25.04.0273","RegionNum":2,"RegionCategory":"农林科学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"VETERINARY SCIENCES","Score":null,"Total":0}
引用次数: 0
Abstract
Objective: To describe the signs, treatments, and outcomes of rabbits with lidocaine toxicoses after receiving accidental overdose with IV lidocaine.
Animals: 6 client-owned rabbits with lidocaine toxicosis following accidental overdoses of 2% lidocaine administered intravenously as a constant rate infusion (> 100 µg/kg/min) or bolus (> 2 mg/kg) were identified through medical record searches at 4 institutions, covering cases from July 18, 1974, to September 15, 2024, depending on each institution's available records. Rabbits were excluded if they received lower doses or did not subsequently develop abnormal signs.
Clinical presentation: 5 rabbits showed neurological signs ranging from tremors to seizures, 1 rabbit showed arrhythmia, and 1 rabbit collapsed suddenly.
Results: All rabbits received a constant rate infusion of lidocaine as part of their treatment plan. In 3 cases, the lidocaine was administered erroneously at the rate of the IV fluids. These rabbits received doses between 30.6 and 61.6 mg/kg of lidocaine over 30 to 40 minutes before showing signs of neurotoxicity and cardiotoxicity. In 3 cases, an excessive bolus of lidocaine was erroneously administered, ranging between 15.5 and 19 mg/kg. Five of the rabbits were treated with IV lipid emulsion. Potential cardiopulmonary complications were seen in 2 of the rabbits receiving ILE, possibly due to fluid overload. Clinical signs resolved in 4 rabbits, while 2 rabbits died within 24 hours.
Clinical relevance: Lidocaine boluses and constant rate infusions in rabbits should be carefully verified to ensure administration of the intended dose. Further investigation into the safety and efficacy of lipid emulsion in these cases is warranted.
期刊介绍:
Published twice monthly, this peer-reviewed, general scientific journal provides reports of clinical research, feature articles and regular columns of interest to veterinarians in private and public practice. The News and Classified Ad sections are posted online 10 days to two weeks before they are delivered in print.