Evaluation of color stability and surface roughness of smart monochromatic resin composite in comparison to universal resin composites after immersion in staining solutions.

IF 3.1 2区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Ammar Shawkat Abdul Kareem, Wegdan Mohamed Abdel-Fattah, Marihan Ibrahim Lotfy El Gayar
{"title":"Evaluation of color stability and surface roughness of smart monochromatic resin composite in comparison to universal resin composites after immersion in staining solutions.","authors":"Ammar Shawkat Abdul Kareem, Wegdan Mohamed Abdel-Fattah, Marihan Ibrahim Lotfy El Gayar","doi":"10.1186/s12903-025-06555-5","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The color stability and surface roughness of resin composites are the primary factors influencing the qualities of restorative materials. This study aimed to assess the color stability and surface roughness of a smart monochromatic resin composite submerged in various staining solutions.</p><p><strong>Materials and methods: </strong>Ninety-nine disc samples of composite resins (8 mm in diameter and 2 mm in thickness) were prepared and divided into three groups (n = 33): Group A, Omnichroma (Tokuyama Dental, Tokyo, Japan); Group B, Neo Spectra ST HV (Dentsply, Konstanz, Germany); and Group C, Filtek Z350XT (3MESPE) composite resins. The samples were assessed for color stability (M) via a Vita Easyshade spectrophotometer and surface roughness (Ra) with a profilometer before and after thermocycling for a total of 1000 cycles at 5°/55°C with a 15-second dwell time. Each group was subdivided into three subgroups according to immersion solution (n = 11): Subgroup I was submerged in distilled water as a control, Subgroup II was submerged in tea, and Subgroup III was submerged in coffee. Color assessment was performed after immersion periods of T1: 7 days, T2: 15 days, and T3: 30 days with a Vita Easyshade spectrophotometer. A color change (∆E00) was obtained via the CIEDE2000 color difference formula. Surface roughness was assessed with a profilometer after 30 days of submersion in the staining solutions.</p><p><strong>Results: </strong>Among all the samples in the study groups, Omnichroma had the lowest color change value for all the immersion solutions at different time intervals (p < 0.001). The surface roughness of Omnichroma significantly differed after thermocycling (P = 0.075). However, Omnichroma had the least surface roughness compared with Neo Spectra ST HV (P = 0.026) and Filtek Z350XT (P = 0.024).</p><p><strong>Conclusion: </strong>The color change and surface roughness of the supra-nanofilled (Omnichroma) resin-based composite were inferior to those of the nanohybrid (Neo Spectra) and nanofilled (Filtek Z350XT) composites.</p>","PeriodicalId":9072,"journal":{"name":"BMC Oral Health","volume":"25 1","pages":"1211"},"PeriodicalIF":3.1000,"publicationDate":"2025-07-19","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12276654/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"BMC Oral Health","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1186/s12903-025-06555-5","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Background: The color stability and surface roughness of resin composites are the primary factors influencing the qualities of restorative materials. This study aimed to assess the color stability and surface roughness of a smart monochromatic resin composite submerged in various staining solutions.

Materials and methods: Ninety-nine disc samples of composite resins (8 mm in diameter and 2 mm in thickness) were prepared and divided into three groups (n = 33): Group A, Omnichroma (Tokuyama Dental, Tokyo, Japan); Group B, Neo Spectra ST HV (Dentsply, Konstanz, Germany); and Group C, Filtek Z350XT (3MESPE) composite resins. The samples were assessed for color stability (M) via a Vita Easyshade spectrophotometer and surface roughness (Ra) with a profilometer before and after thermocycling for a total of 1000 cycles at 5°/55°C with a 15-second dwell time. Each group was subdivided into three subgroups according to immersion solution (n = 11): Subgroup I was submerged in distilled water as a control, Subgroup II was submerged in tea, and Subgroup III was submerged in coffee. Color assessment was performed after immersion periods of T1: 7 days, T2: 15 days, and T3: 30 days with a Vita Easyshade spectrophotometer. A color change (∆E00) was obtained via the CIEDE2000 color difference formula. Surface roughness was assessed with a profilometer after 30 days of submersion in the staining solutions.

Results: Among all the samples in the study groups, Omnichroma had the lowest color change value for all the immersion solutions at different time intervals (p < 0.001). The surface roughness of Omnichroma significantly differed after thermocycling (P = 0.075). However, Omnichroma had the least surface roughness compared with Neo Spectra ST HV (P = 0.026) and Filtek Z350XT (P = 0.024).

Conclusion: The color change and surface roughness of the supra-nanofilled (Omnichroma) resin-based composite were inferior to those of the nanohybrid (Neo Spectra) and nanofilled (Filtek Z350XT) composites.

评价智能单色树脂复合材料与通用树脂复合材料在染色溶液浸泡后的颜色稳定性和表面粗糙度。
背景:树脂复合材料的颜色稳定性和表面粗糙度是影响修复材料质量的主要因素。本研究旨在评估智能单色树脂复合材料在不同染色溶液中的颜色稳定性和表面粗糙度。材料与方法:制备直径8 mm、厚度2 mm的复合树脂膜片样品99个,分为3组(n = 33): A组,Omnichroma (Tokuyama Dental, Tokyo, Japan);B组,Neo Spectra ST HV (Dentsply, Konstanz, Germany);C组为Filtek Z350XT (3MESPE)复合树脂。通过Vita Easyshade分光光度计和轮廓仪评估样品在热循环前后的颜色稳定性(M)和表面粗糙度(Ra),在5°/55°C下进行共1000次循环,停留时间为15秒。每组按浸泡溶液再分为3个亚组(n = 11):亚组I浸泡在蒸馏水中作为对照,亚组II浸泡在茶中,亚组III浸泡在咖啡中。在T1: 7天、T2: 15天和T3: 30天浸泡后,使用Vita Easyshade分光光度计进行颜色评估。通过CIEDE2000色差公式得出颜色变化∆E00。在染色溶液中浸泡30天后,用轮廓仪评估表面粗糙度。结果:在所有研究组样品中,Omnichroma在不同时间间隔的浸液中颜色变化值最低(p)。结论:超纳米填充(Omnichroma)树脂基复合材料的颜色变化和表面粗糙度均低于纳米混合(Neo Spectra)和纳米填充(Filtek Z350XT)复合材料。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
BMC Oral Health
BMC Oral Health DENTISTRY, ORAL SURGERY & MEDICINE-
CiteScore
3.90
自引率
6.90%
发文量
481
审稿时长
6-12 weeks
期刊介绍: BMC Oral Health is an open access, peer-reviewed journal that considers articles on all aspects of the prevention, diagnosis and management of disorders of the mouth, teeth and gums, as well as related molecular genetics, pathophysiology, and epidemiology.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信