{"title":"Potential vision tester using Maxwellian view, small pupil, and different levels of wavefront correction with adaptive optics.","authors":"Vamsi Parimi, Ann E Elsner, Stephen A Burns, Thomas J Gast","doi":"10.1364/BOE.559475","DOIUrl":null,"url":null,"abstract":"<p><p>We demonstrate a potential vision tester (PVT) designed to study and improve the accuracy of visual acuity (VA) measurements in the aging eye. Key features include a high-resolution visual display presented in Maxwellian view, a 3 mm pupil to limit wavefront (WF) aberrations, a Hartmann Shack wavefront sensor to quantify the ocular aberrations, and a deformable mirror to correct optical aberrations. VA was measured using four alternative forced choices for a single black-on-white E stimulus in each trial, with three different levels of correction for the ocular aberrations. For normally sighted subjects, VA was not significantly better when higher-order aberrations beyond second order were corrected.</p>","PeriodicalId":8969,"journal":{"name":"Biomedical optics express","volume":"16 6","pages":"2528-2542"},"PeriodicalIF":3.2000,"publicationDate":"2025-05-30","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12265484/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Biomedical optics express","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1364/BOE.559475","RegionNum":2,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/1 0:00:00","PubModel":"eCollection","JCR":"Q2","JCRName":"BIOCHEMICAL RESEARCH METHODS","Score":null,"Total":0}
引用次数: 0
Abstract
We demonstrate a potential vision tester (PVT) designed to study and improve the accuracy of visual acuity (VA) measurements in the aging eye. Key features include a high-resolution visual display presented in Maxwellian view, a 3 mm pupil to limit wavefront (WF) aberrations, a Hartmann Shack wavefront sensor to quantify the ocular aberrations, and a deformable mirror to correct optical aberrations. VA was measured using four alternative forced choices for a single black-on-white E stimulus in each trial, with three different levels of correction for the ocular aberrations. For normally sighted subjects, VA was not significantly better when higher-order aberrations beyond second order were corrected.
期刊介绍:
The journal''s scope encompasses fundamental research, technology development, biomedical studies and clinical applications. BOEx focuses on the leading edge topics in the field, including:
Tissue optics and spectroscopy
Novel microscopies
Optical coherence tomography
Diffuse and fluorescence tomography
Photoacoustic and multimodal imaging
Molecular imaging and therapies
Nanophotonic biosensing
Optical biophysics/photobiology
Microfluidic optical devices
Vision research.