Comparison of osseodensification and standard drilling methods on implant stability quotient and insertion torque values of implants.

Journal of advanced periodontology & implant dentistry Pub Date : 2025-04-23 eCollection Date: 2025-06-01 DOI:10.34172/japid.025.3475
Omid Moghaddas, Vanda Banazadeh
{"title":"Comparison of osseodensification and standard drilling methods on implant stability quotient and insertion torque values of implants.","authors":"Omid Moghaddas, Vanda Banazadeh","doi":"10.34172/japid.025.3475","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>This study aimed to compare insertion torque (IT) and implant stability quotient (ISQ) values immediately and three months after surgery with standard drilling (SD) and osseodensification (OD) drilling methods.</p><p><strong>Methods: </strong>In this prospective study, 39 implants with the same diameter and length were placed in 21 patients using SD (23 implants) and OD (16 implants) methods in the posterior maxilla. The amounts of IT after surgery and ISQ after surgery and three months later were evaluated. The data were extracted and statistically analyzed with PASS2 software. The difference between IT and ISQ was determined by the two-way repeated-measures ANOVA at a significance level of 0.001.</p><p><strong>Results: </strong>Immediately after surgery, the amount of IT using the OD drilling method was 37% higher than the SD drilling (<i>P</i><0.001). ISQ values after surgery did not show a significant difference between SD and OD (<i>P</i>1<0.176). Three months after surgery, the ISQ values in both groups were not significantly different. ISQ values for all OD and SD group experimental parameters remained above the threshold value of 68. IT values showed a positive correlation with ISQ values at baseline.</p><p><strong>Conclusion: </strong>In the present study, the OD technique provided a higher IT rate after surgery compared to the SD method; however, no difference was seen between the two groups regarding ISQ value either after surgery or three months later.</p>","PeriodicalId":73584,"journal":{"name":"Journal of advanced periodontology & implant dentistry","volume":"17 2","pages":"59-64"},"PeriodicalIF":0.0000,"publicationDate":"2025-04-23","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12261070/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of advanced periodontology & implant dentistry","FirstCategoryId":"1085","ListUrlMain":"https://doi.org/10.34172/japid.025.3475","RegionNum":0,"RegionCategory":null,"ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/1 0:00:00","PubModel":"eCollection","JCR":"","JCRName":"","Score":null,"Total":0}
引用次数: 0

Abstract

Background: This study aimed to compare insertion torque (IT) and implant stability quotient (ISQ) values immediately and three months after surgery with standard drilling (SD) and osseodensification (OD) drilling methods.

Methods: In this prospective study, 39 implants with the same diameter and length were placed in 21 patients using SD (23 implants) and OD (16 implants) methods in the posterior maxilla. The amounts of IT after surgery and ISQ after surgery and three months later were evaluated. The data were extracted and statistically analyzed with PASS2 software. The difference between IT and ISQ was determined by the two-way repeated-measures ANOVA at a significance level of 0.001.

Results: Immediately after surgery, the amount of IT using the OD drilling method was 37% higher than the SD drilling (P<0.001). ISQ values after surgery did not show a significant difference between SD and OD (P1<0.176). Three months after surgery, the ISQ values in both groups were not significantly different. ISQ values for all OD and SD group experimental parameters remained above the threshold value of 68. IT values showed a positive correlation with ISQ values at baseline.

Conclusion: In the present study, the OD technique provided a higher IT rate after surgery compared to the SD method; however, no difference was seen between the two groups regarding ISQ value either after surgery or three months later.

骨化与标准钻孔方法对种植体稳定商及植入扭矩值的影响。
背景:本研究旨在比较标准钻孔(SD)和骨密度钻孔(OD)方法即刻和术后3个月的插入扭矩(IT)和种植体稳定商(ISQ)值。方法:采用SD法(23颗)和OD法(16颗)在21例患者的后上颌放置39颗直径和长度相同的种植体。评估术后IT水平和术后及3个月后ISQ水平。采用PASS2软件对数据进行提取和统计分析。IT和ISQ之间的差异通过双向重复测量方差分析确定,显著性水平为0.001。结果:术后即刻,使用OD钻孔法的IT量比SD钻孔法高37% (pp1)。结论:在本研究中,OD技术比SD方法提供更高的术后IT率;然而,两组在手术后或三个月后的ISQ值没有差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
CiteScore
0.60
自引率
0.00%
发文量
0
审稿时长
20 weeks
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信