Early outcomes of Myval™ Octacor transcatheter pulmonary valve implantation in dysfunctional right ventricular outflow tract conduits and pulmonary valve bioprostheses: a single-centre UK experience.

IF 0.9 4区 医学 Q4 CARDIAC & CARDIOVASCULAR SYSTEMS
Mohammed Kamal Badawy, Atul Kalantre, Marinos Kantzis
{"title":"Early outcomes of Myval™ Octacor transcatheter pulmonary valve implantation in dysfunctional right ventricular outflow tract conduits and pulmonary valve bioprostheses: a single-centre UK experience.","authors":"Mohammed Kamal Badawy, Atul Kalantre, Marinos Kantzis","doi":"10.1017/S1047951125100590","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Transcatheter pulmonary valve implantation has emerged as a minimally invasive and preferred therapeutic option for patients with dysfunction of previously repaired right ventricular outflow tracts. The Myval™ Octacor valve is a new device designed for this purpose, though limited reports exist regarding its use in the pulmonary position.</p><p><strong>Aims: </strong>To report the immediate and short-term outcomes of percutaneous pulmonary valve implantation using the Myval™ Octacor valve in patients with severe right ventricular-pulmonary artery conduit or pulmonary valve bioprosthesis dysfunction.</p><p><strong>Methods: </strong>This was a single-centre retrospective review of data obtained from case files.</p><p><strong>Results: </strong>The Myval™ Octacor valve was used in ten patients with a mean age of 34.5 ± 7.4 years. The median procedure duration and fluoroscopy time were 146 minutes and 30.5 minutes, respectively. The median Z-score for valves used was -0.5. The median right ventricular systolic pressure decreased from 68.5 mmHg pre-procedure to 33 mmHg post-procedure. The median peak instantaneous gradient across the right ventricular outflow tract or conduit decreased from 30 mmHg to 6.5 mmHg. There were no reported incidences of frame fracture, conduit rupture, device embolisation, or endocarditis.</p><p><strong>Conclusion: </strong>This is the first UK experience of using the new-generation Myval™ Octacor valve in percutaneous pulmonary valve implantation. The results demonstrate the valve's safety and clinical efficacy, with favourable outcomes in terms of procedural success, haemodynamic improvement, and echocardiographic findings.</p>","PeriodicalId":9435,"journal":{"name":"Cardiology in the Young","volume":" ","pages":"1-7"},"PeriodicalIF":0.9000,"publicationDate":"2025-07-16","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Cardiology in the Young","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1017/S1047951125100590","RegionNum":4,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q4","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Transcatheter pulmonary valve implantation has emerged as a minimally invasive and preferred therapeutic option for patients with dysfunction of previously repaired right ventricular outflow tracts. The Myval™ Octacor valve is a new device designed for this purpose, though limited reports exist regarding its use in the pulmonary position.

Aims: To report the immediate and short-term outcomes of percutaneous pulmonary valve implantation using the Myval™ Octacor valve in patients with severe right ventricular-pulmonary artery conduit or pulmonary valve bioprosthesis dysfunction.

Methods: This was a single-centre retrospective review of data obtained from case files.

Results: The Myval™ Octacor valve was used in ten patients with a mean age of 34.5 ± 7.4 years. The median procedure duration and fluoroscopy time were 146 minutes and 30.5 minutes, respectively. The median Z-score for valves used was -0.5. The median right ventricular systolic pressure decreased from 68.5 mmHg pre-procedure to 33 mmHg post-procedure. The median peak instantaneous gradient across the right ventricular outflow tract or conduit decreased from 30 mmHg to 6.5 mmHg. There were no reported incidences of frame fracture, conduit rupture, device embolisation, or endocarditis.

Conclusion: This is the first UK experience of using the new-generation Myval™ Octacor valve in percutaneous pulmonary valve implantation. The results demonstrate the valve's safety and clinical efficacy, with favourable outcomes in terms of procedural success, haemodynamic improvement, and echocardiographic findings.

Myval™Octacor经导管肺动脉瓣植入功能障碍右心室流出道导管和肺动脉瓣生物假体的早期结果:英国单中心经验
背景:经导管肺动脉瓣植入术已成为右室流出道修复功能障碍患者的微创首选治疗方案。Myval™八爪阀是为此目的而设计的一种新设备,但关于其在肺位的应用报道有限。目的:报告使用Myval™八口瓣膜经皮肺动脉瓣植入术治疗严重右心室-肺动脉导管或肺动脉瓣生物假体功能障碍患者的近期和短期结果。方法:这是一项单中心回顾性研究,从病例档案中获得数据。结果:10例患者使用Myval™八口瓣膜,平均年龄为34.5±7.4岁。中位手术时间和透视时间分别为146分钟和30.5分钟。所用瓣膜的中位数z得分为-0.5。右心室中位收缩压从术前的68.5 mmHg降至术后的33 mmHg。右心室流出道或导管瞬时梯度中位峰从30mmhg降至6.5 mmHg。没有框架骨折、导管破裂、器械栓塞或心内膜炎的报道。结论:这是英国首次使用新一代Myval™八瓣经皮肺动脉瓣植入术。结果证明了该瓣膜的安全性和临床有效性,在手术成功、血流动力学改善和超声心动图检查方面都有良好的结果。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Cardiology in the Young
Cardiology in the Young 医学-小儿科
CiteScore
1.70
自引率
10.00%
发文量
715
审稿时长
4-8 weeks
期刊介绍: Cardiology in the Young is devoted to cardiovascular issues affecting the young, and the older patient suffering the sequels of congenital heart disease, or other cardiac diseases acquired in childhood. The journal serves the interests of all professionals concerned with these topics. By design, the journal is international and multidisciplinary in its approach, and members of the editorial board take an active role in the its mission, helping to make it the essential journal in paediatric cardiology. All aspects of paediatric cardiology are covered within the journal. The content includes original articles, brief reports, editorials, reviews, and papers devoted to continuing professional development.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信