Direct determination of rare earth elements in atmospheric precipitation using a membrane desolvation ICP-MS/MS with N2O as the reaction gas

IF 4.6 3区 化学 Q2 CHEMISTRY, MULTIDISCIPLINARY
RSC Advances Pub Date : 2025-07-15 DOI:10.1039/D5RA02544C
Jiang-yi Zhang, Wen-jing Liu, Di Liu, Guang-liang Wu and Zhi-fang Xu
{"title":"Direct determination of rare earth elements in atmospheric precipitation using a membrane desolvation ICP-MS/MS with N2O as the reaction gas","authors":"Jiang-yi Zhang, Wen-jing Liu, Di Liu, Guang-liang Wu and Zhi-fang Xu","doi":"10.1039/D5RA02544C","DOIUrl":null,"url":null,"abstract":"<p >Analyzing rare earth elements (REEs) in atmospheric precipitation can reveal their sources and migration patterns. However, their direct determination in atmospheric precipitation using ICP-MS/MS remains challenging owing to low (sub-ng L<small><sup>−1</sup></small>) levels and mass spectral interference. This study established a reliable ICP-MS/MS method using a membrane desolvation system to enhance the sensitivity of REEs detections and employing N<small><sub>2</sub></small>O as the reaction gas to eliminate spectral interference for the direct measurement of REEs in atmospheric precipitation. The production rates of REE monoxides were significantly enhanced when using N<small><sub>2</sub></small>O as the reaction gas instead of O<small><sub>2</sub></small>. In particular, the yield of EuO<small><sup>+</sup></small> increased to 64.9%, while that of YbO<small><sup>+</sup></small> increased to 39.5%. A regular 10% signal suppression of REE<small><sup>+</sup></small> was observed in the presence of matrix using membrane desolvation and employing <small><sup>185</sup></small>Re as an internal standard effectively improved the results by &gt;98%. The instrumental detection limits of the proposed method ranged from 0.001 ng L<small><sup>−1</sup></small> for Lu to 0.022 ng L<small><sup>−1</sup></small> for Nd. The results for REEs in the certified reference material (SLRS-6) at a 1 : 10 dilution was consistent with the values reported in the literature. Thus, the proposed method was employed to analyze atmospheric precipitation samples. The accuracy of the results demonstrated that this method has the potential for routinely measuring sub ng L<small><sup>−1</sup></small> levels of REEs in freshwater samples, offering advantages regarding sample throughput and reduced handling.</p>","PeriodicalId":102,"journal":{"name":"RSC Advances","volume":" 30","pages":" 24844-24850"},"PeriodicalIF":4.6000,"publicationDate":"2025-07-15","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://pubs.rsc.org/en/content/articlepdf/2025/ra/d5ra02544c?page=search","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"RSC Advances","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ra/d5ra02544c","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, MULTIDISCIPLINARY","Score":null,"Total":0}
引用次数: 0

Abstract

Analyzing rare earth elements (REEs) in atmospheric precipitation can reveal their sources and migration patterns. However, their direct determination in atmospheric precipitation using ICP-MS/MS remains challenging owing to low (sub-ng L−1) levels and mass spectral interference. This study established a reliable ICP-MS/MS method using a membrane desolvation system to enhance the sensitivity of REEs detections and employing N2O as the reaction gas to eliminate spectral interference for the direct measurement of REEs in atmospheric precipitation. The production rates of REE monoxides were significantly enhanced when using N2O as the reaction gas instead of O2. In particular, the yield of EuO+ increased to 64.9%, while that of YbO+ increased to 39.5%. A regular 10% signal suppression of REE+ was observed in the presence of matrix using membrane desolvation and employing 185Re as an internal standard effectively improved the results by >98%. The instrumental detection limits of the proposed method ranged from 0.001 ng L−1 for Lu to 0.022 ng L−1 for Nd. The results for REEs in the certified reference material (SLRS-6) at a 1 : 10 dilution was consistent with the values reported in the literature. Thus, the proposed method was employed to analyze atmospheric precipitation samples. The accuracy of the results demonstrated that this method has the potential for routinely measuring sub ng L−1 levels of REEs in freshwater samples, offering advantages regarding sample throughput and reduced handling.

Abstract Image

以N2O为反应气体的膜脱溶ICP-MS/MS直接测定大气降水中的稀土元素
分析大气降水中的稀土元素,可以揭示其来源和迁移模式。然而,由于低(亚ng L−1)水平和质谱干扰,使用ICP-MS/MS在大气降水中直接测定它们仍然具有挑战性。本研究建立了一种可靠的ICP-MS/MS方法,采用膜脱溶体系提高稀土元素检测的灵敏度,以N2O为反应气体消除光谱干扰,用于大气降水中稀土元素的直接测量。用N2O代替O2作为反应气体,稀土氧化物的产率显著提高。其中EuO+的收率提高到64.9%,YbO+的收率提高到39.5%。在基质存在的情况下,通过膜脱溶和185Re作为内标,观察到REE+有10%的规律性信号抑制,有效地将结果提高了98%。该方法的仪器检出限为0.001 ng L−1 ~ 0.022 ng L−1。经鉴定的标准物质(SLRS-6)在1:10稀释下的稀土元素的测定结果与文献报道的值一致。因此,采用该方法对大气降水样品进行了分析。结果的准确性表明,该方法具有常规测量淡水样品中亚ng L−1稀土含量的潜力,在样品通量和减少处理方面具有优势。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
RSC Advances
RSC Advances chemical sciences-
CiteScore
7.50
自引率
2.60%
发文量
3116
审稿时长
1.6 months
期刊介绍: An international, peer-reviewed journal covering all of the chemical sciences, including multidisciplinary and emerging areas. RSC Advances is a gold open access journal allowing researchers free access to research articles, and offering an affordable open access publishing option for authors around the world.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信