Water starvation phenomena in a segmented along the channel PEM water electrolysis cell

IF 7.9 2区 工程技术 Q1 CHEMISTRY, PHYSICAL
Niklas Hensle , Thomas Lickert , Nico Winterholler , Tom Smolinka , André Weber
{"title":"Water starvation phenomena in a segmented along the channel PEM water electrolysis cell","authors":"Niklas Hensle ,&nbsp;Thomas Lickert ,&nbsp;Nico Winterholler ,&nbsp;Tom Smolinka ,&nbsp;André Weber","doi":"10.1016/j.jpowsour.2025.237865","DOIUrl":null,"url":null,"abstract":"<div><div>Proton exchange membrane water electrolyzers are typically operated with high water stoichiometry since the water, as a reactant, is also used as cooling agent for heat management. Water starvation phenomena are therefore not a pressing issue. However, in large industrial cell designs with challenging flow distribution, some areas of the cell may not be properly supplied with water.</div><div>This study investigates water starvation in a segmented test cell with 30 cm long flow field channels. By varying the water flow rate close to the stoichiometric level, local membrane dry-out and mass transport issues are investigated. To achieve this, the distribution of current density, temperature, and impedance are analyzed up to 5 A∙cm<sup>−2</sup> mean cell current density. Distribution of Relaxation Time is used to analyze the local impedance.</div><div>Our findings reveal that undersupply of water drastically affects the high frequency resistance coupled with increasing low-frequency capacitive features of the impedance, which we refer to as membrane dry-out due to mass transport limitations. However, mass transport issues, without a significant influence on membrane resistance, seem not to be relevant. By varying the gas pressure, membrane dry-out effects can be reduced which emphasizes the importance of oxygen removal at the anode.</div></div>","PeriodicalId":377,"journal":{"name":"Journal of Power Sources","volume":"654 ","pages":"Article 237865"},"PeriodicalIF":7.9000,"publicationDate":"2025-07-12","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Journal of Power Sources","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S037877532501701X","RegionNum":2,"RegionCategory":"工程技术","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CHEMISTRY, PHYSICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Proton exchange membrane water electrolyzers are typically operated with high water stoichiometry since the water, as a reactant, is also used as cooling agent for heat management. Water starvation phenomena are therefore not a pressing issue. However, in large industrial cell designs with challenging flow distribution, some areas of the cell may not be properly supplied with water.
This study investigates water starvation in a segmented test cell with 30 cm long flow field channels. By varying the water flow rate close to the stoichiometric level, local membrane dry-out and mass transport issues are investigated. To achieve this, the distribution of current density, temperature, and impedance are analyzed up to 5 A∙cm−2 mean cell current density. Distribution of Relaxation Time is used to analyze the local impedance.
Our findings reveal that undersupply of water drastically affects the high frequency resistance coupled with increasing low-frequency capacitive features of the impedance, which we refer to as membrane dry-out due to mass transport limitations. However, mass transport issues, without a significant influence on membrane resistance, seem not to be relevant. By varying the gas pressure, membrane dry-out effects can be reduced which emphasizes the importance of oxygen removal at the anode.
一种分段沿通道PEM的水电解池的缺水现象
质子交换膜水电解槽通常使用高水化学计量,因为水作为反应物也用作热管理的冷却剂。因此,缺水现象不是一个紧迫的问题。然而,在具有挑战性的流动分布的大型工业电池设计中,电池的某些区域可能没有适当的供水。本研究在一个具有30厘米长流场通道的分段试验细胞中研究了水饥饿。通过改变接近化学计量水平的水流速率,研究了局部膜干燥和质量运输问题。为了实现这一点,电流密度、温度和阻抗的分布被分析到5 A∙cm−2的平均电池电流密度。利用松弛时间的分布来分析局部阻抗。我们的研究结果表明,水供应不足极大地影响了高频电阻,加上阻抗的低频电容特性增加,我们将其称为由于质量传输限制而导致的膜干。然而,质量传输问题,没有显著影响膜阻力,似乎不相关。通过改变气体压力,可以减少膜干效应,这强调了阳极除氧的重要性。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Journal of Power Sources
Journal of Power Sources 工程技术-电化学
CiteScore
16.40
自引率
6.50%
发文量
1249
审稿时长
36 days
期刊介绍: The Journal of Power Sources is a publication catering to researchers and technologists interested in various aspects of the science, technology, and applications of electrochemical power sources. It covers original research and reviews on primary and secondary batteries, fuel cells, supercapacitors, and photo-electrochemical cells. Topics considered include the research, development and applications of nanomaterials and novel componentry for these devices. Examples of applications of these electrochemical power sources include: • Portable electronics • Electric and Hybrid Electric Vehicles • Uninterruptible Power Supply (UPS) systems • Storage of renewable energy • Satellites and deep space probes • Boats and ships, drones and aircrafts • Wearable energy storage systems
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信