The influence of milling protocols on the fatigue behavior of different CAD-CAM materials

IF 4.6 1区 医学 Q1 DENTISTRY, ORAL SURGERY & MEDICINE
Rafaela Oliveira Pilecco , Maria Gabriela Packaeser , João Paulo Mendes Tribst , Carlos M. Serrano , Luiz Felipe Valandro , Cornelis Johannes Kleverlaan , Gabriel Kalil Rocha Pereira
{"title":"The influence of milling protocols on the fatigue behavior of different CAD-CAM materials","authors":"Rafaela Oliveira Pilecco ,&nbsp;Maria Gabriela Packaeser ,&nbsp;João Paulo Mendes Tribst ,&nbsp;Carlos M. Serrano ,&nbsp;Luiz Felipe Valandro ,&nbsp;Cornelis Johannes Kleverlaan ,&nbsp;Gabriel Kalil Rocha Pereira","doi":"10.1016/j.dental.2025.07.001","DOIUrl":null,"url":null,"abstract":"<div><h3>Objectives</h3><div>To assess the fatigue behavior of a glass-ceramic and a resin composite milled with two different protocols in a 4-axis milling machine.</div></div><div><h3>Methods</h3><div>Lithium disilicate and resin composite crowns were milled using fine or extra fine mode in a 4-axis machine (n= 15). A full crown molar fiber-reinforced resin epoxy die was scanned and used as substrate. Respective surface treatments were applied, and the restorations were bonded with dual resin cement. Cyclic fatigue test was carried out (20 Hz, initial load 400 N, step size 50 N up to 1500 N, then increased to 100 N with 10,000 cycles per step) to assess the fatigue behavior up to the first crack. All specimens were submitted to a fracture load test until catastrophic fracture. Finite element analysis, topography, and fractography were also conducted. Bur wear was analyzed. Kaplan-Meier and two-way ANOVA tests were carried out to analyze fatigue behavior and fracture load, respectively.</div></div><div><h3>Results</h3><div>No significant difference in fatigue behavior was observed between the milling modes for both materials. Resin composite presented a higher survival rate until crack than lithium disilicate. No difference was found in fracture load among the groups. Extra fine milling mode promotes higher bur wear compared to the fine mode. Noticeable contact damage was observed in both materials.</div></div><div><h3>Significance</h3><div>Resin composite crowns exhibit superior fatigue behavior until crack detection compared to lithium disilicate, regardless of the milling mode. No significant difference in catastrophic fracture load was observed between the milling modes or the restorative materials.</div></div>","PeriodicalId":298,"journal":{"name":"Dental Materials","volume":"41 9","pages":"Pages 1179-1187"},"PeriodicalIF":4.6000,"publicationDate":"2025-07-08","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Dental Materials","FirstCategoryId":"5","ListUrlMain":"https://www.sciencedirect.com/science/article/pii/S0109564125006979","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"DENTISTRY, ORAL SURGERY & MEDICINE","Score":null,"Total":0}
引用次数: 0

Abstract

Objectives

To assess the fatigue behavior of a glass-ceramic and a resin composite milled with two different protocols in a 4-axis milling machine.

Methods

Lithium disilicate and resin composite crowns were milled using fine or extra fine mode in a 4-axis machine (n= 15). A full crown molar fiber-reinforced resin epoxy die was scanned and used as substrate. Respective surface treatments were applied, and the restorations were bonded with dual resin cement. Cyclic fatigue test was carried out (20 Hz, initial load 400 N, step size 50 N up to 1500 N, then increased to 100 N with 10,000 cycles per step) to assess the fatigue behavior up to the first crack. All specimens were submitted to a fracture load test until catastrophic fracture. Finite element analysis, topography, and fractography were also conducted. Bur wear was analyzed. Kaplan-Meier and two-way ANOVA tests were carried out to analyze fatigue behavior and fracture load, respectively.

Results

No significant difference in fatigue behavior was observed between the milling modes for both materials. Resin composite presented a higher survival rate until crack than lithium disilicate. No difference was found in fracture load among the groups. Extra fine milling mode promotes higher bur wear compared to the fine mode. Noticeable contact damage was observed in both materials.

Significance

Resin composite crowns exhibit superior fatigue behavior until crack detection compared to lithium disilicate, regardless of the milling mode. No significant difference in catastrophic fracture load was observed between the milling modes or the restorative materials.
铣削工艺对不同CAD-CAM材料疲劳行为的影响。
目的:评估玻璃陶瓷和树脂复合材料在四轴铣床上以两种不同的方案铣削的疲劳行为。方法:二硅酸锂和树脂复合冠在四轴铣床上采用精细或超精细模式铣削(n= 15)。扫描了全冠磨牙纤维增强树脂环氧树脂模具作为基板。采用不同的表面处理方法,修复体采用双树脂胶粘剂粘接。进行了循环疲劳试验(20 Hz,初始载荷400 N,步长50 N至1500 N,然后增加到100 N,每步循环10,000次),以评估疲劳行为直到第一个裂纹。所有试件均进行断裂载荷试验,直至发生突变断裂。还进行了有限元分析、形貌分析和断口分析。但磨损进行了分析。Kaplan-Meier检验和双向方差分析分别分析了疲劳行为和断裂载荷。结果:两种材料的铣削方式在疲劳行为上没有显著差异。树脂复合材料在开裂前的存活率高于二硅酸锂。各组间骨折负荷无明显差异。与精细铣削模式相比,超精细铣削模式促进更高的磨损。在两种材料中都观察到明显的接触损伤。意义:与二硅酸锂相比,无论铣削方式如何,树脂复合冠在裂纹检测前都表现出优越的疲劳性能。在铣削方式和修复材料之间,突变断裂载荷没有显著差异。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Dental Materials
Dental Materials 工程技术-材料科学:生物材料
CiteScore
9.80
自引率
10.00%
发文量
290
审稿时长
67 days
期刊介绍: Dental Materials publishes original research, review articles, and short communications. Academy of Dental Materials members click here to register for free access to Dental Materials online. The principal aim of Dental Materials is to promote rapid communication of scientific information between academia, industry, and the dental practitioner. Original Manuscripts on clinical and laboratory research of basic and applied character which focus on the properties or performance of dental materials or the reaction of host tissues to materials are given priority publication. Other acceptable topics include application technology in clinical dentistry and dental laboratory technology. Comprehensive reviews and editorial commentaries on pertinent subjects will be considered.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信