Akash Jain, John Jose, Matteo Montorfano, Henrik Nissen, Pedro Martin, Ashok Seth, Kresimir Stambuk, Gunasekaran Sengottuvelu, Mussayev Abdurashid, Mario García-Gómez, Clara Fernandez-Cordón, Marcelo Rodriguez, Mathias D Jorgensen, Alberto Campo, Ana Serrador, Silvia Vallinas-Hernandez, Manuel Carrasco-Moraleja, Alberto San Román, Ignacio J Amat-Santos
{"title":"Four-year durability of the Myval balloon-expandable transcatheter aortic valve.","authors":"Akash Jain, John Jose, Matteo Montorfano, Henrik Nissen, Pedro Martin, Ashok Seth, Kresimir Stambuk, Gunasekaran Sengottuvelu, Mussayev Abdurashid, Mario García-Gómez, Clara Fernandez-Cordón, Marcelo Rodriguez, Mathias D Jorgensen, Alberto Campo, Ana Serrador, Silvia Vallinas-Hernandez, Manuel Carrasco-Moraleja, Alberto San Román, Ignacio J Amat-Santos","doi":"10.4244/EIJ-D-24-01112","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>The Myval series is the first commercially available balloon-expandable transcatheter aortic valve implantation (TAVI) system designed as an alternative to the SAPIEN series. The LANDMARK trial recently demonstrated its non-inferiority compared to contemporary systems. However, the long-term durability of the Myval series remains unknown.</p><p><strong>Aims: </strong>We aimed to evaluate the 4-year durability of the Myval series using Valve Academic Research Consortium (VARC)-3-defined endpoints.</p><p><strong>Methods: </strong>We carried out a multicentre ambispective study of patients with severe aortic stenosis who underwent TAVI with the Myval series between December 2017 and April 2020. Baseline characteristics were prospectively recorded in a dedicated database. Clinical and echocardiographic follow-up was performed at 4 years. Outcomes included haemodynamic valve deterioration (HVD), bioprosthetic valve failure (BVF), and patient-prosthesis mismatch (PPM) as defined by the VARC-3 criteria, assessed at a central echocardiography laboratory.</p><p><strong>Results: </strong>A total of 366 patients from 9 institutions were included, all of whom completed 4-year follow-up or were followed up until death. The 4-year survival rate was 81.8%, with residual ≥moderate aortic regurgitation observed in 9.2% of patients. BVF criterion 1 (symptomatic valve failure) occurred in 3.3%, while no cases of BVF criteria 2 or 3 were reported. Stage 2 HVD was observed in 9.7% of patients and stage 3 HVD in 0.7% at 4 years. Moderate and severe PPM were identified in 3.6% and 2.1% of patients at 1 year, respectively.</p><p><strong>Conclusions: </strong>In a real-world cohort, 4-year outcomes with the balloon-expandable Myval series demonstrated acceptable valve durability, low haemodynamic deterioration, and comparable performance to contemporary TAVI systems.</p>","PeriodicalId":54378,"journal":{"name":"Eurointervention","volume":"21 13","pages":"e758-e765"},"PeriodicalIF":9.5000,"publicationDate":"2025-07-07","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"https://www.ncbi.nlm.nih.gov/pmc/articles/PMC12207338/pdf/","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Eurointervention","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.4244/EIJ-D-24-01112","RegionNum":1,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q1","JCRName":"CARDIAC & CARDIOVASCULAR SYSTEMS","Score":null,"Total":0}
引用次数: 0
Abstract
Background: The Myval series is the first commercially available balloon-expandable transcatheter aortic valve implantation (TAVI) system designed as an alternative to the SAPIEN series. The LANDMARK trial recently demonstrated its non-inferiority compared to contemporary systems. However, the long-term durability of the Myval series remains unknown.
Aims: We aimed to evaluate the 4-year durability of the Myval series using Valve Academic Research Consortium (VARC)-3-defined endpoints.
Methods: We carried out a multicentre ambispective study of patients with severe aortic stenosis who underwent TAVI with the Myval series between December 2017 and April 2020. Baseline characteristics were prospectively recorded in a dedicated database. Clinical and echocardiographic follow-up was performed at 4 years. Outcomes included haemodynamic valve deterioration (HVD), bioprosthetic valve failure (BVF), and patient-prosthesis mismatch (PPM) as defined by the VARC-3 criteria, assessed at a central echocardiography laboratory.
Results: A total of 366 patients from 9 institutions were included, all of whom completed 4-year follow-up or were followed up until death. The 4-year survival rate was 81.8%, with residual ≥moderate aortic regurgitation observed in 9.2% of patients. BVF criterion 1 (symptomatic valve failure) occurred in 3.3%, while no cases of BVF criteria 2 or 3 were reported. Stage 2 HVD was observed in 9.7% of patients and stage 3 HVD in 0.7% at 4 years. Moderate and severe PPM were identified in 3.6% and 2.1% of patients at 1 year, respectively.
Conclusions: In a real-world cohort, 4-year outcomes with the balloon-expandable Myval series demonstrated acceptable valve durability, low haemodynamic deterioration, and comparable performance to contemporary TAVI systems.
期刊介绍:
EuroIntervention Journal is an international, English language, peer-reviewed journal whose aim is to create a community of high quality research and education in the field of percutaneous and surgical cardiovascular interventions.