A polypyrrole-coated GCE sensor for sensitive detection of 5-fluorouracil via molecular imprinting†

IF 2.6 3区 化学 Q2 CHEMISTRY, ANALYTICAL
Manjeet Harijan, Akriti Srivastava and Meenakshi Singh
{"title":"A polypyrrole-coated GCE sensor for sensitive detection of 5-fluorouracil via molecular imprinting†","authors":"Manjeet Harijan, Akriti Srivastava and Meenakshi Singh","doi":"10.1039/D5AY00345H","DOIUrl":null,"url":null,"abstract":"<p >Cytotoxic drug 5-fluorouracil (5-FU) is a fluorine derivative of uracil; it is one of the most significant medications used to treat cancers of the stomach, breast, colon, pancreas, and cervical regions. Here, a reliable, rapid, highly sensitive and selective method is proposed for determining 5-FU in real samples. In this study, a molecularly imprinted polymer (MIP) based electrochemical sensor is designed for the sensitive and selective determination of 5-FU. The MIP was developed by the electropolymerization of a pyrrole thin film around template molecules (5-FU) on a glassy carbon electrode (GCE). The sensor was characterized after each stage of fabrication using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The MIP sensor exhibited a wide linear range for determining 5-FU from 2–42 μM. The developed sensor achieved a limit of detection (LOD) and limit of quantification (LOQ) of 0.605 μM and 1.834 μM, respectively. The applicability of the proposed sensor was examined for 5-FU determination in real samples. The MIP sensor exhibited excellent selectivity, repeatability, stability, and commercialization potential for 5-FU detection. Furthermore, the proposed method offers significant advantages over existing electrochemical techniques for 5-FU detection. This method provides single-step preparation alongside simple template molecule removal by cyclic voltammetry scans and does not need any extracting solvents.</p>","PeriodicalId":64,"journal":{"name":"Analytical Methods","volume":" 28","pages":" 5961-5972"},"PeriodicalIF":2.6000,"publicationDate":"2025-06-26","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Analytical Methods","FirstCategoryId":"92","ListUrlMain":"https://pubs.rsc.org/en/content/articlelanding/2025/ay/d5ay00345h","RegionNum":3,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"","PubModel":"","JCR":"Q2","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0

Abstract

Cytotoxic drug 5-fluorouracil (5-FU) is a fluorine derivative of uracil; it is one of the most significant medications used to treat cancers of the stomach, breast, colon, pancreas, and cervical regions. Here, a reliable, rapid, highly sensitive and selective method is proposed for determining 5-FU in real samples. In this study, a molecularly imprinted polymer (MIP) based electrochemical sensor is designed for the sensitive and selective determination of 5-FU. The MIP was developed by the electropolymerization of a pyrrole thin film around template molecules (5-FU) on a glassy carbon electrode (GCE). The sensor was characterized after each stage of fabrication using cyclic voltammetry (CV), differential pulse voltammetry (DPV), and electrochemical impedance spectroscopy (EIS). The MIP sensor exhibited a wide linear range for determining 5-FU from 2–42 μM. The developed sensor achieved a limit of detection (LOD) and limit of quantification (LOQ) of 0.605 μM and 1.834 μM, respectively. The applicability of the proposed sensor was examined for 5-FU determination in real samples. The MIP sensor exhibited excellent selectivity, repeatability, stability, and commercialization potential for 5-FU detection. Furthermore, the proposed method offers significant advantages over existing electrochemical techniques for 5-FU detection. This method provides single-step preparation alongside simple template molecule removal by cyclic voltammetry scans and does not need any extracting solvents.

Abstract Image

分子印迹法检测5-氟尿嘧啶的聚吡咯包被GCE传感器。
细胞毒性药物5-氟尿嘧啶(5-FU)是尿嘧啶的氟衍生物;它是用于治疗胃癌、乳腺癌、结肠癌、胰腺癌和宫颈癌的最重要的药物之一。本文提出了一种可靠、快速、高灵敏度和选择性的测定实际样品中5-FU的方法。本研究设计了一种基于分子印迹聚合物(MIP)的电化学传感器,用于灵敏、选择性地测定5-FU。MIP是在玻璃碳电极(GCE)上通过电聚合在模板分子(5-FU)周围形成吡咯薄膜而制备的。利用循环伏安法(CV)、差分脉冲伏安法(DPV)和电化学阻抗谱法(EIS)对传感器制造的各个阶段进行了表征。MIP传感器在2 ~ 42 μM范围内具有较宽的线性范围。该传感器的检测限和定量限分别为0.605 μM和1.834 μM。对所提出的传感器在实际样品中测定5-FU的适用性进行了检验。MIP传感器在5-FU检测中表现出优异的选择性、可重复性、稳定性和商业化潜力。此外,与现有的电化学技术相比,该方法具有显著的优势。该方法通过循环伏安扫描提供单步制备和简单的模板分子去除,不需要任何提取溶剂。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Analytical Methods
Analytical Methods CHEMISTRY, ANALYTICAL-FOOD SCIENCE & TECHNOLOGY
CiteScore
5.10
自引率
3.20%
发文量
569
审稿时长
1.8 months
期刊介绍: Early applied demonstrations of new analytical methods with clear societal impact
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信