Utility of cine clips of the spermatic cord in the diagnosis of testicular torsion in the pediatric population.

IF 2.3 3区 医学 Q2 PEDIATRICS
Pediatric Radiology Pub Date : 2025-08-01 Epub Date: 2025-07-04 DOI:10.1007/s00247-025-06312-4
Cassandra Sams, Eleanor DiBiasio, Rama Ayyala, Grayson Baird, Michael Furman, Alison Hart, Thaddeus Herliczek, David Swenson
{"title":"Utility of cine clips of the spermatic cord in the diagnosis of testicular torsion in the pediatric population.","authors":"Cassandra Sams, Eleanor DiBiasio, Rama Ayyala, Grayson Baird, Michael Furman, Alison Hart, Thaddeus Herliczek, David Swenson","doi":"10.1007/s00247-025-06312-4","DOIUrl":null,"url":null,"abstract":"<p><strong>Background: </strong>Indirect evidence of testicular torsion, namely lack of blood flow, has been a mainstay in the imaging diagnosis of testicular torsion. Recently, attention has been given to the etiology of testicular torsion, namely the twisted vascular pedicle. However, no study to date has demonstrated the diagnostic yield of inclusion of cine clips of the spermatic cord in identifying this twist.</p><p><strong>Objective: </strong>This study seeks to demonstrate whether the inclusion of cine clips of the spermatic cord impacts the diagnostic performance of ultrasound in diagnosing testicular torsion.</p><p><strong>Materials and methods: </strong>This study employed a multi-reader multi-case complete and balanced block cross-over design to assess the diagnostic performance of ultrasound, specifically the impact of cine clips of the spermatic cord. From 1/1/2015 to 12/31/2017, ultrasounds of 156 patients presenting with acute onset of unilateral scrotal pain were reviewed by five pediatric radiologists. Within this data set were 52 cases of surgically confirmed testicular torsion, 52 cases that were abnormal but without testicular torsion, and 52 normal exams. The data set was reviewed twice; initially, static images alone were reviewed. After a period of at least 2 weeks, the data set was again reviewed with the inclusion of cine clips of the spermatic cord. A questionnaire was answered after each review that elicited the radiologist's final diagnosis. Sensitivity and specificity between imaging features were estimated using generalized linear mixed modeling with the GLIMMIX procedure.</p><p><strong>Results: </strong>With the inclusion of cine clips of the spermatic cord, the sensitivity in diagnosing testicular torsion increased from 88.8% (95%CI 78.1-94.6%) to 98.5% (95%CI 96.0-99.5%) (P < 0.0001) with no statistically significant change to specificity 98.4% (95%CI 95.9-99.4%) to 97.0% (95%CI 94.9-98.3%) (P = 0.61).</p><p><strong>Conclusion: </strong>This study provides compelling evidence to consider cine clips of the spermatic cord as part of a standard ultrasound approach for the work-up of testicular pain due to the nearly 10% increase in sensitivity in diagnosing testicular torsion with their inclusion.</p>","PeriodicalId":19755,"journal":{"name":"Pediatric Radiology","volume":" ","pages":"1857-1863"},"PeriodicalIF":2.3000,"publicationDate":"2025-08-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Pediatric Radiology","FirstCategoryId":"3","ListUrlMain":"https://doi.org/10.1007/s00247-025-06312-4","RegionNum":3,"RegionCategory":"医学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/7/4 0:00:00","PubModel":"Epub","JCR":"Q2","JCRName":"PEDIATRICS","Score":null,"Total":0}
引用次数: 0

Abstract

Background: Indirect evidence of testicular torsion, namely lack of blood flow, has been a mainstay in the imaging diagnosis of testicular torsion. Recently, attention has been given to the etiology of testicular torsion, namely the twisted vascular pedicle. However, no study to date has demonstrated the diagnostic yield of inclusion of cine clips of the spermatic cord in identifying this twist.

Objective: This study seeks to demonstrate whether the inclusion of cine clips of the spermatic cord impacts the diagnostic performance of ultrasound in diagnosing testicular torsion.

Materials and methods: This study employed a multi-reader multi-case complete and balanced block cross-over design to assess the diagnostic performance of ultrasound, specifically the impact of cine clips of the spermatic cord. From 1/1/2015 to 12/31/2017, ultrasounds of 156 patients presenting with acute onset of unilateral scrotal pain were reviewed by five pediatric radiologists. Within this data set were 52 cases of surgically confirmed testicular torsion, 52 cases that were abnormal but without testicular torsion, and 52 normal exams. The data set was reviewed twice; initially, static images alone were reviewed. After a period of at least 2 weeks, the data set was again reviewed with the inclusion of cine clips of the spermatic cord. A questionnaire was answered after each review that elicited the radiologist's final diagnosis. Sensitivity and specificity between imaging features were estimated using generalized linear mixed modeling with the GLIMMIX procedure.

Results: With the inclusion of cine clips of the spermatic cord, the sensitivity in diagnosing testicular torsion increased from 88.8% (95%CI 78.1-94.6%) to 98.5% (95%CI 96.0-99.5%) (P < 0.0001) with no statistically significant change to specificity 98.4% (95%CI 95.9-99.4%) to 97.0% (95%CI 94.9-98.3%) (P = 0.61).

Conclusion: This study provides compelling evidence to consider cine clips of the spermatic cord as part of a standard ultrasound approach for the work-up of testicular pain due to the nearly 10% increase in sensitivity in diagnosing testicular torsion with their inclusion.

精索电影剪辑在小儿睾丸扭转诊断中的应用。
背景:睾丸扭转的间接证据,即缺乏血流,已成为睾丸扭转影像学诊断的主要依据。近年来,人们开始关注睾丸扭转的病因,即血管蒂扭曲。然而,到目前为止,还没有研究证明包括精索的电影剪辑在识别这种扭曲的诊断产量。目的:探讨精索电影剪辑是否会影响超声诊断睾丸扭转的诊断效果。材料与方法:本研究采用多读卡器多病例完整平衡的块交叉设计,评估超声诊断性能,特别是精索电影剪辑的影响。从2015年1月1日至2017年12月31日,5名儿科放射科医生对156例急性发作的单侧阴囊疼痛患者的超声检查进行了回顾。在该数据集中,52例手术证实睾丸扭转,52例异常但无睾丸扭转,52例检查正常。对数据集进行了两次审查;最初,只审查静态图像。至少2周后,再次回顾数据集,包括精索的电影片段。每次检查后都要回答一份问卷,得出放射科医生的最终诊断。使用广义线性混合建模和GLIMMIX程序估计成像特征之间的敏感性和特异性。结果:随着精索电影夹的纳入,诊断睾丸扭转的灵敏度从88.8% (95%CI 78.1-94.6%)提高到98.5% (95%CI 96.6 -99.5%) (P)。结论:精索电影夹的纳入诊断睾丸扭转的灵敏度提高了近10%,本研究提供了强有力的证据,可以考虑将其作为睾丸疼痛检查的标准超声检查的一部分。
本文章由计算机程序翻译,如有差异,请以英文原文为准。
求助全文
约1分钟内获得全文 求助全文
来源期刊
Pediatric Radiology
Pediatric Radiology 医学-核医学
CiteScore
4.40
自引率
17.40%
发文量
300
审稿时长
3-6 weeks
期刊介绍: Official Journal of the European Society of Pediatric Radiology, the Society for Pediatric Radiology and the Asian and Oceanic Society for Pediatric Radiology Pediatric Radiology informs its readers of new findings and progress in all areas of pediatric imaging and in related fields. This is achieved by a blend of original papers, complemented by reviews that set out the present state of knowledge in a particular area of the specialty or summarize specific topics in which discussion has led to clear conclusions. Advances in technology, methodology, apparatus and auxiliary equipment are presented, and modifications of standard techniques are described. Manuscripts submitted for publication must contain a statement to the effect that all human studies have been reviewed by the appropriate ethics committee and have therefore been performed in accordance with the ethical standards laid down in an appropriate version of the 1964 Declaration of Helsinki. It should also be stated clearly in the text that all persons gave their informed consent prior to their inclusion in the study. Details that might disclose the identity of the subjects under study should be omitted.
×
引用
GB/T 7714-2015
复制
MLA
复制
APA
复制
导出至
BibTeX EndNote RefMan NoteFirst NoteExpress
×
提示
您的信息不完整,为了账户安全,请先补充。
现在去补充
×
提示
您因"违规操作"
具体请查看互助需知
我知道了
×
提示
确定
请完成安全验证×
copy
已复制链接
快去分享给好友吧!
我知道了
右上角分享
点击右上角分享
0
联系我们:info@booksci.cn Book学术提供免费学术资源搜索服务,方便国内外学者检索中英文文献。致力于提供最便捷和优质的服务体验。 Copyright © 2023 布克学术 All rights reserved.
京ICP备2023020795号-1
ghs 京公网安备 11010802042870号
Book学术文献互助
Book学术文献互助群
群 号:604180095
Book学术官方微信