{"title":"An analytical methodology for the determination of cadmium bound to whey-proteins by laser-induced breakdown spectroscopy at low pressures.","authors":"İlayda Yaman Erdoğrul, Şerife H Yalçın","doi":"10.1016/j.talanta.2025.128537","DOIUrl":null,"url":null,"abstract":"<p><p>In this study, a dried-droplet LIBS methodology for determining cadmium in cow milk has been developed. The performance of the methodology was shown by standard and real protein samples. A standard protein, bovine serum albumin (BSA), and whey protein extracted from skim cow milk were incubated in standard Cd solutions, and the complex solution was filtered through cut-off filters by centrifugation. The unreacted cadmium in the filtrate and Cd-bound protein in the filtered fraction were loaded separately onto a Si-wafer substrate and analyzed via dried-droplet LIBS methodology. Measurements were performed at reduced pressures by taking advantage of the signal enhancement effect. The optimum pressure for most Cd emission lines was found to be 100 mbar. It has been shown that the dried-droplet LIBS methodology at reduced pressures can be used for the identification and determination of free and protein-bound Cd in the whey matrix. The concentration-based detection limit of Cd bound to whey proteins was determined to be 20.2 ng mL<sup>-1</sup>, which corresponds to as low as 10 pg in absolute amount with a sample volume of 500 nL. The LOQ value is estimated as 67.3 ng mL<sup>-1</sup> and 33.3 pg, in terms of concentration unit and absolute amount, respectively. The use of small sample volumes is important in the analysis of limited amounts of samples, such as body fluids. Preconcentration studies with multiple loadings of the sample on the same spot resulted in improvements in concentration-based detection. 8 ng mL<sup>-1</sup> Cd in the whey matrix that could not be determined by a single droplet loading due to being below the detection limit; could be determined after 10 consecutive loadings. The methodology may also be applied to the determination of other toxic metals bound to proteins for food quality control.</p>","PeriodicalId":435,"journal":{"name":"Talanta","volume":"296 ","pages":"128537"},"PeriodicalIF":6.1000,"publicationDate":"2026-01-01","publicationTypes":"Journal Article","fieldsOfStudy":null,"isOpenAccess":false,"openAccessPdf":"","citationCount":"0","resultStr":null,"platform":"Semanticscholar","paperid":null,"PeriodicalName":"Talanta","FirstCategoryId":"92","ListUrlMain":"https://doi.org/10.1016/j.talanta.2025.128537","RegionNum":1,"RegionCategory":"化学","ArticlePicture":[],"TitleCN":null,"AbstractTextCN":null,"PMCID":null,"EPubDate":"2025/6/30 0:00:00","PubModel":"Epub","JCR":"Q1","JCRName":"CHEMISTRY, ANALYTICAL","Score":null,"Total":0}
引用次数: 0
Abstract
In this study, a dried-droplet LIBS methodology for determining cadmium in cow milk has been developed. The performance of the methodology was shown by standard and real protein samples. A standard protein, bovine serum albumin (BSA), and whey protein extracted from skim cow milk were incubated in standard Cd solutions, and the complex solution was filtered through cut-off filters by centrifugation. The unreacted cadmium in the filtrate and Cd-bound protein in the filtered fraction were loaded separately onto a Si-wafer substrate and analyzed via dried-droplet LIBS methodology. Measurements were performed at reduced pressures by taking advantage of the signal enhancement effect. The optimum pressure for most Cd emission lines was found to be 100 mbar. It has been shown that the dried-droplet LIBS methodology at reduced pressures can be used for the identification and determination of free and protein-bound Cd in the whey matrix. The concentration-based detection limit of Cd bound to whey proteins was determined to be 20.2 ng mL-1, which corresponds to as low as 10 pg in absolute amount with a sample volume of 500 nL. The LOQ value is estimated as 67.3 ng mL-1 and 33.3 pg, in terms of concentration unit and absolute amount, respectively. The use of small sample volumes is important in the analysis of limited amounts of samples, such as body fluids. Preconcentration studies with multiple loadings of the sample on the same spot resulted in improvements in concentration-based detection. 8 ng mL-1 Cd in the whey matrix that could not be determined by a single droplet loading due to being below the detection limit; could be determined after 10 consecutive loadings. The methodology may also be applied to the determination of other toxic metals bound to proteins for food quality control.
本研究建立了一种测定牛奶中镉的干滴LIBS方法。通过标准蛋白和真实蛋白样品验证了该方法的有效性。从脱脂牛奶中提取标准蛋白、牛血清白蛋白(BSA)和乳清蛋白,在标准Cd溶液中孵育,并通过离心切断过滤器过滤。滤液中未反应的镉和过滤后的cd结合蛋白分别被加载到硅片衬底上,并通过干滴LIBS方法进行分析。利用信号增强效应,在减压下进行测量。发现大多数Cd发射线的最佳压力为100毫巴。研究表明,减压下的干滴LIBS方法可用于乳清基质中游离Cd和蛋白结合Cd的鉴定和测定。乳清蛋白结合Cd的浓度检测限为20.2 ng mL-1,在500 nL的样品体积下,其绝对含量可低至10 pg。LOQ值以浓度单位计算为67.3 ng mL-1,以绝对数量计算为33.3 pg。在分析有限数量的样品(如体液)时,使用小样本量很重要。在同一地点多次装载样品的预浓缩研究改善了基于浓度的检测。乳清基质中Cd含量为8 ng mL-1,低于检出限,单滴加载无法检测;可在连续加载10次后确定。该方法也可用于其它与蛋白质结合的有毒金属的测定,用于食品质量控制。
期刊介绍:
Talanta provides a forum for the publication of original research papers, short communications, and critical reviews in all branches of pure and applied analytical chemistry. Papers are evaluated based on established guidelines, including the fundamental nature of the study, scientific novelty, substantial improvement or advantage over existing technology or methods, and demonstrated analytical applicability. Original research papers on fundamental studies, and on novel sensor and instrumentation developments, are encouraged. Novel or improved applications in areas such as clinical and biological chemistry, environmental analysis, geochemistry, materials science and engineering, and analytical platforms for omics development are welcome.
Analytical performance of methods should be determined, including interference and matrix effects, and methods should be validated by comparison with a standard method, or analysis of a certified reference material. Simple spiking recoveries may not be sufficient. The developed method should especially comprise information on selectivity, sensitivity, detection limits, accuracy, and reliability. However, applying official validation or robustness studies to a routine method or technique does not necessarily constitute novelty. Proper statistical treatment of the data should be provided. Relevant literature should be cited, including related publications by the authors, and authors should discuss how their proposed methodology compares with previously reported methods.